The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

12951–12975 of 27500

  • SevereFDA (Devices)·Z-0049-2021·2020-10-07

    Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 9,214 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile, posing a risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 3/0 Undyed 30" C-13 Cutting SV2298, UDI: 20884521151021 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for use in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0034-2021·2020-10-07

    Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 1,811 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile. The defect could compromise the sterile field and increase the risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 1 Undyed 36" GS-25, Product Number: CV605, UDI: 20884521152295 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for use…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-3052-2020·2020-10-07

    ESAOTE AC/DC Power Supply Recall for Portable Ultrasound Systems

    ESAOTE is recalling AC/DC power adapters for specific portable ultrasound systems because the connector may heat up, smoke, or melt due to mechanical stress.

    Product
    AC/DC POWER SUPPLY for 7400, Part Number 151004300, XP Power Model Number AHM180PS19-XE0338, AC/DC Adapter associated with the following portable ultrasound diagnostic systems: The AC/DC adapter is intended for use with the following portable ultrasound systems: MyLabAlpha…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0008-2021·2020-10-07

    Endo GIA Stapler Recall Due to Incomplete Staple Formation

    FDA recalls Endo GIA Auto Suture staplers because staples may not form properly, potentially preventing adequate hemostasis during surgery.

    Product
    Endo GIA Auto Suture Universal Articulating Loading Unit 60 mm - 3.5 mm, Item Code 030458 - Product Usage: The Endo GIA universal staplers have applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection and creation of anastomosis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0044-2021·2020-10-07

    Riverpoint Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 1,266 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile. The defect could compromise the sterile field and increase the risk of surgical site infections.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 3/0 Undyed 18" P-12 Cutting SV497G, UDI: 20884521149707 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for use in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0033-2021·2020-10-07

    Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 1,276 units of Velosorb Fast Braided Absorbable Sutures because the product is non-sterile. This condition could compromise the sterile field and increase the risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 3/0 Undyed 36" KV-34, TaperCutting Product Number: CV916, UDI: 20884521153032 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0028-2021·2020-10-07

    Riverpoint Recalls Non-Sterile Velosorb Fast Braided Absorbable Sutures

    Riverpoint Medical is recalling 1,248 units of non-sterile Velosorb sutures due to a risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 5/0 Undyed 30" CV-23 Taper, Product Number: CV1213, UDI: 20884521150758 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0003-2021·2020-10-07

    Endo GIA Stapler Recall Due to Incomplete Staple Formation

    FDA is recalling Endo GIA Auto Suture Universal Articulating Loading Units because staples may not form properly, potentially preventing adequate hemostasis during surgery.

    Product
    Endo GIA Auto Suture Universal Articulating Loading Unit 30 mm - 3.5 mm, Item Code 030452 - Product Usage: The Endo GIA universal staplers have applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection and creation of anastomosis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0012-2021·2020-10-07

    Riverpoint Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling non-sterile Velosorb sutures that could increase the risk of surgical site infections.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 4/0 Undyed 30" P-12 Cutting, Product Number: SV426, UDI: 20884521151731 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0017-2021·2020-10-07

    Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 1,258 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile, posing a risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 4/0 Undyed 18" P-24, Product Number: SV9911G, UDI: 20884521149776 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0016-2021·2020-10-07

    Riverpoint Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 3,110 units of non-sterile Velosorb sutures because they may compromise the sterile field and increase infection risk.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 3/0 Undyed 18" P-14 Cutting, Product Number: SV6830, UDI: 20884521152349 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0023-2021·2020-10-07

    Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling non-sterile Velosorb Fast Braided Absorbable Sutures because they may compromise the sterile field and increase the risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 6/0 Undyed 30" P-10 Cutting, Product Number: SV4893, UDI: 20884521151717 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0047-2021·2020-10-07

    Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 7,982 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile, posing a risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 3/0 Undyed 30" CV-25 Taper CV3110, UDI: 20884521150918 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for use in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3026-2020·2020-10-07

    Zeus ELISA Parvovirus B19 IgM Test System Recalled for False Positives

    Zeus Scientific is recalling 74 units of the ZEUS ELISA Parvovirus B19 IgM Test System due to false positive results identified during an FDA inspection.

    Product
    ZEUS ELISA Parvovirus B19 IgM Test System, UDI 00845533001755 - Product Usage: intended for the qualitative detection of IgM class antibodies to human Parvovirus B19 in human serum including women of childbearing age where there is a suspicion of exposure to human Parvovirus…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3042-2020·2020-10-07

    Ameditech Recalls ProScreen Drugs of Abuse Tests Due to Performance Failures

    Ameditech is recalling ProScreen Drugs of Abuse Tests because immunoassay enzymes failed performance standards, causing inconsistent detection of compounds.

    Product
    ProScreen" Drugs of Abuse Test (AMT Item/ AMT Description): PSD-6MB/ "ProScreen" Drugs of Abuse Test (MET1000/OPI2000)+AMP+BZO+COC+THC", PSD-6MTDBO-300 /"ProScreen" Drugs of Abuse Test (COC/THC)+BZO+MTD+OPI300+OXY", PSCUP-5M-W/ ProScreen" Drugs of Abuse Cup…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0025-2021·2020-10-07

    Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 1,267 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile. The defect could compromise the sterile field and increase the risk of surgical site infections.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 4/0 Undyed 18" P-12 Cutting, Product Number: SV496G, UDI: 20884521149691 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0043-2021·2020-10-07

    Riverpoint Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 1,244 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile, posing a risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 4/0 Undyed 30" KV-15 TaperCutting CV2279, UDI: 20884521151632 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for use…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0040-2021·2020-10-07

    Riverpoint Recalls Non-Sterile Velosorb Surgical Sutures

    Riverpoint Medical is recalling 1,242 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile, posing a risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 4/0 Undyed 30" P-12 Cutting SV426, UDI: 20884521151731 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for use in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0022-2021·2020-10-07

    Riverpoint Recalls Non-Sterile Velosorb Fast Braided Absorbable Sutures

    Riverpoint Medical is recalling 1,270 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile, posing a risk of surgical site infection.

    Product
    Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 6/0 VL 18" P-10, Product Number: SV32, UDI: 20884521153117 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not for use in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3036-2020·2020-10-07

    Ameditech Recalls ImmuTest Drugs of Abuse Cups for Performance Failures

    Ameditech is recalling ImmuTest Drugs of Abuse Cups because they failed to consistently detect all compounds at labeled levels.

    Product
    ImmuTest Drugs of Abuse Cup (AMT Item Number/ AMT Description): IMCA-5AB-W / "ImmuTest Drugs of Abuse Cup AMP1000+BZO300+COC300+OPI2000+THC50 With Cr, Ni, pH, Bl, S.G.", IMC-8BBCE/ "ImmuTest Drugs of Abuse Cup 8 Drug Detection…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3022-2020·2020-10-07

    Encore Medical Recalls Humeral Socket Inserts Due to Size Mismatch

    Encore Medical is recalling 37 humeral socket inserts because the size etched on the product may differ from the size on the patient sticker label.

    Product
    RSP Standard HUMERAL SOCKET INSERT, 40 MM plus 4MM, HXe-Plus, Part No. 509-00-440
    Category
    Medical Device
    Distribution
    12 states
  • HighFDA (Devices)·Z-3049-2020·2020-10-07

    Ameditech Recalls First Check 4 Panel Drug Cups Due to Performance Failures

    Ameditech Inc is recalling 537,120 units of First Check 4 Panel Drug Cups because they may fail to consistently detect all compounds at labeled levels.

    Product
    First Check 4 Panel Drug Cup: COC/MET1000/OPI2000/THC): (THC/COC); AMT Item Number 990100B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3017-2020·2020-10-07

    Olympus BF-Q180 Bronchovideoscope Recalled for Infection Risk and Regulatory Issues

    Olympus is recalling BF-Q180 bronchovideoscopes because they lack 510(k) clearance and are associated with a higher rate of patient infections.

    Product
    Olympus Medical Systems Corporation (OMSC) Evis Exera II Bronchovideoscope Olympus BF Type Q180 (BF-Q180) All serial numbers - Product Usage: designed to be used with an Olympus video system center, light source, documentation equipment, monitor, EndoTherapy accessories (such as…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3037-2020·2020-10-07

    Ameditech MicroScreen Immunoassay Recalled for Inconsistent Detection Performance

    Ameditech Inc is recalling 23,000 MicroScreen immunoassay units because they failed to consistently detect compounds at labeled levels.

    Product
    MicroScreen (AMT Item Number/ AMT Description): MSCA-6MBAU/ "MicroScreen AMP300/BZO200/COC300/MET300/OPI300/ THC50 with Cr, Ni, pH, Bl, S.G. "
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3024-2020·2020-10-07

    Office Depot Recalls JINYINSHAN KN95 Masks Due to Filtration Failure

    Office Depot is recalling 25,360 JINYINSHAN KN95 masks because test results showed they failed to filter more than 95% of particulates.

    Product
    JINYINSHAN, KN95 PROTECTIVE MASK P1, 20 pieces
    Category
    Medical Device
    Distribution
    Distributed nationwide