Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

8701–8725 of 40007

  • HighFDA (Devices)·Z-0296-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recall for Battery Pin Loosening

    Physio-Control, Inc. is recalling LIFEPAK 15 defibrillators (Part Number V15-2-000051) because battery pins may loosen and cause power failure. Affected devices should not be used until repaired.

    Product
    LIFEPAK 15, REF: 99577-000046, Part Number V15-2-000051
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0313-2024·2023-11-22

    Blood Culture Kits Recalled Due to Expired Internal Components

    Medline Industries is recalling 3,160 units of 24 Blood Culture Kits because components within the kit have expired before the overall kit's stated expiration date. Expired components may compromise device performance or test result accuracy.

    Product
    24 BLOOD CULTURE KIT, REF DYNDH1632
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0309-2024·2023-11-22

    Medical Device Reagent Recalled for Unreliable Test Results

    Beckman Coulter's Transferrin reagent lot 2573 does not maintain stability as claimed, causing unreliable patient test results and control failures. The company confirmed the issue affects diagnostic accuracy.

    Product
    AU/DxC AU Chemistry Transferrin REF: OSR6152 Immune complexes formed in solution scatter light in proportion to their size, shape and concentration. Turbidimeters measure the reduction of incident light due to reflection, absorption, or scatter. In the procedure, the measurement
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0302-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recalled for Loose Battery Pins Causing Power Loss

    Physio-Control is recalling LIFEPAK 15 defibrillators due to a potential for battery pins to become loose, which could cause power failure.

    Product
    LIFEPAK 15, REF: 99577-001956, Part Number V15-7-000021
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0315-2024·2023-11-22

    Cardiovascular Convenience Kit Recalled for Inadequate Chest Drain Instructions

    ROi CPS LLC is recalling Regard CV PK cardiovascular convenience kits due to insufficient instructions for proper chest drain catheter and tube connection setup. 134 units were distributed in Missouri.

    Product
    Regard CV PK, Item Numbers a) 880289014, b) 880289015; cardiovascular convenience kit
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0294-2024·2023-11-22

    CT Scanner Image Fusion Software Error Affecting Radiation Therapy Planning

    A software bug in Philips Brilliance CT scanners causes image-fusion errors, resulting in incorrect radiation therapy coordinates and potential treatment planning failures.

    Product
    Brilliance CT Big Bore Oncology with software version V4.8.0.10421 Model:728243 CT scanner and simulator designed for radiation oncology and therapy.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0307-2024·2023-11-22

    Medical Device Recall: KWIKSTIK Microbiological Reagent Contaminated with Aspergillus

    Microbiologics Inc recalls KWIKSTIK microbiological reagent kits due to Aspergillus flavus contamination in bulk pellets. Affected products were distributed worldwide, including the US, Italy, France, Turkey, Peru, and Mexico.

    Product
    KWIKSTIK, P. venetum, Catalog numbers: a) 0794P (2-pack), b) 0794K (6-pack)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0301-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recalled for Loose Battery Pins Causing Power Loss

    Physio-Control is recalling LIFEPAK 15 defibrillators due to potential loose battery pins that could cause power failure. Four affected units have been distributed to Arizona, California, North Carolina, New Jersey, and New York.

    Product
    LIFEPAK 15, REF: 99577-001955, Part Number V15-5-000584 and V15-7-000020
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0300-2024·2023-11-22

    LIFEPAK 15 Defibrillator Recall: Loose Battery Pins Risk Power Loss

    Physio-Control is recalling LIFEPAK 15 defibrillators due to a potential defect where battery pins may become loose, causing power issues.

    Product
    LIFEPAK 15, REF: 99577-001373, Part Number V15-7-000002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0308-2024·2023-11-22

    Laboratory Culture Disks Recalled for Aspergillus Flavus Contamination

    Microbiologics Inc is recalling LYFO-DISK P. venetum laboratory culture disks (lot 794-142) found contaminated with Aspergillus flavus during complaint investigation. The product was distributed worldwide.

    Product
    LYFO-DISK, P. venetum, Catalog number 0794L
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0223-2024·2023-11-22

    Siemens Mobilett Mira wireless x-ray systems recalled for buzzer mounting defect

    Four Siemens Mobilett Mira wireless mobile x-ray systems are recalled due to incorrect buzzer component mounting that prevents acoustic signals during x-ray activation. The systems remain fully functional with visual LED indicators available for operator monitoring.

    Product
    Mobilett Mira wireless (VA20) mobile x-ray system(s)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0151-2024·2023-11-15

    Novum IQ Syringe Pump may falsely indicate infusion completion

    Baxter's Novum IQ Syringe infusion system may display a false 'Infusion Complete' alarm after multiple occlusion events, leaving uninfused fluid in the syringe and risking incomplete medication delivery.

    Product
    Novum IQ Syringe infusion system, Product Code 40800BAXUS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0191-2024·2023-11-15

    Olympus Bronchovideoscope Recalled for Fire Risk During Cauterization

    Olympus Corporation recalls 13,950 EVIS EXERA II bronchovideoscopes due to risk of endobronchial combustion when high-frequency cauterization is performed with oxygen supplied while the electrode is positioned too close to the endoscope.

    Product
    EVIS EXERA II BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Numbers BF-1T180, BF-1TQ180, BF-P180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0189-2024·2023-11-15

    Five Olympus Bronchovideoscope Models Recalled for Endobronchial Combustion Risk

    Olympus is recalling 15,942 bronchovideoscope units nationwide due to endobronchial combustion risk during cauterization procedures with oxygen supply. The hazard occurs when the electrode of the surgical accessory is positioned too close to the scope's distal end.

    Product
    BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Numbers BF-1T150, BF-1T60, BF-P150 BF-P60 and EVIS EXERA BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Number XT160
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0184-2024·2023-11-15

    Alaris PCA Module 8120 infusion pump recalled for unvalidated syringes

    CareFusion 303, Inc. is recalling the Alaris PCA Module 8120 infusion pump because its labeling lists compatible syringes that have not been validated. This Class I recall affects 867,362 units worldwide.

    Product
    BD Alaris PCU REF 8015
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0190-2024·2023-11-15

    Olympus Bronchovideoscope Recall for Combustion Risk with Electrosurgery

    Olympus is recalling 1,154 EVIS EXERA II bronchovideoscope units due to risk of endobronchial combustion during high-frequency electrosurgical procedures when oxygen is supplied and electrode placement is inappropriate.

    Product
    EVIS EXERA II BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Number Q180-AC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0194-2024·2023-11-15

    FDA Recalls Olympus EVIS EXERA III Bronchovideoscope for Combustion Risk

    Olympus Corporation is recalling 3,948 EVIS EXERA III bronchovideoscope units nationwide due to risk of combustion during electrosurgical procedures when high-frequency cauterization is used with oxygen supply.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS Model Number BF-P190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0286-2024·2023-11-15

    Cordis Cardiac Catheter Sets Distributed Non-Sterile, Labeled Sterile

    Cordis US Corp is recalling cardiac catheter sets (Lot 18223410) distributed in Oklahoma. The devices were non-sterile but labeled as sterile, creating infection risk to patients.

    Product
    Cordis ANGIOGRAPHIC CATHETERIZATION SETS, INFINITI THRULEMEN, 5F, REF CO0208, cardiac catheter
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0193-2024·2023-11-15

    Olympus Bronchovideoscope Recalled Due to Combustion Risk

    Olympus is recalling 719 EVIS EXERA b Bronchovideoscope Model BF-XT190 devices due to risk of endobronchial combustion during high-frequency cauterization when oxygen is supplied or the electrode is too close to the device tip.

    Product
    EVIS EXERA b BRONCHOVIDEOSCOPE OLYMPUS Model Number BF-XT190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0192-2024·2023-11-15

    Olympus Bronchovideoscopes Recalled for Endobronchial Combustion Risk

    Olympus is recalling bronchovideoscopes nationwide due to a risk of combustion inside the bronchial passages during high-frequency cauterization if oxygen is supplied or the electrode is positioned too close to the scope's tip.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE Model Numbers BF-1TH190, BF-H190, BF-Q190 and BRONCHOVIDEOSCOPE OLYMPUS BF-Q170 Model Number BF-Q170
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0188-2024·2023-11-15

    StealthStation S8 Surgical Navigation System Software Anomaly Recall

    Medtronic is recalling StealthStation S8 and FlexENT systems with software versions 2.0 and 2.0.1 due to a software anomaly that could cause surgical planning data to shift to an unintended location.

    Product
    StealthStation S8 Application version 2.0 and 2.0.1 (Part 9735762) The StealthStation System, with StealthStation Cranial software, is intended as an aid for locating anatomical structures in either open or percutaneous neurosurgical procedures. The StealthStation FlexENT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0227-2024·2023-11-15

    Medical imaging systems recalled for missing safety spacer and warning label

    Philips is recalling Integris-Allura IGTS Fixed Systems delivered to Puerto Rico, Guam, and the Virgin Islands due to missing Source-to-Skin Distance Spacers and required warning labels.

    Product
    Integris-Allura IGTS Fixed Systems
    Category
    Medical Device
    Distribution
    3 states