The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

10651–10675 of 27470

  • HighFDA (Devices)·Z-0254-2022·2021-11-24

    Out-of-Specification Swabstick Recalled in REGARD Stereotactic Tray

    ROi CPS LLC recalled REGARD Stereotactic Trays due to out-of-specification Povidone-Iodine swabstick components. The recall affects 175 units distributed in Florida, Louisiana, and Missouri.

    Product
    REGARD Stereotactic Tray
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0264-2022·2021-11-24

    Permobil TiLite wheelchairs recalled for improper vehicle restraint

    Permobil TiLite wheelchairs (Models Aero Z and ZRA) used as vehicle passenger seats may not be properly oriented during motor vehicle accidents due to transit tie-down configuration issues. Consumers should discontinue use as passenger seats until replacement tie-downs are installed.

    Product
    Permobil TiLite, Models: Aero Z, and ZRA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0235-2022·2021-11-24

    Syphilis Test Reagent Pack Recalled Due to False Positive Results

    Bio-Rad is recalling 11,610 units of BioPlex 2200 syphilis test reagent packs because they can produce false positive results that don't confirm with follow-up tests, due to elevated reactivity and shelf-life issues.

    Product
    BIO-RAD BioPlex 2200 REF 12000650 SYPH T PACK Syphilis Total & RPR Reagent Pack The BioPlex Syphilis Total & RPR kit is a multiplex flow immunoassay intended for the qualitative detection of total (IgG/IgM) antibodies to Treponema pallidum and the qualitative detection and/or ti
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0236-2022·2021-11-24

    Syphilis Test Calibrator Recalled for False-Positive Reactivity Issues

    Bio-Rad BioPlex 2200 Syphilis calibrator set (791 units, Lot 52953) is recalled due to elevated test reactivity that does not confirm with treponemal tests and potential early shelf-life failure causing measurement bias.

    Product
    BIO-RAD BioPlex 2200 REF 12000651 Syphilis Total & RPR Calibrator Set CAL The BioPlex 2200 Syphilis Total & RPR Calibrator Set is intended for the calibration of the BioPlex 2200 Syphilis Total & RPR Reagent Pack.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0258-2022·2021-11-24

    LEEP PRECISION Integrated System may fail to coagulate during surgery

    CooperSurgical is recalling 75 units of the LEEP PRECISION Integrated System due to a defect where the hand switch may not activate the coagulation function, potentially causing prolonged surgery and bleeding complications.

    Product
    LEEP PRECISION Integrated System, 220V CooperSurgical part numbers: LP-10-220
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0251-2022·2021-11-24

    REGARD Core Biopsy Tray Recalled for Out-of-Specification Component

    ROi CPS LLC recalled 1,200 REGARD Core Biopsy Trays distributed nationwide because a Povidone-Iodine swabstick component supplied by PDI, Inc. was manufactured out of specifications.

    Product
    REGARD Core Biopsy Tray
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0244-2022·2021-11-24

    Bodycad Torque Limiting Adaptor Recalled for Breakage Risk

    Laboratoires Bodycad is recalling its Torque Limiting Adaptor AO Connect due to risk of breakage if used counterclockwise and lack of validation for power tool use. Approximately 10 units were distributed to facilities in Colorado, Michigan, and New York.

    Product
    Torque Limiting Adaptor, AO Connect, 4 N-m, part #027-203, reusable, a component of the Bodycad Fine Osteotomy Implant and Disposable Instrumentation Tray, part #025-004.
    Category
    Medical Device
    Distribution
    3 states
  • SevereFDA (Devices)·Z-0183-2022·2021-11-17

    Ellume COVID-19 Home Test Recalled for Higher Rate of False Positives

    Ellume recalled approximately 427,994 COVID-19 home test kits due to a higher rate of false positive results. The affected kits were distributed in Minnesota, New York, Pennsylvania, Rhode Island, Utah, and Washington.

    Product
    Ellume COVID-19 Home Test
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-0212-2022·2021-11-17

    Photopheresis Kit Recalled Due to Incomplete Testing Before Release

    Therakos is recalling 15 photopheresis kits because they were released before testing was completed. If used, a drive tube leak could cause illness or injury.

    Product
    THERAKOS CELLEX Photopheresis Procedural Kit PRODUCT CODE: CLXUSA
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0213-2022·2021-11-17

    Philips Azurion X-Ray Systems may lock up during simultaneous button presses

    Philips Azurion Interventional X-Ray Systems (software 2.1.x) may experience imaging lock-up when operators simultaneously press both the APC and Float Tabletop buttons.

    Product
    Philips Azurion Interventional Fluoroscopic X-Ray System, Software version 2.1.x, Model numbers 722063, 722064, 722067, 722068, 722078, 722079, 722221, 722222, 722223, 722224, 722225, 722226, 722227, 722228. (Azurion 3 M12, Azurion 3 M15, Azurion 5 M12, Azurion 5 M20, Azurion 7
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0207-2022·2021-11-17

    McKesson PREVENT HT Winged Blood Collection Needles Recall for Safety Mechanism Difficulty

    McKesson PREVENT HT Safety Winged Blood Collection Needles may have difficulty activating their safety mechanism. The recall affects units distributed nationwide.

    Product
    McKesson PREVENT HT Safety Winged Blood Collection Needle with Tube Holder, MFR # 16-NBCH21GS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0206-2022·2021-11-17

    McKesson PREVENT HT Blood Collection Needle Safety Mechanism Activation Issue

    McKesson PREVENT HT blood collection needles with specific lot numbers may have difficulty activating their safety mechanism. Healthcare facilities should contact the manufacturer for replacement guidance.

    Product
    McKesson PREVENT HT Safety Winged Blood Collection Needle with Tube Holder, MFR # 16-NBCH22GS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0215-2022·2021-11-17

    Hemodialysis Delivery System Software May Use Incorrect Treatment Parameters

    Baxter's Hemodialysis Delivery System may incorrectly revert to old prescription values when operators change prescriptions after filter changes, potentially resulting in incorrect treatment parameters.

    Product
    Hemodialysis Delivery System, Software Version 2.x.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0210-2022·2021-11-17

    Covidien Emprint Ablation Catheter temperature monitoring defect

    Covidien is recalling the Emprint Ablation Catheter due to a defect in temperature monitoring circuitry. If the cooling system fails during use, the device tip could overheat, causing tissue burns, unintended ablation, and allergic reactions.

    Product
    Covidien Emprint Ablation Catheter with Thermosphere Technology Bronchoscopic Ablation, CFN CA108L1
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0209-2022·2021-11-17

    Safety Blood Collection Needles Recalled Due to Safety Mechanism Activation Difficulty

    Henry Schein safety blood collection needles may have difficulty activating their safety mechanism, potentially increasing needlestick injury risk. Affected lots were distributed nationwide with expiration dates through late 2025.

    Product
    HENRY SCHEIN Safety Blood Collection Needle 22Gx 1 1/4 Inch, REF 570-2068, 100pcs/box 1000pcs/ctn 350*210*350mm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0208-2022·2021-11-17

    Safety Blood Collection Needle Recalled for Safety Mechanism Activation Issues

    Zhejiang Kindly Medical Devices is recalling Henry Schein Safety Blood Collection Needles due to potential difficulty activating the safety mechanism. Affected lot numbers distributed nationwide.

    Product
    HENRY SCHEIN Safety Blood Collection Needle 21Gx 1 1/4 Inch, REF 570-2067, 100pcs/box 1000pcs/ctn 350*210*350mm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0211-2022·2021-11-17

    QuikClot Combat Gauze Recalled for Potential Sterile Packaging Seal Failure

    Z-Medica is recalling 2400 units of QuikClot Combat Gauze due to potential packaging seal failures that could compromise sterile barrier integrity. Affected lot 12645 was distributed nationwide.

    Product
    QuikClot Combat Gauze-For Temporary External Use To Control Traumatic Bleeding Model / Part# 200
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0205-2022·2021-11-17

    McKesson Safety Blood Collection Needles Recalled Over Safety Mechanism Activation Risk

    Nationwide recall of McKesson PREVENT HT Safety Blood Collection Needles (22G 1 1/4 inch) due to potential difficulty activating the safety mechanism. The protective feature may fail to engage properly during use.

    Product
    McKesson PREVENT HT Safety Blood Collection Needles, 22G 1 1/4 inch, MFR # 16-NBC22GS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0204-2022·2021-11-17

    McKesson Safety Blood Collection Needles Recalled for Safety Mechanism Defect

    McKesson PREVENT HT Safety Blood Collection Needles are being recalled due to potential difficulty in activating the safety mechanism. The recall affects needles distributed nationwide, including specific lot numbers with expiration dates through May 2025.

    Product
    McKesson PREVENT HT Safety Blood Collection Needles, 21G 1 1/4 inch, MFR # 16-NBC21GS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0119-2022·2021-11-10

    Monoject Prefilled Syringe Plunger Defect Recall: Air Reintroduction Risk

    Monoject prefilled syringes in medical kits may have a plunger that rebounds after air expulsion, potentially reintroducing air into the syringe. This FDA Class I recall affects approximately 9,378 units distributed in Florida and Pennsylvania.

    Product
    Monoject 0.9% Sodium Chloride, Flush Prefilled Syringe, 10 mL, REF: 8881570121 inside the following Aligned Medical Solutions Custom Convenience Kits: AMS-9041CP Leaderflex Insertion Kit with Ultrasound, AMS-9046CP-1 Insertion Tray-RX, AMS8939A Universal Procedure Pack w/Sp
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-0194-2022·2021-11-10

    IPL Coupling Gel and EcoGel 200 Recalled for Bacterial Contamination

    Lumenis, Inc. is recalling IPL Coupling Gel and EcoGel 200 due to potential bacterial contamination. Approximately 11,064 units were distributed worldwide.

    Product
    IPL Coupling Gel, I L (AX1009013), 12 pack of 0.25 L (AX1009018), 6 pack of 1 L (AX1009019 or AX1009063); and IPL Coupling Gel or EcoGel 200, 0.25 L (AX1009012) manufactured by Eco-Med Pharmaceutical
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0186-2022·2021-11-10

    Flexor Check-Flo Introducer Sets recalled due to misplaced radiopaque marker band

    Cook Inc. recalls Flexor Check-Flo Introducer Sets where the radiopaque marker band is incorrectly positioned, which may not be discovered until the device is used in a patient under fluoroscopy, increasing procedural time.

    Product
    Flexor Check-Flo Introducer - Raabe Modification, Introducer Set, RPN KCFW-5.0-38-90-RB-RAABE, GPN G13069 The introducer sheath incorporates a hydrophilic coated Flexor shaft with a hemostasis valve and is provided with a dilator.
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-0184-2022·2021-11-10

    Flexible Intubation Videoscope Recall Due to Sterility Assurance Failure

    Karl Storz FIVE S 3.5x65 flexible intubation videoscopes failed sterility assurance testing. The recall affects 532 units distributed across the US and Canada due to infection risk.

    Product
    FIVE S 3.5x65, Flexible Intubation Videoscope, REF: 091361-01 (1 Unit), and 091361-06 (6 Units)
    Category
    Medical Device
    Distribution
    40 states
  • HighFDA (Devices)·Z-0193-2022·2021-11-10

    Siemens Aptio Interface Module may misassociate laboratory test results

    Siemens Healthcare's Aptio Automation Interface Module firmware may incorrectly associate test results with the wrong sample IDs, potentially affecting clinical decision-making.

    Product
    Aptio Automation Interface Module to ADVIA Centaur XP/XPT. Aptio by Siemens Centaur Interface Firmware (FW) CENa_3-1-0-1 and lower. SMN 10703038
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0190-2022·2021-11-10

    Arietta 850 Ultrasound Software Displays Cardiology Measurements Incorrectly

    FujiFilm Arietta 850 ultrasound systems with affected software versions display cardiology measurement results incorrectly. The recall affects 38 units distributed nationwide.

    Product
    Arietta 850 Ultrasound- Software Version: V1.0.0 through V4.1.3
    Category
    Medical Device
    Distribution
    Distributed nationwide