The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

10751–10775 of 27470

  • SevereFDA (Devices)·Z-0089-2022·2021-10-20

    FDA recalls Eco-Med ultrasound gels due to bacterial contamination risk

    FDA recalls ultrasound gels manufactured by Eco-Med Pharmaceutical due to possible bacterial contamination. Healthcare providers and facilities should stop use immediately.

    Product
    EcoGel 200 - RED Medical Supplies Clear Ultrasound Gel, Model No. 250UG-CMU
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0090-2022·2021-10-20

    FDA Recalls Ultrasound Gel for Possible Bacterial Contamination

    Red Medical Supplies is recalling EcoGel 100 ultrasound gel due to possible bacterial contamination. Approximately 639 units were sold nationwide through Amazon.com.

    Product
    EcoGel 100 - RED Medical Supplies Green Ultrasound Gel, Model No. 250UG-GLU
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0006-2022·2021-10-20

    Abbott Alinity m SARS-CoV-2 Amp Kit Recalled for Potential False Positive Results

    Abbott Molecular has recalled 71,314 units of the Alinity m SARS-CoV-2 Amp Kit due to potential false positive results. The kit was distributed worldwide.

    Product
    Alinity m SARS-CoV-2 Amp Kit (Non-US Assay) and Alinity m SARS-CoV-2 Application Specification File. in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0093-2022·2021-10-20

    Smiths Medical HemoDraw Plus Blood Sampling Sets Recalled for Pressure Monitoring Errors

    Smiths Medical ASD Inc. is recalling 140 HemoDraw Plus Closed Blood Sampling Sets with LogiCal Pressure Monitoring System for pressure shifts and incorrect pressure readings. Affected units were distributed to Austria, France, Germany, Great Britain, and Saudi Arabia.

    Product
    smiths medical medex HemoDraw Plus Closed Blood Sampling Set with LogiCal Pressure Monitoring System, Model Numbers: a) MX961H182P1 b) MX961H212P1 c) MX962H182P1 d) MX962H212P1
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0101-2022·2021-10-20

    Blood sampling system sets recalled for pressure reading and measurement errors

    Smiths Medical is recalling its medex blood sampling system sets due to pressure shifts and incorrect readings that may affect sample collection accuracy.

    Product
    smiths medical medex CBSS-5ML, Triple set, (172/15cm), Model Number DPSHC0092
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0115-2022·2021-10-20

    Elekta Medical Linear Accelerator Diode Failure Risk During Maintenance

    Elekta medical linear accelerators may have a defective diode that could fail destructively when removed, with risk of ejected debris. No injuries have been reported.

    Product
    Elekta Medical Linear Accelerator (EMLA): Elekta Harmony Pro, REF 1555143; Elekta Infinity, REF 1552091, and Elekta Versa HD, REF 1552093.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0099-2022·2021-10-20

    Smiths Medical closed blood sampling system sets recalled for pressure reading errors

    Smiths Medical is recalling CBSS-5ML blood sampling system sets due to reported pressure shifts and incorrect pressure readings that may affect the accuracy of blood sample collection.

    Product
    smiths medical medex CBSS-5ML Zweifach set, Model Number DPSHC0090
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0102-2022·2021-10-20

    Smiths Medical blood sampling system recalled for pressure reading errors

    Smiths Medical has recalled its Medex closed blood sampling system due to pressure shifts and incorrect pressure readings. Approximately 13,620 units were distributed internationally.

    Product
    smiths medical medex CBSS-5ML, Single Set, (172/15cm), Model Number DPSHC0093
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0079-2022·2021-10-20

    Philips Defibrillators Recall: Customers Uninformed of Previous Recalls

    Customers of Philips HeartStart FRx defibrillators were not notified of previous recalls associated with various defibrillator models. This is a Class II medical device recall.

    Product
    Philips, HeartStart FRx + Defibrillator, Model # Model #s: 861304
    Category
    Medical Device
    Distribution
    12 states
  • HighFDA (Devices)·Z-0108-2022·2021-10-20

    Evita V500 Ventilator Software Defect May Cause Temporary Ventilation Loss

    Draeger's Evita V500 ventilator software version 2.51 and lower may restart unexpectedly, briefly stopping ventilation and breathing support. 6,797 units are affected nationwide.

    Product
    Evita V500 Ventilator with Installed CO2 Measurement Option-Intended for the ventilation of adult,pediatric and neonatal patients. Catalog Number: 8416400
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0085-2022·2021-10-20

    Spinal Implant Engraving May Not Match Pouch Labels

    Medtronic Sofamor Danek is recalling the Endoskeleton TAS Interbody System because the engraving on the implants may not match the information on the pouch labels.

    Product
    Endoskeleton" TAS Interbody System with Titan nanoLOCK" Surface Technology, Nanolock 12 Dg Interbody, Large, 12mm
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0104-2022·2021-10-20

    K2M Surgical Removal Tool Recalled for Missing Pins

    K2M, Inc. is recalling 23 units of the Chesapeake Anterior Lumbar Removal Tool because units may arrive with missing pins or in disassembled condition. Pins could dislodge during surgery and enter the surgical cavity, requiring intraoperative removal or revision surgery.

    Product
    Chesapeake Anterior Lumbar (AL) Removal Tool; Cat. no. 2008-90068
    Category
    Medical Device
    Distribution
    9 states
  • HighFDA (Devices)·Z-0082-2022·2021-10-20

    Bio-Rad BioPlex 2200 ANA Screen Control lot incompatible with reagents

    Bio-Rad Laboratories has recalled certain lots of BioPlex 2200 ANA Screen Control Sets due to incompatibility with older lots of ANA Screen Reagent Packs and Calibrator Sets, which may affect test accuracy.

    Product
    BioPlex 2200 ANA Screen Control Set, REF: 663-1131 incompatible with ANA Screen Reagent Packs/ANA Kits, REF: 665-1150; and ANA Screen Calibrator Sets, REF: 663-1101
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0086-2022·2021-10-20

    Endoskeleton TCS Interbody System implant engraving may not match pouch labels

    Medtronic is recalling 9 Endoskeleton TCS Interbody System surgical implants because engraving on the devices may not match the labels on the pouches. The mismatch could result in wrong devices being implanted.

    Product
    Endoskeleton" TCS Interbody System with Titan nanoLOCK" Surface Technology, NanoLock, 6 Deg, Interbody, Medium, 10mm
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0077-2022·2021-10-20

    Gore VIABAHN VBX endoprosthesis recalled for incorrect device dimension labeling

    W L Gore & Associates is recalling GORE VIABAHN VBX balloon expandable endoprosthesis units due to labeling showing incorrect device dimensions. Two units with specification mismatches were distributed to Italy and Lebanon.

    Product
    Heparin, GORE VIABAHN VBX, BALLOON EXPANDABLE ENDOPROTHESIS, REF BXAL085902E, 8 MM X 59 MM 8 Fr, LARGE BALLOON EXPANDLBE, Nominal Stent Diameter 8 mm, Max Post-Dilated Stent Diameter 16 mm, UDI:
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0105-2022·2021-10-20

    Thoraguard Chest Tube Kit 20 Fr Recalled for Adhesive Joint Failure

    Centese Inc. is recalling Thoraguard Chest Tube Kits (20 Fr) because an adhesive joint in the SmartValve component can fail, causing fluid to leak. The affected kits were distributed to a single facility in California.

    Product
    Thoraguard Chest Tube Kit, 20 Fr
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0096-2022·2021-10-20

    Smiths Medical LogiCal Blood Sampling Sets Recalled for Pressure Reading Errors

    Smiths Medical ASD Inc. is recalling 870 units of LogiCal blood sampling sets distributed across Europe and Saudi Arabia due to reported pressure shifts and incorrect pressure readings.

    Product
    smiths medical medex CBSS 5 ml, dreifach proximaler Entnahmeport 60 cm, Model number DPSHC0082
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0087-2022·2021-10-20

    Automation System Interface Module Firmware May Misassociate Test Results to Samples

    Inpeco's automation interface module firmware may incorrectly associate laboratory test results with patient sample IDs, potentially causing incorrect patient results.

    Product
    FlexLab (FLX), Accelerator a3600 (ACP), Aptio Automation (AP2). (Different brand names of same product.)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0084-2022·2021-10-20

    MYLA Diagnostic System Software Versions Recalled for Risk of False Negatives

    BioMerieux MYLA diagnostic system software versions 4.7–4.8.2 may produce false negative results under certain conditions, potentially missing diagnoses. Affected units are being recalled worldwide.

    Product
    MYLA Versions: 4.7, 4.7.1, 4.8, 4.8.1 and 4.8.2, part of the VIRTUO System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0083-2022·2021-10-20

    Cobas EGFR Mutation Test v2 may return false mutation detection results

    The cobas EGFR Mutation Test v2 may produce false positive results for exon 20 insertion mutations, potentially leading to inappropriate treatment. Healthcare providers should verify detected mutations using alternative methods.

    Product
    cobas EGFR Mutation Test v2-Somatic gene mutation detection system Catalog Number :07248563190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0100-2022·2021-10-20

    Smiths Medical Antishunt Sets Recalled Due to Pressure and Reading Errors

    Smiths Medical ASD Inc. is recalling approximately 20,800 Antishunt blood sampling sets due to reported pressure shifts and incorrect pressure readings. The affected model was distributed in Austria, France, Germany, Great Britain, and Saudi Arabia.

    Product
    smiths medical medex CBSS-5ML Antishunt set, (172/15cm), Model Number DPSHC0091
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0106-2022·2021-10-20

    Ion Flexison Biopsy Needle recalled for potential sheath tip separation

    Intuitive Surgical recalled 1,625 Ion Flexison Biopsy Needles due to potential sheath tip separation from the shaft. Affected units are distributed across 29 US states and China; no injuries have been reported.

    Product
    Ion Flexison Biopsy Needle, 19G, Extension Range : 0-3 cm, Ref: 490104-09 and 49004-10, 5-pack, Sterile EO, Rx only, UDI:00886874115978
    Category
    Medical Device
    Distribution
    26 states
  • HighFDA (Devices)·Z-0109-2022·2021-10-20

    Babylog VN500 Ventilator Firmware Defect May Cause Brief Ventilation Interruption

    A software defect in the Babylog VN500 Ventilator may cause it to restart, interrupting ventilation and losing PEEP for about 8 seconds. The issue affects 2,169 units distributed nationwide.

    Product
    Babylog VN500 Ventilator with Installed CO2 Measurement Option-intended for the ventilation of neonatal patients from 0.4 kg (0.88 lbs) up to 10 kg (22 lbs) and pediatric patients from 5 kg (11 lbs) up to 20 kg (44 lbs) bodyweight. Catalog Number: 8417400
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0097-2022·2021-10-20

    Smiths Medical CBSS blood sampling sets recalled for pressure measurement errors

    Smiths Medical is recalling CBSS 5 ml blood sampling sets (Model DPSHC0083) due to reported pressure shifts and incorrect pressure readings. Approximately 7,080 units were distributed in Austria, France, Germany, Great Britain, and Saudi Arabia.

    Product
    smiths medical medex CBSS 5 ml, einfach proximaler Entnahmeport 60 cm, Model Number DPSHC0083
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0110-2022·2021-10-20

    United Orthopedics USTAR II knee implant component recalled for specification failures

    Uoc Usa Inc recalls 3 United Orthopedics USTAR II knee components that fail to meet manufacturing specifications for concentricity and dynamic fatigue testing. These defects could affect implant performance.

    Product
    United Orthopedics USTAR II Knee System USTAR II Knee System Segment Part, RHS, 25 mm Length, Catalog # 2915-1025
    Category
    Medical Device
    Distribution
    Distributed nationwide