The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1901–1925 of 5111

  • SevereFDA (Devices)·Z-0346-2022·2021-12-15

    Puritan Bennett 980 Series Ventilator Recalled for Capacitor Assembly Defect

    Covidien is recalling 278 Puritan Bennett 980 Series Ventilators (Model 980X1ENDIPC) due to incorrect capacitor assembly that may cause the device to malfunction during use.

    Product
    Puritan Bennett 980 Series Ventilator, 980X1ENDIPC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0349-2022·2021-12-15

    Puritan Bennett 980 Series Ventilator recalled for assembly defect

    Puritan Bennett 980 Series Ventilators are recalled due to a capacitor assembly error that may cause the device to become inoperable during use. The recall affects 278 units distributed worldwide.

    Product
    Puritan Bennett 980 Series Ventilator, 980X1JADIJJ
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0232-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device Catheter Lumen Detachment Recall

    Arrow International is recalling Arrow-Trerotola Percutaneous Thrombolytic Device catheters because the inner lumen can detach from the device basket, causing embolization requiring additional intervention and delaying dialysis therapy. Approximately 1,245 units are affected worldwide.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-65709-HFWC The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-veno
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0224-2022·2021-11-24

    FDA Recalls Scrip Ultrasound Gel for Potential Bacterial Contamination

    Scrip Inc is recalling Scrip Ultrasound Gel Clear (5L) nationwide due to potential bacterial contamination. Affected units may cause harm if contaminated product contacts patients during ultrasound procedures.

    Product
    Scrip Ultrasound Gel Clear, 5L Intended for use in acoustic coupling of ultrasound transducer to tissue
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0225-2022·2021-11-24

    Scrip Creme ultrasound lotion recalled for bacterial contamination

    Scrip Creme All Purpose Lotion is being recalled due to bacterial contamination in this ultrasound coupling lotion. The product—1001 gallons in lots distributed between August 2018 and August 2021—was distributed nationwide.

    Product
    Scrip Creme All Purpose Lotion Intended for use in acoustic coupling of ultrasound transducer to tissue
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0231-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device Inner Lumen Detachment Recall

    The inner lumen of Arrow-Trerotola Over-The-Wire PTD catheters (7FR) can detach from the device, causing an embolism. This requires additional medical intervention and delays treatment.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-12709-WC The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venous
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0233-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device inner lumen detachment and embolization risk

    Arrow-Trerotola PTD catheters are being recalled because the inner lumen can detach from the device basket, causing embolization that requires additional intervention. 1,167 units are affected.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-65709-W The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venousf
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0234-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device: Inner Lumen Detachment Risk

    Arrow International is recalling 1918 units of the Arrow-Trerotola Percutaneous Thrombolytic Device due to inner lumen detachment that can cause embolization, requiring emergency retrieval and delaying treatment.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-65709-WC The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venous
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0183-2022·2021-11-17

    Ellume COVID-19 Home Test Recalled for Higher Rate of False Positives

    Ellume recalled approximately 427,994 COVID-19 home test kits due to a higher rate of false positive results. The affected kits were distributed in Minnesota, New York, Pennsylvania, Rhode Island, Utah, and Washington.

    Product
    Ellume COVID-19 Home Test
    Category
    Medical Device
    Distribution
    6 states
  • SevereFDA (Devices)·Z-0119-2022·2021-11-10

    Monoject Prefilled Syringe Plunger Defect Recall: Air Reintroduction Risk

    Monoject prefilled syringes in medical kits may have a plunger that rebounds after air expulsion, potentially reintroducing air into the syringe. This FDA Class I recall affects approximately 9,378 units distributed in Florida and Pennsylvania.

    Product
    Monoject 0.9% Sodium Chloride, Flush Prefilled Syringe, 10 mL, REF: 8881570121 inside the following Aligned Medical Solutions Custom Convenience Kits: AMS-9041CP Leaderflex Insertion Kit with Ultrasound, AMS-9046CP-1 Insertion Tray-RX, AMS8939A Universal Procedure Pack w/Sp
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-0194-2022·2021-11-10

    IPL Coupling Gel and EcoGel 200 Recalled for Bacterial Contamination

    Lumenis, Inc. is recalling IPL Coupling Gel and EcoGel 200 due to potential bacterial contamination. Approximately 11,064 units were distributed worldwide.

    Product
    IPL Coupling Gel, I L (AX1009013), 12 pack of 0.25 L (AX1009018), 6 pack of 1 L (AX1009019 or AX1009063); and IPL Coupling Gel or EcoGel 200, 0.25 L (AX1009012) manufactured by Eco-Med Pharmaceutical
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0118-2022·2021-11-03

    Surgical Brain Guidance System Recalled for Inaccurate Electrode Placement

    ROSA One 3.1 surgical guidance system recalled due to a software anomaly causing inaccurate electrode placement during brain and spine surgery. Manufacturer received 3 complaints related to the issue.

    Product
    ROSA One 3.1 Brain application The device is intended for the spatial positioning and orientation of instruments holders or tool guides to be used by trained surgeons to guide standard surgical instruments during brain and spine surgeries.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0091-2022·2021-10-27

    Cardiosave Li-Ion battery pack recalled for insufficient runtime specification

    Datascope Corp. is recalling Cardiosave Li-Ion battery packs that failed to meet minimum runtime requirements. These nonconforming batteries were inadvertently released to customers worldwide.

    Product
    Cardiosave Li-Ion Battery Pack, Part No. 0146-00-0097. Component of the Cardiosave Hybrid Intra-Aortic Balloon Pump (IABP) with the below Model Numbers. 1. Cardiosave Hybrid. Model Numbers: 0998-00-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-00-0800-35, 0998-00-0800-36, 099
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0107-2022·2021-10-27

    Infusion Pump Air Detector Malfunction May Prevent Alarm to Clinician

    Smiths Medical CADD-Solis VIP ambulatory infusion pumps may fail to detect air in the infusion line and alert clinicians due to intermittent air-detector malfunction.

    Product
    CADD-Solis VIP ambulatory infusion pump, Model Numbers: a. 21-2120-0105-02L b. 21-2120-0105-03L c. 21-2120-0105-06L d. 21-2120-0105-07L e. 21-2120-0105-08L f. 21-2120-0105-12L g. 21-2120-0105-13L h. 21-2120-0105-14L i. 21-2120-0105-15L j. 21-2120-0105-17L k. 21-2120-01
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0088-2022·2021-10-20

    Eco-Med Ultrasound Gel Recalled for Bacterial Contamination Risk

    Eco-Med Pharmaceutical's ultrasound gel products are recalled due to potential bacterial contamination. The FDA advises healthcare providers to stop using the affected product.

    Product
    EcoGel 200 - RED Medical Supplies Blue Ultrasound Gel, Model No. 250UG-BMU
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0089-2022·2021-10-20

    FDA recalls Eco-Med ultrasound gels due to bacterial contamination risk

    FDA recalls ultrasound gels manufactured by Eco-Med Pharmaceutical due to possible bacterial contamination. Healthcare providers and facilities should stop use immediately.

    Product
    EcoGel 200 - RED Medical Supplies Clear Ultrasound Gel, Model No. 250UG-CMU
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0004-2022·2021-10-20

    Abbott SARS-CoV-2 Diagnostic Kit Recalled for Risk of False Positive Results

    Abbott Molecular is recalling 60,563 units of the Alinity m SARS-CoV-2 Amp Kit due to potential false positive test results. The affected kits were distributed worldwide from September 2021 through January 2023.

    Product
    Alinity m SARS-CoV-2 Amp Kit (Emergency Use Authorization, US Assay) and Alinity m SARS-CoV-2 Application Specification File. in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0005-2022·2021-10-20

    Abbott Alinity m Resp-4-Plex Respiratory Diagnostic Kit Recalled for False Positive Results

    Abbott is recalling the Alinity m Resp-4-Plex AMP Kit, an in vitro diagnostic used for respiratory pathogen testing, due to potential for false positive results affecting approximately 8,469 units distributed worldwide.

    Product
    Alinity m Resp-4-Plex AMP Kit (Emergency Use Authorization, US Assay) and Alinity m Resp-4-Plex Application Specification File. in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0008-2022·2021-10-20

    Abbott Respiratory Diagnostic Kit Recalled for Potential False Positive Results

    Abbott Molecular is recalling the Alinity m Resp-4-Plex AMP Kit due to potential false positive results. The recall affects 5,855 units distributed worldwide.

    Product
    Alinity m Resp-4-Plex AMP Kit (Non-US Assay) and Alinity m Resp-4-Plex Application Specification File. in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0006-2022·2021-10-20

    Abbott Alinity m SARS-CoV-2 Amp Kit Recalled for Potential False Positive Results

    Abbott Molecular has recalled 71,314 units of the Alinity m SARS-CoV-2 Amp Kit due to potential false positive results. The kit was distributed worldwide.

    Product
    Alinity m SARS-CoV-2 Amp Kit (Non-US Assay) and Alinity m SARS-CoV-2 Application Specification File. in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0007-2022·2021-10-20

    Abbott Alinity m SARS-CoV-2 Test Kit Recalled for Potential False Positives

    Abbott Molecular recalls its Alinity m SARS-CoV-2 Amp Kit (Non-US Assay), an in vitro diagnostic test, due to potential for false positive results. Approximately 11,408 units were distributed worldwide.

    Product
    Alinity m SARS-CoV-2 Amp Kit (Non-US Assay) and Alinity m SARS-CoV-2 Application Specification File. in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0090-2022·2021-10-20

    FDA Recalls Ultrasound Gel for Possible Bacterial Contamination

    Red Medical Supplies is recalling EcoGel 100 ultrasound gel due to possible bacterial contamination. Approximately 639 units were sold nationwide through Amazon.com.

    Product
    EcoGel 100 - RED Medical Supplies Green Ultrasound Gel, Model No. 250UG-GLU
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0067-2022·2021-10-20

    FDA Recalls Ultrasound Gels and Lotions for Potential Bacterial Contamination

    Ultrasound gels and lotions from National Distribution & Contracting Inc are being recalled due to potential bacterial contamination. About 25,103 units distributed nationwide and in Canada are affected.

    Product
    ECO 85CB Lotion Ultrasound 8.5 oz 24/cs ECO 40JBC Gel Ultrasound Transmission Clr 8.5 oz BTL 24/cs ECO 40JMC Gel Ultrasound Transmission Clr 5L 4/cs NDC P301008 ProAdvantage Gel Ultrasound Transmission 8.5 oz 12/cs NDC P301105 ProAdvantage Gel Ultrasound Transmission 5 Liter
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0068-2022·2021-10-20

    Ultrasound gel products recalled for potential bacterial contamination

    Ultrasound gels and lotions manufactured by Eco-Med Pharmaceutical, Inc. may contain bacterial contamination. Products distributed nationwide in the U.S., Canada, and other locations have been recalled.

    Product
    ECO 50TS Gel Tens Ultrasound 1in X 5L cube 1 Dispenser Btl
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0009-2022·2021-10-13

    Ultrasound gel distributed with medical devices recalled for bacterial contamination

    Ultrasound gel manufactured by Eco-Med Pharmaceutical and distributed with various medical device kits may contain bacterial contamination. Users should stop using affected products and follow FDA guidance.

    Product
    GEL CONDUCTOR, Description/REF: 5 LITER W/DISP/4238, 24-8.5OZ BOTTLES/4248, 5 LITER/4266, distributed by DJO, LLC / DJO FRANCE in the following kits, Part/Description: 2073/ INTELECT RPW 120V, 2073-BR/ INTELECT RPW 120V BRAZIL, 2074/ INTELECT RPW 230 V, 20
    Category
    Medical Device
    Distribution
    Distributed nationwide