The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

10076–10100 of 27470

  • HighFDA (Devices)·Z-0942-2022·2022-04-20

    ARIA Radiation Therapy Management Software May Cause Treatment Location Error

    Varian ARIA radiation therapy management software versions 13.6 through 16.1 may generate incorrect treatment plan values that could direct radiation therapy to the wrong location. No illnesses have been reported.

    Product
    ARIA Radiation Therapy Management (RTM) VERSIONS 13.6, 15.1, 15.5, 15.6, 16.0, 16.1
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0921-2022·2022-04-20

    Abbott Vascular 20/30 Indeflator Recalled for Leaks and Connection Failures

    Abbott Vascular recalls 20/30 Indeflator medical devices due to increased complaints of leaks and loose connections. The recall affects 17 product lots distributed nationwide and internationally.

    Product
    20/30 INDEFLATOR -REF 1000184 WPL2122268-01 (2019-03-01)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0935-2022·2022-04-20

    ECG Electrode Set Fails Electrical Safety, May Prevent Effective Defibrillation

    Graphic Controls' CLARAVUE pediatric electrode set fails electrical safety standards. The device may not deliver adequate charge during defibrillation, potentially rendering emergency treatment ineffective.

    Product
    CLARAVUE Pre-wired Electrode IP-SET N3 - PEDIATRIC-US Model: 32028776 50401-US
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0902-2022·2022-04-20

    Cardinal Health Surgical Gloves Recalled for Lack of Sterilization

    Cardinal Health PROTEXIS PI and PI Classic surgical gloves were distributed without proper sterilization. The affected 486,578 pairs should not be used, as non-sterile gloves present an infection risk during surgical procedures.

    Product
    Cardinal Health PROTEXIS PI and PI Classic, Surgical Gloves
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0914-2022·2022-04-20

    Orthopedic surgical driver oversized, affecting hammertoe correction

    Nextremity Solutions is recalling the Nextra Hammertoe Correction System Driver (SKU: NX-DR) due to oversizing at the proximal end, which impairs connection and removal from the implant, causing surgical delays. The defect affects 239 units distributed in the US, Japan, and the Netherlands.

    Product
    Nextra Hammertoe Correction System Driver SKU: NX-DR Orthopedic surgical instrument
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0916-2022·2022-04-20

    ROTAWIRE guidewires recalled due to potentially compromised sterile pouch seals

    Boston Scientific is recalling ROTAWIRE Drive guidewires due to potentially open pouch seals that could compromise product sterility. Affected units were distributed in the US, territories, Japan, and Canada.

    Product
    ROTAWIRE Drive and wireClip Torquer, ROTAWIRE Drive Extra Support
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0904-2022·2022-04-20

    AccessPLUS hemostasis valves recalled for internal guidewire entrapment risk

    Merit Medical is recalling AccessPLUS Large Bore Hemostasis Valves due to an internal design gap that can trap guidewires, potentially delaying medical procedures.

    Product
    AccessPLUS Large Bore Hemostasis Valves, Catalog Code: 580758001, 580774001, IN8152/C, K04-01197, K05T-01863, K09-09102B, K09-10388A, K09-12917, K09-13501AP, K10-05457AP, K10-05635, K10-05868P, K10-05872P, K12-08303, K12-10346, K12-10375, K12-10724AP, K12-10962, K12-11413, MAP150
    Category
    Medical Device
    Distribution
    49 states
  • HighFDA (Devices)·Z-0906-2022·2022-04-20

    Integra Universal Flexible Arm Recall: Internal Cable May Break

    Integra LifeSciences is recalling the Universal Flexible Arm (part number REF 1362275) because excess tightening force can break the internal cable at the tip, rendering the device unusable.

    Product
    Integra Universal Flexible Arm part number REF 1362275
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0931-2022·2022-04-20

    Siemens Atellica CH Lithium reagent recalled for potential reagent carryover

    Siemens Healthcare Diagnostics recalls approximately 2,158 units of Atellica CH Lithium_2 reagent (Lot Numbers 110108, 110185, 110238, 110302) due to potential for reagent carryover affecting quality control results, patient samples, and calibrator results.

    Product
    Atellica CH Lithium_2 (LITH_2), Siemens Material Number 11097637
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0941-2022·2022-04-20

    Medline Laryngeal Masks recalled due to potential cuff disconnection

    Medline Industries is recalling approximately 8,990 cases of Standard PVC Laryngeal Masks distributed nationwide because the mask cuff may disconnect from the breathing tube.

    Product
    Medline Standard PVC Laryngeal Masks, 1 device per pouch, 5 each pouches per box
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0925-2022·2022-04-20

    Abbott Vascular Plus 30 Priority Pack Recalled for Connection Leaks

    Abbott Vascular is recalling seven lots of the Plus 30 Priority Pack due to increased reports of leaks and intermittent loose connections in the vascular devices.

    Product
    Plus 30 Priority Pack w/.096 RHV - REF 1000183 WPL2122277-01 (20-03-01) Plus 30 Priority Pack w/.115 RHV - REF 1000185-115 WPL2122279-01 (2019-03-01)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0939-2022·2022-04-20

    Cardiac electrode fails electrical safety test; defibrillation may not work

    The CLARAVUE Pre-wired Electrode does not meet electrical safety standards for defibrillators. It may not deliver effective electrical charge during emergency defibrillation.

    Product
    CLARAVUE Pre-wired Electrode - IP SET 6V RT ADULT-US Model: 32028780 50603-US
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0872-2022·2022-04-20

    Conductivity Sensors in Dialog Hemodialysis Systems May Crack and Leak

    B Braun Medical Inc is recalling conductivity sensors used in Dialog and Dialog+ hemodialysis systems due to potential cracks that could cause dialysate circuit leaks, affecting ultrafiltration during treatment.

    Product
    Conductivity Sensors utilized on Dialog and Dialog+ Hemodialysis Systems. Conductivity Sensor (BIC) - VERSION 2, Article Code Number 3456102A. These conductivity sensors may be used as spare parts for the following dialysis machines: 710200L (UDI 04046963686345), 710200S (UDI 0
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0899-2022·2022-04-20

    iTotal Identity Knee Replacement System—incorrect tibial base plate packaged

    Conformis is recalling specific units of the iTotal Identity Posterior Stabilised Knee Replacement System due to incorrect tibial base plate implants being packaged in surgical kits.

    Product
    iTotal Identity Posterior Stabilised (PS) Knee Replacement System Model Number: TPS-301-1113-020101
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0903-2022·2022-04-20

    Access-9 Hemostasis Valves Recalled for Guidewire Entrapment Risk

    Merit Medical Systems is recalling 36,445 Access-9 Large Bore Hemostasis Valves due to an internal gap that can trap the guidewire, potentially delaying medical procedures.

    Product
    Access-9 Large Bore Hemostasis Valves, Catalog Code: 580775001, IN8112/C, K05-00053H, K05-00109G, K05-00137K, K05-00410G, K05-00438G, K05-00502F, K05-00587D, K05-01052, K05-01706C, K05-01880K, K05-02130, K05-02595, K09-12599A, K10-05487P, K12-00264, MAP111/F, MAP112/B, MAP112/F,
    Category
    Medical Device
    Distribution
    49 states
  • HighFDA (Devices)·Z-0936-2022·2022-04-20

    Recalled CLARAVUE Pre-wired Electrode Set May Fail During Defibrillation

    Graphic Controls is recalling CLARAVUE Pre-wired Electrode sets because they fail to meet electrical safety specifications for defibrillators, potentially delivering inadequate charge during emergency treatment.

    Product
    CLARAVUE Pre-wired Electrode - IP SET M3 RT ADULT-US Model: 32028777 50600 US
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0943-2022·2022-04-20

    Ventilator trolley mounting brackets can detach and cause device to fall

    The mounting brackets on Breas Ventilator Trolleys can become detached, allowing ventilators to fall. This poses an injury risk to people near the equipment.

    Product
    Breas Ventilator Trolley with the Vivo 50/60/65 and Vivo 45LS ventilator models Article no 007384
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0920-2022·2022-04-20

    Verigene Processor SP Recalled for No Call Results

    Luminex Corporation is recalling 4 Verigene Processor SP diagnostic devices that repeatedly failed to produce results, returning No Call outputs instead. Two of three customer complaints involved this malfunction.

    Product
    Verigene Processor SP, Model Numbers: 10-0000-07 and 10-0000-07-R
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0919-2022·2022-04-20

    MUSE Cardiology System edits and diagnosis data lost after test signed

    GE Healthcare's MUSE Cardiology Information System may lose test measurement edits and diagnosis statements after signing. The Class II recall affects 147 units in the US and internationally.

    Product
    MUSE Cardiology Information System, Model Numbers: a) 3101011-040, b) 3101010-401, c) 3101010-009, d) 3101010-008
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0913-2022·2022-04-20

    Hammertoe Correction Surgical System Recalled for Driver Connection Defect

    Nextremity Solutions recalls the Nextra Hammertoe Correction System because the driver's proximal end is oversized, making it difficult to connect and remove from the implant, potentially delaying surgery.

    Product
    Nextra Hammertoe Correction System 3.5 Middle and 3.2 Proximal Saw Cut SKU: NX-3532K-SC Orthopedic surgical instrument
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0924-2022·2022-04-20

    Abbott INDEFLATOR Plus 30 Device Recalled for Leaks and Connection Faults

    Abbott Vascular is recalling INDEFLATOR Plus 30 balloon inflators due to increasing complaints of leaks and intermittent loose connections that could affect device function during medical procedures.

    Product
    INDEFLATOR Plus 30 - REF 1000183 WPL2122277-01 (2019-03-01)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0861-2022·2022-04-13

    Defibrillator devices unapproved for US market recalled by FDA

    Remote Diagnostic Technologies recalls Tempus LS defibrillators not approved for US distribution. Two units were distributed in Illinois and Kansas.

    Product
    Tempus LS, Type DGE1, CAT 00-3010, REF 3.940590, Software version 1.3.5, UDI: (01)07613365001693
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0815-2022·2022-04-13

    CT Scanner Dose Display Error in GE Healthcare Revolution Systems

    GE Healthcare Revolution Apex and Revolution CT systems display accumulated radiation doses inaccurately high in certain situations. No injuries have been reported.

    Product
    Revolution Apex, Revolution CT with Apex Edition
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0884-2022·2022-04-13

    Alinity m HBV AMP Kit Recalled for Risk of Falsely High Test Results

    Abbott Molecular is recalling the Alinity m HBV AMP Kit due to potential for falsely high results on negative samples. The kits are used for Hepatitis B virus testing in the US and internationally.

    Product
    Alinity m HBV AMP Kit (US and CE)
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0867-2022·2022-04-13

    X-ray fluoroscopy system may deliver excessive radiation dose

    Shimadzu FLUOROspeed X1 fluoroscopy systems may deliver radiation doses exceeding federal regulatory limits in specific fluoroscopic operating modes due to inadequate installation adjustment criteria.

    Product
    MODEL: X-RAY R/F SYSTEM FLUOROspeed X1
    Category
    Medical Device
    Distribution
    37 states