The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

9226–9250 of 40095

  • ModerateFDA (Devices)·Z-2579-2023·2023-09-20

    Copaliner Cavity Varnish Recalled for Solvent Mislabeling Error

    Keystone Industries recalls Copaliner Cavity Varnish after discovering bottles of Copaliner Solvent were accidentally packaged in boxes labeled as varnish. The error affected 337 units distributed worldwide.

    Product
    Keystone Bosworth Copaliner Cavity Varnish .5oz (14 ml)- Intended to provide a marginal seal between the dentin and amalgam which helps to protect against penetration of amalgam into the dentina Item No. 0921526
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2576-2023·2023-09-20

    Microbiologics KWIK-STIK ANA quality control set missing strain

    Microbiologics Inc is recalling one lot of KWIK-STIK ANA QC sets missing one of three bacterial strains required for microbiological testing.

    Product
    KWIK-STIK, ANA (3 Strains) QC Set, REF 5065P; Microbiological testing
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2535-2023·2023-09-20

    Procedural Kits with Ultrasonic Gel Recalled for Inappropriate Use Labeling

    Advance Medical Designs is recalling 117,875 procedural kits containing ultrasonic transmission gel due to mislabeling of use instructions. The recall affects kits distributed to the United States, Canada, United Kingdom, Panama, and Netherlands.

    Product
    Procedural kits containing ultrasonic transmission gel, Item Numbers: a) 20-PC424, b) 20-PC448, c) 20-PC548, d) 20-PC596, e) 20-PC648
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2533-2023·2023-09-20

    Ultrasound gel recalled for mislabeling with inappropriate use instructions

    Advance Medical Designs is recalling 50-GEL20 ultrasound gel (13,750 units, lot 21043C2328) due to mislabeling with inappropriate use instructions. The product was distributed in the US, Canada, UK, Panama, and the Netherlands.

    Product
    50-GEL20; Ultrasound gel
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2536-2023·2023-09-20

    Ultrasound Gel Procedural Kits Recalled for Inappropriate Use Mislabeling

    Advance Medical Designs is recalling procedural kits containing ultrasonic transmission gel because the product labeling does not accurately indicate appropriate use. The recall affects 460 units distributed to the US, Canada, UK, Panama, and Netherlands.

    Product
    Procedural kits containing ultrasonic transmission gel, Item Numbers: a) 28-EG103, b) 28-EG125, c) 28-EG135, d) 28-EG151, e) 28-EG161, f) 28-EG163, g) 28-EG197
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2543-2023·2023-09-20

    Landauer nanoDot radiation dosimeters recalled for potential accuracy deviation

    Landauer is recalling nanoDot D2DNS radiation monitoring dosimeters due to a potential defect in the OSL material. Affected devices may provide radiation exposure readings outside the specified +/-5.5% accuracy range.

    Product
    nanoDot D2DNS, Model Numbers: a) 03056-000 (EMEA number VINLNAN002); b) 03056-1MO; c) 03056-3MO; d) 03056-KIT; radiation monitoring dosimeter used with the microSTAR readers
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2580-2023·2023-09-20

    Denture relining kit recalled for outer box labeling error

    Keystone Industries is recalling 240 units of Henry Schein Hard Line Chairside Reline kits because the outer box is labeled as Soft Line, though the contents and instructions are correctly labeled.

    Product
    Henry Schein Hard Line Chairside Reline kit-Resilient Acrylic Denture Relining Material KI Item No.: 0921940HS Henry Schein Item No.: 570-0718
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2518-2023·2023-09-13

    Trocar with oversized shaft obscures surgical view in brain operations

    Aesculap trocars manufactured with shafts too long obstruct the visual field when used with neuroendoscopes in brain surgery. Affected units distributed in nine states should not be used.

    Product
    For intraventricular indications mainly used for operations within the brain ventricles. Product Code: FF399R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2515-2023·2023-09-13

    ISee Ortho-K Contact Lenses Recalled Due to Lack of FDA Approval

    Paragon Vision Sciences is recalling 83,542 ISee Ortho-K lenses because the manufactured product lacks FDA approval coverage. This is a Class II recall.

    Product
    ISee Ortho-K Lens
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2523-2023·2023-09-13

    Reusable Endoscopy Distal Attachments Recalled for Excessive DEHP Levels

    Aomori Olympus recalls 1,252 reusable distal attachment devices with DEHP chemical levels exceeding safe exposure limits per medical device standards. Devices distributed nationwide in the United States.

    Product
    Reusable distal attachments Models: MH-462, MH-463, MH-464, MH-465, MH-466, MH-483, MH-587, MH-588(US), MH-589, MH-590, MH-591, MH-592, MH-593, MH-594, MH-595, MH-596, MH-597, MH-598, MAJ-289, MAJ-290, MAJ-291, MAJ-292, MAJ-293, MAJ-294, MAJ-295, MAJ-296, MAJ-297, MAJ-663, MAJ-
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2513-2023·2023-09-13

    Cook Lead Clipper Cardiac Device Sterility Recall Due to Packaging Defect

    Cook Vandergrift is recalling approximately 15,951 Cook Lead Clipper devices due to potential sterility compromise from packaging seal breaches. The surgical tool is used for cardiac lead retrieval procedures.

    Product
    Cook Lead Clipper- An auxiliary tool indicated for use in patients requiring percutaneous retrieval of cardiac leads. Order Number (GPN): G20003 Reference Part Number (RPN): LR-CLP001
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2519-2023·2023-09-13

    Hip Prosthesis Implants Recalled for Size Mismatch Between Label and Device

    Zimmer, Inc. is recalling M/L Taper Hip Prosthesis implants where the outer package labeling and product etch do not match the actual implant size. This mislabeling could lead to implantation of the wrong-sized prosthesis.

    Product
    M/L Taper Hip Prosthesis Extended Offset, Reduced Neck Length, Size 4 (Item Number 00771100640) and Size 6 (Item Number 00771100440)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2516-2023·2023-09-13

    Fargo Ortho-K Contact Lens Recall Due to Missing FDA Approval

    PARAGON VISION SCIENCES is recalling 18,820 Fargo Ortho-K contact lenses because they were manufactured without required FDA approval. Patients should contact their eye care provider.

    Product
    Fargo Ortho-K Lens
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2522-2023·2023-09-13

    Olympus Distal Attachment Recalled for Phthalate Exceeding Permissible Levels

    Aomori Olympus Co., Ltd. recalls 1,048 Olympus Distal Attachment units used in EMR kits due to di-2-ethylhexyl phthalate (DEHP) exceeding permissible exposure limits per ISO 10993-17: 2002. Devices were distributed nationwide.

    Product
    Olympus Distal Attachment (in Olympus Disposable EMR Kit)- Designed to be attached to the distal end of the endoscope. Disposable EMR Kit: K-001, K-002, K-003, K-004, K-011, K-012
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2403-2023·2023-09-13

    Azurion imaging systems recalled for stuck foot switch causing unintended radiation

    Philips recalls Azurion imaging systems because the foot switch pedal may stick in the active position, causing unintended radiation emission. Facilities should stop using the systems and contact Philips for guidance.

    Product
    Azurion
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2517-2023·2023-09-13

    Philips 3D9-3v Ultrasound Transducer may separate due to bonding defect

    Philips 3D9-3v Transducer units may separate at the chassis bonding, risking electric shock and tissue damage if safety systems fail. Affected units distributed worldwide.

    Product
    3D9-3v Transducer, accessory to Philips Ultrasound Systems: EPIQ Elite; Affiniti 30, 50, and 70; ClearVue 850; HD15; iU22; and Compact 5000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2404-2023·2023-09-13

    Medical Imaging System Recalled for Foot Pedal Malfunction Risk

    Philips MultiDiagnost-Eleva imaging systems may emit unintended radiation if the foot pedal gets stuck in the active position. The FDA is alerting healthcare facilities to this potential equipment malfunction.

    Product
    MultiDiagnost-Eleva
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2402-2023·2023-09-13

    Philips Allura Xper X-ray Systems Foot Pedal May Stick, Causing Unintended Radiation

    Philips Allura Xper X-ray imaging systems are being recalled because the foot switch pedal may become stuck in the active position, potentially causing unintended radiation emission. The recall affects 5,432 systems distributed nationwide.

    Product
    Allura Xper series
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2521-2023·2023-09-13

    ZVU Functional GI Software Recall for Incorrect Software Revision Labeling

    ZVU Functional GI Software labeled as revision 3.3.0 is incorrectly labeled; it actually contains revision 3.2.0. The mislabeling affects 20 units distributed from May to July 2023.

    Product
    ZVU Functional GI Software, REF: ZVU-3
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2431-2023·2023-09-06

    Cardiosave Hybrid Intra-Aortic Balloon Pump charging issue recall

    The Cardiosave Hybrid Intra-Aortic Balloon Pump console fails to charge if not fully inserted into the hospital cart. Users unaware of this requirement may attempt to use a non-charged device during critical cardiac care.

    Product
    Cardiosave Hybrid Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-31, 0998-UC-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-UC-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-UC-0800-52, 0998-00-0800-53, 0998-UC-0800-53, 0998-00-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2433-2023·2023-09-06

    Cardiosave Hybrid IABP devices recalled for temperature and pumping function failures

    Datascope is recalling Cardiosave Hybrid intra-aortic balloon pumps due to reported temperature alarms that can cause loss of pumping function or unexpected standby mode. Users have reported these system failures in critical cardiac support devices.

    Product
    Cardiosave Hybrid Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-31, 0998-UC-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-UC-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-UC-0800-52, 0998-00-0800-53, 0998-UC-0800-53, 0998-00-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2467-2023·2023-09-06

    EVIS EXERA III Duodenovideoscope Recalled Due to Patient Infection Reports

    Olympus Corporation recalls 6,426 units of the EVIS EXERA III Duodenovideoscope (Model TJF-Q190V) due to recent reports of patient infections. The device was distributed nationwide in the United States.

    Product
    EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190V
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2435-2023·2023-09-06

    Intra-Aortic Balloon Pumps recalled for unexpected gas loss and gain alarms

    Datascope's Cardiosave Hybrid Intra-Aortic Balloon Pumps may trigger unexpected alarms indicating gas loss or gain due to undocumented causes including patient movement and blood in the circuit. The FDA Class I recall affects 9,175 units.

    Product
    Cardiosave Hybrid Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-31, 0998-UC-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-UC-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-UC-0800-52, 0998-00-0800-53, 0998-UC-0800-53, 0998-00-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2432-2023·2023-09-06

    Cardiosave Rescue Intra-Aortic Balloon Pumps Fail to Charge When Improperly Inserted

    Datascope Corp. is recalling 9,175 units of Cardiosave Rescue IABP devices because batteries will not charge if the console is not fully inserted into the hospital cart. Users were often unaware of this insertion requirement.

    Product
    Cardiosave Rescue Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2436-2023·2023-09-06

    Cardiosave Rescue IABP Alarms May Trigger Unexpectedly During Therapy

    Datascope Corp. is recalling approximately 9,175 Cardiosave Rescue IABPs because unexpected gas-loss and gas-gain alarms may occur during therapy due to patient movement, blood in the circuit, and hardware issues.

    Product
    Cardiosave Rescue Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85
    Category
    Medical Device
    Distribution
    Distributed nationwide