The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

10601–10625 of 27470

  • HighFDA (Devices)·Z-0285-2022·2021-12-01

    Siemens CT Scanner Software May Cause Diagnostic Workflow Delays

    Siemens SOMATOM Definition Edge CT scanners with syngo.CT VB20 software may experience workflow interruptions, causing diagnostic delays, need for repeat scans, and additional contrast media use. 298 units nationwide are affected.

    Product
    SOMATOM Definition Edge with software syngo.CT VB20 Model #10590000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0277-2022·2021-12-01

    CT imaging system ceiling mount bracket shaft wear may cause equipment to fall

    A CT fluoroscopy imaging system ceiling mount's bracket shaft may wear excessively and go undetected, potentially causing the bracket to detach and fall, risking injury to patients, operators, or service personnel.

    Product
    Continuous CT Fluoroscopy DVI Ceiling Mount - CCT Arm DVI Option - CT Vision ACQSIM CT System Number: 728209 Continuous CT (CCT) is a CT or PET/CT product option that enables physicians and radiologists to produce real-time CT images to facilitate image-guided surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0269-2022·2021-12-01

    FDA Recalls Western Oxytote DTE Digital VIPR System Due to Battery Rupture Risk

    Western/Scott Fetzer Company is recalling 40 units of the Oxytote DTE Digital VIPR System due to battery rupture risk. The device may emit fumes and smoke when the battery ruptures and plastic shroud breaks apart.

    Product
    Western Oxytote DTE Digital VIPR System (with D-size cylinder) Model: MNDS-602
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-0289-2022·2021-12-01

    CT Scanner Software May Cause Workflow Delays and Patient Rescans

    Siemens SOMATOM Edge Plus CT scanners with syngo.CT VB20 software may experience workflow interruptions, potentially delaying diagnoses and requiring patient rescans. The issue affects 64 units nationwide.

    Product
    SOMATOM Edge Plus with software syngo.CT VB20 Model #10267000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0282-2022·2021-12-01

    Medtronic Cardiac Device Software Affected by Data Processing Error

    Medtronic is recalling software used in certain cardiac implant devices due to a data processing error that may fail to collect episode data. Approximately 18,715 devices are affected worldwide.

    Product
    Medtronic CareLink SmartSync Device Manager application software (D00U005) used by the following Medtronic Cobalt and Crome implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds): Cobalt XT VR: DVPA2D1, DVPA2D4; Cobalt VR:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0239-2022·2021-12-01

    Medical imaging device missing required radiation safety labels

    Philips Healthcare is recalling DigitalDiagnost C90 medical imaging devices because some units lack required radiation warning labels and X-ray certification statements. Affected customers should contact Philips to have the missing labels applied.

    Product
    DigitalDiagnost C90
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0242-2022·2021-12-01

    GE Healthcare CT Systems Display Incorrect Radiation Doses During Certain Exams

    GE Healthcare's Revolution CT systems may display accumulated radiation doses up to 100 times higher than the actual dose delivered during certain interventional imaging procedures. The displayed value is incorrect, but the actual dose patients receive is accurate.

    Product
    Computed Tomography Systems Revolution CT, Revolution CT ES, Revolution Apex, Revolution CT with Apex edition
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0295-2022·2021-12-01

    Medtronic Wireless Recharger Model WR9200 Becomes Unresponsive on Improper Use

    Medtronic is recalling the Wireless Recharger Model WR9200 used with RestoreUltra and RestoreSensor neurostimulator implants. The recharger becomes unresponsive if charging instructions from the user guide are not followed correctly.

    Product
    Medtronic Wireless Recharger Model WR9200 included in the RS7200 Recharger Kit used by the RestoreUltra (Model 37712), RestoreSensor (Model 37714), Restore Ultra SureScan MRI (Model 97712), and RestoreSensor SureScan MRI (Model 97714) implantable neurostimulators.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0288-2022·2021-12-01

    Siemens SOMATOM Confidence CT Scanners Recalled for Software-Related Workflow Interruptions

    Siemens SOMATOM Confidence CT scanners may experience software-related workflow interruptions that could delay patient diagnosis. The recall affects 104 units nationwide; affected facilities should contact the manufacturer for remediation instructions.

    Product
    SOMATOM Confidence with software syngo.CT VB20 Model #10590100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0241-2022·2021-12-01

    Philips CombiDiagnost R90 X-ray systems missing required radiation warning labels

    Philips Healthcare is recalling CombiDiagnost R90 X-ray systems because some units lack required FDA radiation warning labels and X-ray certification statements. No injuries have been reported.

    Product
    CombiDiagnost R90 is multi-functional general R/F systems.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0293-2022·2021-12-01

    Medtronic Wireless Recharger for InterStim Micro May Become Unresponsive

    Medtronic's wireless recharger for the InterStim Micro implantable neurostimulator may become unresponsive if charging procedures from the user guide are not followed. Approximately 10,081 devices are affected nationwide.

    Product
    Medtronic Wireless Recharger Model WR9220 included in the RS5200 Recharger Kit used by the InterStim Micro (Model 97810) implantable neurostimulator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0279-2022·2021-12-01

    PET/CT Imaging System Ceiling Mount May Detach Due to Bracket Wear

    Philips TruFlight Select PET/CT imaging systems have a Monitor Bracket Assembly that may detach from the ceiling mount due to undetected shaft wear, posing a risk of injury to patients, staff, and bystanders.

    Product
    Continuous CT Fluoroscopy DVI Ceiling Mount - CCT Arm DVI Option - TruFlight Select PET/CT System Number: 882438 Continuous CT (CCT) is a CT or PET/CT product option that enables physicians and radiologists to produce real-time CT images to facilitate image-guided surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0306-2022·2021-12-01

    BD Nexiva IV Catheters Recalled Due to Non-Sterile Packaging Breach

    Becton Dickinson is recalling BD Nexiva IV catheter systems because of a packaging breach that renders them non-sterile. The recall affects 155,840 devices distributed nationwide.

    Product
    BD Nexiva, 20 GA 1.00 IN (1.1 X 25 mm), 3660 ml/hr. 61ml/min; Closed IV Catheter System- Dual port -61 mL/min (3660 mL/hr)-0.5mL, REF 383536; BD Q-Style Luer Access Split Septum BD Vialon Material; BD Instaflash Needle Technology; Rx Only, Sterile EO. BD Nexiva closed IV cat
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0272-2022·2021-12-01

    Clinical Chemistry Analyzer Software Defects May Produce Inaccurate Results

    Abbott ARCHITECT clinical chemistry analyzers with software 9.41 and earlier contain defects affecting calibration, sample handling, and quality control that may produce inaccurate diagnostic results.

    Product
    ARCHITECT c4000 REF 02P24-01/2P24, 1P86, 1R24, and 1R25; ARCHITECT c8000 REF 01G06-11/1G06; ARCHITECT c16000 REF 03L77-01/3L77;
    Category
    Medical Device
    Distribution
    50 states
  • HighFDA (Devices)·Z-0287-2022·2021-12-01

    CT Scanner Software May Cause Workflow Interruptions and Diagnosis Delays

    Siemens SOMATOM Drive CT scanners with syngo.CT VB20 software may experience workflow interruptions that delay diagnosis and require additional patient scans. Approximately 75 units are affected nationwide.

    Product
    SOMATOM Drive with software syngo.CT VB20 Model #10431700
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0290-2022·2021-12-01

    Endurant Stent Graft System spindle detachment during deployment

    Medtronic recalls 2 Endurant Stent Graft System devices due to potential spindle detachment from the hypotube during surgical deployment. The mechanical failure could affect graft positioning.

    Product
    Endurant Stent Graft System REF/Description: ENTF2525C70EE STENT GRAFT ENTF2525C70EE ENDURANT TUBE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0234-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device: Inner Lumen Detachment Risk

    Arrow International is recalling 1918 units of the Arrow-Trerotola Percutaneous Thrombolytic Device due to inner lumen detachment that can cause embolization, requiring emergency retrieval and delaying treatment.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-65709-WC The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venous
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0224-2022·2021-11-24

    FDA Recalls Scrip Ultrasound Gel for Potential Bacterial Contamination

    Scrip Inc is recalling Scrip Ultrasound Gel Clear (5L) nationwide due to potential bacterial contamination. Affected units may cause harm if contaminated product contacts patients during ultrasound procedures.

    Product
    Scrip Ultrasound Gel Clear, 5L Intended for use in acoustic coupling of ultrasound transducer to tissue
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0225-2022·2021-11-24

    Scrip Creme ultrasound lotion recalled for bacterial contamination

    Scrip Creme All Purpose Lotion is being recalled due to bacterial contamination in this ultrasound coupling lotion. The product—1001 gallons in lots distributed between August 2018 and August 2021—was distributed nationwide.

    Product
    Scrip Creme All Purpose Lotion Intended for use in acoustic coupling of ultrasound transducer to tissue
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0231-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device Inner Lumen Detachment Recall

    The inner lumen of Arrow-Trerotola Over-The-Wire PTD catheters (7FR) can detach from the device, causing an embolism. This requires additional medical intervention and delays treatment.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-12709-WC The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venous
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0233-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device inner lumen detachment and embolization risk

    Arrow-Trerotola PTD catheters are being recalled because the inner lumen can detach from the device basket, causing embolization that requires additional intervention. 1,167 units are affected.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-65709-W The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venousf
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0232-2022·2021-11-24

    Arrow-Trerotola Percutaneous Thrombolytic Device Catheter Lumen Detachment Recall

    Arrow International is recalling Arrow-Trerotola Percutaneous Thrombolytic Device catheters because the inner lumen can detach from the device basket, causing embolization requiring additional intervention and delaying dialysis therapy. Approximately 1,245 units are affected worldwide.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit Percutaneous Thrombolytic Device : 7FR Product Code: PT-65709-HFWC The Arrow-Trerotola" Percutaneous Thrombolytic Device (PTDTM) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-veno
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0253-2022·2021-11-24

    REGARD Newborn Tray Recalled Due to Out-of-Spec Antiseptic Component

    ROi CPS LLC is recalling REGARD Newborn Trays (lot 86453F) distributed in FL, LA, and MO because some units contain a povidone-iodine swabstick component manufactured out of specifications.

    Product
    REGARD Newborn Tray
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0259-2022·2021-11-24

    LEEP PRECISION Generator 120V Hand Switch Coagulation Function Failure

    CooperSurgical is recalling 244 LEEP PRECISION Generator 120V units because the hand switch's coagulation function may fail to operate properly, potentially requiring medical intervention to control bleeding during surgical procedures.

    Product
    LEEP PRECISION Generator 120V Cooper Surgical Part Number: LP-20-120
    Category
    Medical Device
    Distribution
    Distributed nationwide