The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

17026–17050 of 27500

  • HighFDA (Devices)·Z-2759-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensor Catheters Due to Defective Sensors

    Degania Silicone is recalling 1,028 temperature sensor catheters because defective sensors may display lower body temperatures than actual.

    Product
    Temperature Sensor Catheter 12FR, Catalogue Number 102201101263BI Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary bladder…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3181-2018·2018-09-26

    Stryker Recalls IsoFlex LAL Support Surfaces Due to Fire Barrier Defect

    Stryker is recalling 243 IsoFlex LAL support surfaces because they were assembled with a non-conforming fire barrier. The units were distributed in five US states.

    Product
    IsoFlex LAL Support Surface, Model Number 2860 Product Usage: : The IsoFlex LAL support surface assists in the prevention and treatment of all pressure injuries (including stages 1,2,3,4, unstageable injury, and deep tissue injury) and is recommended to be implemented in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2996-2018·2018-09-26

    Ventana OptiView DAB IHC Detection Kit Recalled for Leaking Dispensers

    Ventana Medical Systems is recalling OptiView DAB IHC Detection Kits because leaking dispensers may cause false negative test results.

    Product
    OptiView DAB IHC Detection Kit, Catalog Number 06396500001, model 760-700 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2758-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensor Foley Catheters Due to Defective Sensors

    Degania Silicone is recalling 475 Temperature Sensor Foley Catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Temperature Sensor Catheter 10FR, Catalogue Number 102201101063BI Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary bladder…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2785-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensing Foley Catheters Due to Defective Sensors

    Degania Silicone, Ltd. is recalling 1,000 temperature sensing Foley catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Temperature sensing catheter 16FR, Catalogue Number 102201101663NU Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary bladder…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3004-2018·2018-09-26

    Ventana ultraView Universal Alkaline Phosphatase Red Detection Kit Recalled

    Ventana Medical Systems is recalling 8,211 units of the ultraView Universal Alkaline Phosphatase Red Detection Kit due to leaking and sticking dispensers that may cause false negative IHC results.

    Product
    ultraView Universal Alkaline Phosphatase Red Detection Kit, Catalog Number 05269814001, model 760-501 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-3203-2018·2018-09-26

    Coviden Recalls Defective Temperature Sensing Foley Catheters

    Coviden is recalling specific sterile Foley catheter trays because the temperature sensors may display lower body temperature readings than the patient's actual temperature.

    Product
    400mL, Premium, Urine Meter, 16 FR, Silicone Temperature Sensing Foley Traywith Cath-Secure Plus, Sterile, Item Code P4P16XTSD
    Category
    Medical Device
    Distribution
    24 states
  • HighFDA (Devices)·Z-2770-2018·2018-09-26

    Degania Foley Temperature Sensor Catheters Recalled for Defective Sensors

    Degania Silicone is recalling 250 Foley Temperature Sensor Catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Foley Temperature Sensor Catheter 12FR, Catalogue Number 102201101280JP Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2778-2018·2018-09-26

    Degania Silicone Recalls Thermistor Foley Catheters Due to Defective Sensors

    Degania Silicone is recalling 14,326 Thermistor Foley catheters because defective sensors may display inaccurate, lower body temperature readings.

    Product
    Thermistor Foley catheter, nonsterile, Catalogue Number 102201101663MD Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3007-2018·2018-09-26

    Ventana CONFIRM anti-Estrogen Receptor Antibody Recalled for Dispenser Defects

    Ventana Medical Systems is recalling CONFIRM anti-Estrogen Receptor antibodies due to leaking and sticking dispensers that may cause false negative IHC results.

    Product
    CONFIRM anti-Estrogen Receptor (ER) (SP1) Rabbit Monoclonal Primary Antibody, Catalog Number 05278414001, Model 790-4325 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2761-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensor Catheters Due to Defective Sensors

    Degania Silicone is recalling 16,133 temperature sensor catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Temperature Sensor Catheter 16FR, Catalogue Number 102201101663BI Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary bladder…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2766-2018·2018-09-26

    Degania Foley Catheters Recalled Due to Defective Temperature Sensors

    Degania Silicone is recalling Foley catheters with temperature sensors because defective units may display lower body temperatures than actual.

    Product
    Foley Catheter with temperature sensor 400TM 16FR, Catalogue Number 102201101680TY Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3002-2018·2018-09-26

    Ventana iVIEW Blue Plus Detection Kit Recalled for Dispenser Leaks

    Ventana Medical Systems is recalling iVIEW Blue Plus Detection Kits because leaking dispensers may cause false negative IHC results.

    Product
    ISH iVIEW Blue Plus Detection Kit, Catalog Number 05266181001, model 760-097 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2997-2018·2018-09-26

    Ventana ultraView Universal DAB Detection Kit Recalled for Dispenser Defects

    Ventana Medical Systems is recalling ultraView Universal DAB Detection Kits due to leaking and sticking reagent dispensers that may cause false negative IHC results.

    Product
    ultraView Universal DAB Detection Kit, Catalog Number 05269806001, model 760-500 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-3013-2018·2018-09-26

    Ventana Medical Systems Recalls Leaking CINtec p16 Histology Reagent Dispensers

    Ventana Medical Systems is recalling 240 units of CINtec p16 Histology reagent dispensers due to leaking and sticking issues that may cause false negative test results.

    Product
    CINtec p16 Histology (250) CE, Catalog Number 06695256001, model 825-4713 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-3201-2018·2018-09-26

    Medtronic Recalls Contour Plus Link 2.4 Meters with Incorrect Units

    Medtronic is recalling two Contour Plus Link 2.4 meters distributed in Slovakia that display glucose in mg/dL instead of mmol/L.

    Product
    Contour Plus Link 2.4, Product Catalog Number: MMT-1151SK. wireless blood glucose monitoring system Contour Plus LINK 2.4 wireless blood glucose monitoring system (glucometer, test strips and control solution) is designed for self-testing by persons with diabetes and the…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-3009-2018·2018-09-26

    Ventana Basal Cell IHC Reagent Recall Due to Dispenser Defects

    Ventana Medical Systems is recalling 75 units of Basal Cell IHC reagents due to leaking and sticking dispensers that may cause false negative results.

    Product
    VENTANA Basal Cell Cktl, (34BE12+p63)250, Catalog Number 06419445001, Model 790-1010 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-3016-2018·2018-09-26

    Ventana ultraView SISH DNP Detection Kit Recalled for Leaking Dispensers

    Ventana Medical Systems is recalling 342 units of the ultraView SISH DNP Detection Kit because leaking dispensers may cause false negative IHC results.

    Product
    ultraView SISH DNP Detection Kit, Catalog Number 05907136001, model 800-098 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-3132-2018·2018-09-19

    Zimmer Biomet Recalls Affixus Hip Fracture Nail Due to Set Screw Defect

    Zimmer Biomet is recalling 5,947 Affixus Hip Fracture Nails because the set screw cannot advance or reverse from its original position.

    Product
    Affixus¿ Hip Fracture Nail 130¿ 13 mm x 180 mm, Item Number: 814513180
    Category
    Medical Device
    Distribution
    42 states
  • SevereFDA (Devices)·Z-3074-2018·2018-09-19

    Zimmer Biomet Recalls Affixus Hip Fracture Nail Due to Set Screw Defect

    Zimmer Biomet is recalling Affixus Hip Fracture Nails because the set screw cannot advance or reverse from its original position.

    Product
    Affixus¿ Hip Fracture Nail Right 125¿ 13 mm x 400 mm, Item Number: 814313400
    Category
    Medical Device
    Distribution
    42 states
  • SevereFDA (Devices)·Z-3161-2018·2018-09-19

    Zimmer Biomet Recalls Affixus Hip Fracture Nail Due to Set Screw Defect

    Zimmer Biomet is recalling Affixus Hip Fracture Nails because the set screw cannot advance or reverse from its original position.

    Product
    Affixus¿ Hip Fracture Nail Left 130¿ 11 mm x 440 mm, Item Number: 814611440
    Category
    Medical Device
    Distribution
    42 states