The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

16976–17000 of 27500

  • SevereFDA (Devices)·Z-2999-2018·2018-09-26

    Ventana Medical Systems Recalls ultraView SISH DNP Detection Kit Due to Leaking

    Ventana Medical Systems is recalling 96 units of the ultraView SISH DNP Detection Kit because leaking and sticking dispensers may cause false negative IHC results.

    Product
    ultraView SISH DNP Detection Kit US, Catalog Number 05572037001, model 760-098 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2754-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensor Foley Catheters Due to Defective Sensors

    Degania Silicone is recalling 153 temperature sensor Foley catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Temperature sensor Foley catheter 18FR, Catalogue Number 102205101880AB Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3205-2018·2018-09-26

    Coviden Temperature Sensing Foley Catheters Recalled for Inaccurate Readings

    Coviden is recalling temperature sensing Foley catheters that may display lower body temperature measurements than the patient's actual temperature.

    Product
    400mL, Premium, Urine Meter, 14 FR, Silicone Temperature Sensing Foley Traywith Cath-Secure Plus, Sterile, Item Code P4P14TSD
    Category
    Medical Device
    Distribution
    24 states
  • HighFDA (Devices)·Z-3003-2018·2018-09-26

    Ventana Anti-Pan Keratin Antibody Recalled for Leaking and Sticking Dispensers

    Ventana Medical Systems is recalling 354 units of Anti-Pan Keratin Primary Antibody due to leaking and sticking dispensers that may cause false negative IHC results.

    Product
    ANTI-PAN Keratin Primary Antibody, 25 mL, Catalog Number 05266840001, model 760-2135 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2998-2018·2018-09-26

    Ventana iView DAB Detection Kit Recalled for Leaking and Sticking Dispensers

    Ventana Medical Systems is recalling iView DAB Detection Kits due to leaking and sticking reagent dispensers that may cause false negative immunohistochemistry results.

    Product
    iView DAB Detection Kit, Catalog Number 05266157001, model 760-091 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2765-2018·2018-09-26

    Degania Silicone Recalls Foley Catheters with Defective Temperature Sensors

    Degania Silicone is recalling 89,122 Foley catheters with temperature sensors because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Foley Catheter with temperature sensor 400TM 14FR, Catalogue Number 102201101480TY Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3202-2018·2018-09-26

    ShinChang Recalls Disposable Insulin Syringes Due to Barrel Cracks

    ShinChang Medical Co., Ltd. is recalling 6,570,800 disposable insulin syringes because a small crack was found in the top end of the barrel near the needle.

    Product
    Disposable Insulin Syringe 0.3mL in 3 different sizes 29Gx1/2, 30Gx5/16, and 31G x 5/16. (10 syringes are packaged in a flexible plastic (poly bag) and 10 flexible plastic (poly bag) are packaged in one in box. Finally, pack the inboxes in the carton case.)
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-3188-2018·2018-09-26

    EOS Imaging Recalls sterEOS Workstation Due to 3D Projection Errors

    EOS Imaging is recalling 17 sterEOS workstations because 3D projections may be incorrect when using specific secondary image captures, potentially leading to clinical errors.

    Product
    sterEOS workstation
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2763-2018·2018-09-26

    Degania Silicone Recalls Foley Catheters with Defective Temperature Sensors

    Degania Silicone is recalling 4,332 Foley catheters with temperature sensors because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Foley Catheter with temperature sensor 400TM 8FR, Catalogue Number 102201100880TY Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3180-2018·2018-09-26

    bioMerieux Recalls VITEK 2 AST-P655 Cards Due to Gentamicin Error

    bioMerieux is recalling VITEK 2 AST-P655 cards because six lots were manufactured with insufficient gentamicin, potentially affecting high-level resistance screening results.

    Product
    VITEK(R) 2 AST-P655, For susceptibility testing of Staphylococcus spp. Enterococcus spp., ad S agalactiae against specified antimicrobials, REF 421913 Product Usage: VITEK¿ 2 is an automated system consisting of instruments, software and reagent cards designed for the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2779-2018·2018-09-26

    Degania Silicone Recalls Thermistor Foley Catheters Due to Defective Sensors

    Degania Silicone is recalling 330 Thermistor Foley catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Thermistor Foley catheter, nonsterile, Catalogue Number 102201100863MD Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2756-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensor Foley Catheters Due to Defective Sensors

    Degania Silicone is recalling 500 units of temperature sensor Foley catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Temperature sensor Foley catheter 10FR, Catalogue Number 102205101080AB Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3195-2018·2018-09-26

    Fresenius 2008T Hemodialysis System Recalled for Disinfectant Exposure Risk

    Fresenius Medical Care is recalling 40 units of the 2008T Hemodialysis System because a power failure during cleaning could leave disinfectant in the dialysate delivered to patients.

    Product
    2008T HEMODIALYSIS SYSTEM W/BIBAG, Part Number 190766, Applicable only with 2008T BlueStar Premium Upgrade Kit, Part Number 191138 Product Usage: Indicated for acute and chronic dialysis therapy.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3178-2018·2018-09-26

    Permobil Recalls Powered Wheelchairs Due to Backrest Bar Failure Risk

    Permobil is recalling 3,134 powered wheelchairs because backrest support bars may fail, potentially causing users to fall backward and sustain injuries.

    Product
    Permobil powered wheelchairs, Model Numbers: (a) M300 PS, (b) C300 PS, (c) C350 PS, (d) C500 PS, (e) C400 PS Product Usage: The devices identified are intended to provide outdoor and indoor mobility to persons limited to a seated position that can operate a powered…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2769-2018·2018-09-26

    Degania Foley Temperature Sensor Catheters Recalled for Defective Sensors

    Degania Silicone is recalling 250 Foley Temperature Sensor Catheters because defective sensors may display lower body temperatures than actual.

    Product
    Foley Temperature Sensor Catheter 10FR, Catalogue Number 102201101080JP Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3206-2018·2018-09-26

    Coviden Temperature Sensing Foley Catheters Recalled for Inaccurate Readings

    Coviden is recalling temperature sensing Foley catheters because they may display lower body temperature readings than the patient's actual temperature.

    Product
    400mL, Premium, Urine Meter, 16 FR, Silicone Temperature Sensing Foley Traywith Cath-Secure Plus, Sterile, Item Code P4P16TSD
    Category
    Medical Device
    Distribution
    24 states
  • HighFDA (Devices)·Z-2783-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensing Foley Catheters Due to Defective Sensors

    Degania Silicone is recalling 2,461 temperature sensing Foley catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Temperature sensing catheter 18FR, Catalogue Number 102203101863DO Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary bladder…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2971-2018·2018-09-26

    Pro-Med Instruments Recalls DORO LUCENT Locking Transitional Member

    Pro-Med Instruments is recalling 31 DORO LUCENT Locking Transitional Members because mixing design revisions may cause the headrest system to malfunction.

    Product
    DORO LUCENT Locking Transitional Member, REF 1101.031 Component of headrest system used in open and percutaneous craniotomies and spinal surgeries
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-2774-2018·2018-09-26

    Degania Silicone Foley Catheters Recalled for Defective Temperature Sensors

    Degania Silicone is recalling 500 units of temperature-sensing Foley catheters because defective sensors may display inaccurate, lower body temperature readings.

    Product
    Temperature Sensing 100% Silicone Foley Catheter, sterile, Catalogue Number 102201101880MD Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2772-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensing Foley Catheters Due to Defective Sensors

    Degania Silicone, Ltd. is recalling 1,000 temperature sensing Foley catheters because defective sensors may display lower body temperatures than actual.

    Product
    Temperature Sensing 100% Silicone Foley Catheter, sterile, Catalogue Number 102201100880MD Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3210-2018·2018-09-26

    Medline Recalls Endoscopic Cleaning Brushes Due to Detachment Risk

    Medline Industries is recalling single-use endoscopic cleaning brushes because they may detach during cleaning, potentially leaving parts inside the scope.

    Product
    Endoscopic Cleaning Brush, single use, sold in kits and labeled as the following: a. Item Number DYK1002DCB, BRUSH, CLEANING, DOUBLE ENDED, W/ HANDLE - 300 EA/CS, 50EA/BX, 6BX/CS; b. Item Number DYK1002DBDE, BRUSH, CLEANING, DBL, DIF ENDS - 500 EA/CS, 50 EA/BX, 10…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3014-2018·2018-09-26

    Ventana Medical Systems Recalls Leaking HPV III Probe Dispensers

    Ventana Medical Systems is recalling 195 units of the INFORM HPV III Fam 16 Probe due to leaking and sticking dispensers that may cause false negative test results.

    Product
    INFORM HPV III Fam 16 Probe - US Export, Catalog Number 05278856001, model 800-4295 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2782-2018·2018-09-26

    Degania Silicone Recalls Temperature Sensing Foley Catheters Due to Defective Sensors

    Degania Silicone is recalling 34,627 temperature sensing Foley catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Temperature sensing catheter 16FR, Catalogue Number 102203101663DO Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary bladder…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2771-2018·2018-09-26

    Degania Foley Temperature Sensor Catheters Recalled for Defective Sensors

    Degania Silicone is recalling Foley Temperature Sensor Catheters because defective sensors may display lower body temperatures than the patient's actual temperature.

    Product
    Foley Temperature Sensor Catheter 14FR, Catalogue Number 102201101480JP Product Usage: This is sterile, single use, two-way silicone Foley Catheter with a thermistor embedded in the third lumen. It is intended for use in the drainage/ collection of urine from the urinary…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3005-2018·2018-09-26

    Ventana ISH Protease 3 Reagent Recall for Leaking and Sticking Dispensers

    Ventana Medical Systems is recalling ISH Protease 3 reagents due to leaking and sticking dispensers that may cause false negative IHC results.

    Product
    ISH Protease 3, Catalog Number 05273331001, model 780-4149 Immunohistochemistry (IHC) for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    0 states