The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1101–1125 of 39923

  • SevereFDA (Devices)·Z-1844-2026·2026-04-29

    Medline medical device kits recalled for regulatory compliance rescission

    Medline Industries has recalled six medical device kits (arthrogram trays, angiography packs, and neuro packs) because their 510(k) regulatory clearances have been rescinded by the FDA.

    Product
    Medline Kits: 1) ARTHROGRAM TRAY, Model Number: DYNJ07425; 2) TOL NEURO ANGIO PACK, Model Number: DYNJ38610I 3) ANGIOGRAPHY PACK, Model Number: DYNJ45234A 4) C.I.C.N. ANGIO PACK, Model Number: DYNJ53064B 5) DR. ALLEYNE NEURO PACK, Model Number: DYNJ63779A 6) NEURO CTM IR P
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1927-2026·2026-04-29

    Sequencing Agent SEQ0067 Component Recalled for Potential False-Positive Results

    Foundation Medicine is recalling Sequencing Agent SEQ0067, a component of the FoundationOne CDx test, due to a possible increase in phasing that could result in false-positive BARD1 splice site indel artifact variants.

    Product
    Sequencing Agent SEQ0067, component of FoundationOne CDx (F1CDx)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1928-2026·2026-04-29

    Central Line Dressing Kit containing non-sterile alcohol prep pads recalled

    LSL Healthcare's Central Line Dressing Kit (Model 2717H) is being recalled because it contains Webcol Large Alcohol Prep Pads that were found to be non-sterile. The kits were distributed nationwide in Maryland, Illinois, and Minnesota.

    Product
    LSL Healthcare, Central Line Dressing Kit, Model/Catalog Number: 2717H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1872-2026·2026-04-29

    AccuVu Angiographic Catheter recall due to manufacturing defect

    Angiodynamics is recalling AccuVu Angiographic Catheters due to a manufacturing defect that may prevent a guidewire from passing through the catheter hub. The defect could interfere with proper device function during medical procedures.

    Product
    AccuVu Angiographic Catheter, Omni Flush, Non-Braided, With 2 R/O Markers; ACCU-VU OF 4F X 70CM 035 NB 6SH 2 R/O 2CM; Catalog No.: 13709005; Product/UPN No.: H787137090055 (Box), H787137090050 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1808-2026·2026-04-29

    Handheld UV-C germicidal wand recalls for excessive radiation exposure

    Uvlizer handheld UV-C germicidal wands may expose users and nearby people to ultraviolet radiation at levels above international safety guidelines for skin and eye protection.

    Product
    The product is a handheld ultraviolet-C germicidal wand and contains a combination of five UV-A and UV-C LED lights. The product comes in two configurations: UV-C x 1; UV-A x 4, or UV-C x 2; UV-A x 3. The product has two peak emission wavelengths at 274 nm and 397 nm.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1941-2026·2026-04-29

    Diversatek Viper Wire Guided Balloon Dilator Inflation Tag Incorrect

    Diversatek Healthcare is recalling Viper 3-Stage Wire Guided Balloon Dilators because the attached inflation tag may contain an incorrect part number with wrong balloon diameter sizes and inflation pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 18mm-19mm-20mm, REF 1205-20
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1864-2026·2026-04-29

    Soft-Vu Angiographic Catheter Cobra Non-Braided Manufacturing Defect

    Angiodynamics, Inc. recalls Soft-Vu Angiographic Catheter, Cobra (1), Non-Braided devices due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Cobra (1), Non-Braided; SOFT-VU CB1 4F X 100CM 038 NB 0SH; Catalog No.: 10714017; Product/UPN No.: H787107140175 (Box), H787107140170 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1856-2026·2026-04-29

    Soft-Vu Angiographic Catheter Pigtail Non-Braided Guidewire Passage Defect

    Angiodynamics is recalling Soft-Vu Angiographic Catheter (Pigtail, Non-Braided) due to a manufacturing defect that may prevent a guidewire from passing through the catheter hub's inner diameter.

    Product
    Soft-Vu Angiographic Catheter, Pigtail, Non-Braided; SOFT-VU PT 4F X 100CM 035 NB 10SH; Catalog No.: 10707103; Product/UPN No.: H787107071035 (Box), H787107071030 (Pouch); Box Quantity: 10;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1920-2026·2026-04-29

    IV Administration Sets from Windstone Medical for Infusion Pump Systems

    Windstone Medical Packaging is recalling Custom Convenience Kits Pre Op Kit units due to potential backflow of medication between IV containers and risk of priming failure in gravity and pump administration sets.

    Product
    Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1930-2026·2026-04-29

    Foley Urine Collection Kit recalled for non-sterile alcohol prep pads

    LSL Healthcare is recalling its Foley Urine Collection Kit (Model 1555) because it contains Webcol Large Alcohol Prep Pads that are non-sterile. The kits were distributed nationwide in Maryland, Illinois, and Minnesota.

    Product
    LSL Healthcare, Foley Urine Collection Kit, Model/Catalog Number: 1555
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1854-2026·2026-04-29

    Olympus Thunderbeat II Shears Ultrasonic Mode distal tip detachment risk

    Olympus is recalling Thunderbeat II Shears (5mm, 45cm) because the distal tip component may detach during use, potentially causing patient harm.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 45cm. Model Number: TB2-0545FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1858-2026·2026-04-29

    Soft-Vu Angiographic Catheter, Omni Flush, Non-Braided recalled for manufacturing defect

    Angiodynamics is recalling Soft-Vu Angiographic Catheters due to a manufacturing defect that may prevent guidewires from passing through the catheter hub. The defect affects 1,550 units distributed worldwide.

    Product
    Soft-Vu Angiographic Catheter, Omni Flush, Non-Braided; SOFT-VU OF 4F X 65CM 038 NB 6SH; Catalog No.: 10714001; Product/UPN No.: H787107140015 (Box), H787107140010 (Pouch); Box Quantity: 10 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1851-2026·2026-04-29

    Olympus Thunderbeat II Shears recall due to distal tip detachment

    Olympus Corporation of the Americas is recalling Olympus Thunderbeat II Shears (Model TB2-0520FC) because the distal tip component may detach during use.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 20cm. Model Number: TB2-0520FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1940-2026·2026-04-29

    Diversatek Viper balloon dilator tags may show incorrect inflation parameters

    Diversatek Viper 3-Stage Wire Guided Balloon Dilators are being recalled because the catheter inflation tag may show an incorrect part number with wrong balloon diameters and pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 15mm-16.5mm-18mm, REF 1205-18
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1896-2026·2026-04-29

    Avitene Ultrafoam Microfibrillar Collagen Hemostat Recalled for Foreign Matter

    Davol, Inc. is recalling Avitene Ultrafoam Microfibrillar Collagen Hemostat (Catalog Number 1050030) because the product may contain foreign matter, confirmed to be inspect fragments.

    Product
    Avitene Ultrafoam Microfibrillar Collagen Hemostat - 8cm x 6.25cm x 1cm. Catalog Number: 1050030.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1875-2026·2026-04-29

    AccuVu Angiographic Catheter recalled for guidewire passage defect

    Angiodynamics is recalling the AccuVu Angiographic Catheter (Pigtail, Non-Braided) due to a manufacturing defect that may prevent a properly sized guidewire from passing through the catheter hub's inner diameter.

    Product
    AccuVu Angiographic Catheter, Pigtail, Non-Braided, With 21 R/O Markers; ACCU-VU PT 4F X 70CM 035 NB 10SH 21 R/O 1CM; Catalog No.: 13709804; Product/UPN No.: H787137098045 (Box), H787137098040 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1853-2026·2026-04-29

    Olympus Thunderbeat II shears 35 cm may shed a distal tip component

    Olympus is recalling Thunderbeat II Shears with Ultrasonic Mode, 5 mm and 35 cm, because a distal tip component may detach during use. 3,360 units are affected.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 35cm. Model Number: TB2-0535FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1929-2026·2026-04-29

    LSL Healthcare Central Line Dressing Change Kit Recalled for Non-Sterility

    LSL Healthcare is recalling its Standard Central Line Dressing Change Kit (Model 2717J) because the included Webcol Large Alcohol Prep Pads were found to be non-sterile.

    Product
    LSL Healthcare, Standard Central Line Dressing Change Kit, Model/Catalog Number: 2717J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1866-2026·2026-04-29

    Angiodynamics Soft-Vu Angiographic Catheter Guidewire Blockage Risk

    Angiodynamics is recalling the Soft-Vu Angiographic Catheter, Kumpe, Non-Braided due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 100CM 038 NB 0SH; Catalog No.: 10714021; Product/UPN No.: H787107140215 (Box), H787107140210 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1857-2026·2026-04-29

    Soft-Vu Angiographic Catheter Kumpe Non-Braided manufacturing defect recall

    Angiodynamics is recalling Soft-Vu Angiographic Catheter Kumpe units due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft -Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 40CM 038 NB 0SH; Catalog No.: 10710013; Product/UPN No.: H787107100135 (Box), H787107100130 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1862-2026·2026-04-29

    Soft-Vu Angiographic Catheter, Kumpe, Non-Braided manufacturing defect

    Angiodynamics is recalling Soft-Vu Angiographic Catheter, Kumpe, Non-Braided devices due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 65CM 038 NB 0SH; Catalog No.: 10714014; Product/UPN No.: H787107140145 (Box), H787107140140 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1906-2026·2026-04-29

    Olympus OER-ELITE Endoscope Reprocessor Connecting Tubes Recalled

    Olympus Corporation is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2118) due to potential premature failure of Version 2 reprocessor connecting tube lock levers. The recall affects 1,259 units distributed worldwide.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2118.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1859-2026·2026-04-29

    Soft-Vu pigtail angiographic catheters may block the appropriately sized guidewire

    Soft-Vu Pigtail Angiographic Catheters are being recalled because a manufacturing defect may prevent an appropriately sized guidewire from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Pigtail, Non-Braided; SOFT-VU PT 4F X 65CM 038 NB 10SH; Catalog No.: 10714002; Product/UPN No.: H787107140025 (Box), H787107140020 (Pouch); Box Quantity: 10 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1939-2026·2026-04-29

    Diversatek Healthcare Viper Balloon Dilator catheter inflation tag error

    Diversatek Healthcare is recalling Viper 3-Stage Wire Guided Balloon Dilators because the catheter inflation tag may contain an incorrect part number with wrong balloon diameter sizes and inflation pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 12mm-13.5mm-15mm, REF 1205-15
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1913-2026·2026-04-29

    Arrow Epidural Catheter Kits Recalled Due to Adhesive Manufacturing Defect

    Arrow International is recalling FlexTip Plus Epidural Catheter and FlexBlock Continuous Peripheral Nerve Block Catheter Kits due to incorrect manufacturing of liquid adhesive. The recall affects 190 units distributed nationwide.

    Product
    FLEXTIP PLUS EPIDURAL CATHETER;FLEXBLOCK CONTINOUS PERIPHERAL NERVE BLOCK CATHETER KIT/SET REF ASK-05502-BSM UDI code: (01)10801902209853(17)270831(11)251210(10)33F25K0409 The Arrow Epidural Catheter kit permits access to the epidural space for administration of epidural ane
    Category
    Medical Device
    Distribution
    Distributed nationwide