The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

8101–8125 of 27393

  • HighFDA (Devices)·Z-1475-2023·2023-05-10

    Steris surgical light handle covers may detach during procedures

    Steris surgical light handle covers may detach during use, risking contamination of the sterile field and patient injury. The FDA is recalling approximately 1.4 million affected covers.

    Product
    Steris Lighting and Visualization Systems, Sterile Light Handle Cover (LB53)- Surgical light handle covers, including disposable surgical light handle covers are designed to fit over surgical light handles for sterile surgeon control. REF: LB53
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1501-2023·2023-05-10

    Medical Image Viewer May Mismatch Patient Study Records

    GE Healthcare's Centricity Universal Viewer can mismatch patient information when correcting patient or study data, affecting 329 units distributed worldwide.

    Product
    Centricity Universal Viewer, Centricity Universal Viewer 6.0, Model/Catalog Numbers: a) 2088026-003, b) 2088026-026, c) 2088026-032, d) 2088026-043, e) 2088026-044, f) 2088026-115, g) 2088026-132, h) 2088026-306, i) 2088026-308, j) 2088026-406, k) 2088026-506, l) 20
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1523-2023·2023-05-10

    LINK SLED Knee System tibial component recall due to implant positioning and cementing concerns

    Linkbio Corp. is recalling LINK SLED Knee System tibial components due to risk of early loosening or increased wear caused by suboptimal implant positioning or inadequate cementing technique. Surgeons are being directed to update their technique and receive additional training.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 7MM X 58MM Item Number: 15-2028/13
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1549-2023·2023-05-10

    LINK SLED Knee System recalls due to implant loosening risk

    Linkbio Corp. is recalling LINK SLED Knee System implants that may loosen prematurely due to improper positioning or cementing technique. Enhanced surgical training is being provided to prevent early device failure.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 9 MM X 55 MM Item Number: 15-2230/10
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1519-2023·2023-05-10

    LINK SLED Knee System Tibial Component Recall Due to Early Loosening Risk

    Linkbio Corp. is recalling the LINK SLED Knee System ALL POLY TIBIAL COMPONENT due to risk of early aseptic loosening or increased wear from suboptimal surgical placement or cementing, which may require early revision surgery.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 7MM X 55MM Item Number: 15-2028/09
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1533-2023·2023-05-10

    LINK SLED Knee System Recalled for Aseptic Loosening and Implant Wear

    Linkbio Corp. is recalling 12 units of the LINK SLED Knee System due to risk of implant loosening and wear that could require revision surgery sooner than expected.

    Product
    LINK SLED Knee System ENDO MODEL SLED TIBIAL COMP 9 MM X 55 MM Item Number: 15-2030/10
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1530-2023·2023-05-10

    LINK SLED Knee Implant Recall: Risk of Early Loosening and Revision Surgery

    Linkbio Corp. is recalling 14 LINK SLED Knee implants due to risk of aseptic loosening and increased wear caused by improper surgical technique. The implants may fail earlier than expected, requiring revision surgery.

    Product
    LINK SLED Knee System ENDO MODEL SLED TIBIAL COMP 9 MM X 50 MM Item Number: 15-2030/06
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1547-2023·2023-05-10

    Knee implant system recalled due to aseptic loosening and wear risk

    Linkbio Corp. is recalling the LINK SLED Knee System due to risk of early aseptic loosening and increased wear caused by improper surgical technique or positioning. The issue may require early revision surgery.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 11 MM X 50 MM Item Number: 15-2230/07
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1553-2023·2023-05-10

    Knee Implant System Warning: Risk of Early Loosening Due to Surgical Technique

    Linkbio Corp. is updating labeling and surgical technique training for the LINK SLED Knee System to prevent early aseptic loosening or excessive wear caused by improper implant positioning or inadequate cementing during surgery.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 8 MM X 50 MM Item Number: 15-2230/14
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1474-2023·2023-05-10

    SafeLight Fiber Optic Cable Recall Due to Assembly Defect

    Stryker Corporation is recalling SafeLight Fiber Optic Cables due to insufficient epoxy on the proximal end, which can cause light output failure and potentially delay surgical procedures.

    Product
    SafeLight Fiber Optic Cable: Clear, 5MM X 10FT 3.05M, REF: 0233-050-100; Gray, 5MM X 10FT 3.05M, REF: 0233-050-200
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1511-2023·2023-05-10

    Knee implant tibial component recalled for aseptic loosening risk

    Linkbio Corp. recalls LINK SLED Knee System tibial component due to risks of early aseptic loosening and implant wear from improper surgical positioning or cementing technique.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 7MM X 45MM Item Number: 15-2028/01
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1551-2023·2023-05-10

    Knee Implant Component Recalled for Risk of Early Aseptic Loosening

    Linkbio Corp. is recalling the LINK SLED Knee System tibial component due to risk of early aseptic loosening and increased wear caused by suboptimal implant positioning or inadequate cementing technique.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 13 MM X 55 MM Item Number: 15-2230/12
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1499-2023·2023-05-10

    Walgreens assorted bandages recalled for undisclosed ingredient in adhesive

    ASO LLC is recalling Walgreens assorted bandages (item 196568) distributed nationwide due to benzalkonium chloride in the adhesive pad that is not disclosed on the labeling.

    Product
    WALGREENS BANDAGES, item number 196568, 110 CT VALUE PACK, 24 BOXES/MASTER (shipping container), Walgreens Family Pack ASSORTED BANDAGES, 110 ASSORTED SIZES (retail package)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1522-2023·2023-05-10

    Knee Implant Component Recalled for Aseptic Loosening Risk

    Linkbio Corp. recalls 14 units of the LINK SLED Knee System tibial component due to risk of early aseptic loosening and increased wear from suboptimal implant positioning or inadequate cementing technique. Healthcare providers should follow updated surgical guidance.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 13MM X 55MM Item Number: 15-2028/12
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1513-2023·2023-05-10

    Knee Implant System Component Recalled Due to Aseptic Loosening Risk

    Linkbio Corp. is recalling 13 units of the LINK SLED Knee System tibial component due to risk of aseptic loosening and increased wear. These risks arise from improper surgical positioning or inadequate cementing technique during implantation.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 11MM X 45MM Item Number: 15-2028/03
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1535-2023·2023-05-10

    Knee Implant Recalled for Inadequate Surgical Technique Guidance

    Linkbio is recalling 15 LINK SLED Knee Systems due to potential aseptic loosening and wear from suboptimal implant positioning or inadequate cementing during surgery. Updated surgical technique training is required.

    Product
    LINK SLED Knee System ENDO MODEL SLED TIBIAL COMP 13 MM X 55 MM Item Number: 15-2030/12
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1562-2023·2023-05-10

    Laboratory Automation Module Firmware May Cause Sample Misidentification

    Vesmatic Cube 80 laboratory automation system firmware can incorrectly identify patient samples, potentially leading to wrong test results and inappropriate treatment. Affected systems include FlexLab, Accelerator a3600, and Aptio Automation units.

    Product
    Vesmatic Cube 80 Interface Module (VMC)-Laboratory Automation system Brand names of the same product: FlexLab (FLX), Accelerator a3600 (ACP), Aptio Automation (AP2) Part Numbers: 72747000.A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1552-2023·2023-05-10

    Knee Implant Recall for Aseptic Loosening and Implant Wear Risk

    The LINK SLED Knee System is recalled due to risk of early aseptic loosening and implant wear caused by suboptimal surgical positioning or inadequate cementing. The manufacturer is updating surgical guidance and providing additional training.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 8 MM X 45 MM Item Number: 15-2230/13
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1502-2023·2023-05-10

    Radiological imaging system may mismatch patient records

    GE Healthcare's Centricity PACS-IW radiological system can mismatch information between patients when correcting patient or study data. No illnesses reported.

    Product
    Centricity PACS-IW, Product ID Numbers: a) 2041037-001, b) 2042988-001, c) 2049587-009, d) 2049587-011, e) 2049587-012, f) 2049587-015, g) 2052829-001, h) Not applicable; Radiological Image Processing System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1548-2023·2023-05-10

    LINK SLED knee implant system surgical technique amendment for aseptic loosening prevention

    Linkbio Corp. is updating surgical technique guidance for the LINK SLED knee implant system to prevent early aseptic loosening or implant wear caused by suboptimal positioning or cementing technique during surgery.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 13 MM X 50 MM Item Number: 15-2230/08
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1514-2023·2023-05-10

    Knee implant recalled due to early aseptic loosening risk from surgical technique

    LINK SLED Knee System tibial components are being recalled due to risk of early aseptic loosening and increased wear from suboptimal implant positioning or inadequate cementing technique. Surgical technique guidance is being issued.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 13MM X 45MM Item Number: 15-2028/04
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1476-2023·2023-05-10

    Steris Light Handle Covers May Detach During Surgical Use

    Steris Corporation is recalling 263,280 surgical light handle covers worldwide because they may separate from the light handle during procedures, potentially compromising the sterile field.

    Product
    Steris Lighting and Visualization Systems, Sterile Light handle Cover LB44 -Sterilizable consumables (disposable, single use) used to drape the lighthandle of STERIS surgical lighting systems for the purpose of maintaining a sterile surgical environment. REF: LB44
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1505-2023·2023-05-10

    Siemens ADVIA Centaur Cortisol Diagnostic Kits Recalled for Negative Measurement Bias

    Siemens Healthcare Diagnostics is recalling 18,961 ADVIA Centaur Cortisol diagnostic kits due to negative bias in urine samples causing intermittently low test results that could affect clinical diagnosis.

    Product
    ADVIA Centaur Cortisol 50T (Material Number 10994924), ADVIA Centaur Cortisol 250T (Material Number 10994926), and ADVIA Centaur Cortisol REF 250T (Material Number 10994927). In vitro diagnostic use in the quantitative determination of cortisol in human serum, plasma (EDTA and li
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1525-2023·2023-05-10

    LINK SLED Knee Implant Component Recall for Aseptic Loosening Risk

    Linkbio Corp. is recalling the LINK SLED Knee System's all-poly tibial component due to risk of early aseptic loosening and increased wear from suboptimal implant positioning or inadequate cementing during surgery.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 11X58MM Item Number: 15-2028/15
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1536-2023·2023-05-10

    Knee Implant System Recalled for Premature Loosening and Wear Risk

    Linkbio Corp. is recalling LINK SLED Knee System implants that may loosen or wear prematurely due to improper surgical positioning or cementing, potentially requiring revision surgery. Updated surgical technique guidance is being provided.

    Product
    LINK SLED Knee System ENDO MODEL SLED TIBIAL COMP 8 MM X 45 MM Item Number: 15-2030/13
    Category
    Medical Device
    Distribution
    2 states