The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

8076–8100 of 27393

  • HighFDA (Devices)·Z-1516-2023·2023-05-10

    LINK SLED Knee System tibial component subject to surgical technique amendment

    A knee implant component is being recalled due to risks of early loosening or increased wear caused by suboptimal implant positioning or inadequate cementing. Manufacturers are providing updated surgical guidance.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 9MM X 50MM Item Number: 15-2028/06
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1540-2023·2023-05-10

    LINK SLED Knee System recalls issued over aseptic loosening risk

    Linkbio Corp. is recalling LINK SLED Knee System knee components due to risk of early aseptic loosening or increased wear. The company is issuing updated surgical technique guidance to address suboptimal implant positioning and cementing techniques.

    Product
    LINK SLED Knee System POREX ENDO SLED KNEE FEM COMP, MEDIUM SMALL Item Number: 15-2220/46
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1474-2023·2023-05-10

    SafeLight Fiber Optic Cable Recall Due to Assembly Defect

    Stryker Corporation is recalling SafeLight Fiber Optic Cables due to insufficient epoxy on the proximal end, which can cause light output failure and potentially delay surgical procedures.

    Product
    SafeLight Fiber Optic Cable: Clear, 5MM X 10FT 3.05M, REF: 0233-050-100; Gray, 5MM X 10FT 3.05M, REF: 0233-050-200
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1522-2023·2023-05-10

    Knee Implant Component Recalled for Aseptic Loosening Risk

    Linkbio Corp. recalls 14 units of the LINK SLED Knee System tibial component due to risk of early aseptic loosening and increased wear from suboptimal implant positioning or inadequate cementing technique. Healthcare providers should follow updated surgical guidance.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 13MM X 55MM Item Number: 15-2028/12
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1473-2023·2023-05-10

    OttLite UVC Disinfecting Wand Emits Excessive Ultraviolet Radiation

    OttLite Rechargeable UVC Disinfecting Wand model UV10002M emits excessive ultraviolet radiation above safe limits. Approximately 7,376 units were distributed nationwide.

    Product
    OttLite Rechargeable UVC Disinfecting Wand
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1512-2023·2023-05-10

    Knee Implant Recall Due to Risk of Aseptic Loosening and Wear

    Linkbio Corp. is recalling 13 units of the LINK SLED knee implant component due to risk of early aseptic loosening or increased wear caused by suboptimal surgical positioning or inadequate cementing technique. Amended surgical technique guidance has been provided.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 9MM X 45MM Item Number: 15-2028/02
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1504-2023·2023-05-10

    Siemens Atellica cortisol kits recalled for negative bias in urine testing

    Siemens Healthcare Diagnostics recalls 34,746 Atellica IM Cortisol diagnostic kits due to negative bias in urine test results, which may produce inaccurately low cortisol measurements.

    Product
    Atellica IM Cortisol 50T (Material Number 10995538), 250T (Material Number 10995537), and REF 250T (Material Number 11206248). In vitro diagnostic use in the quantitative determination of cortisol in human serum, plasma (EDTA and lithium heparin), and urine.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1544-2023·2023-05-10

    Knee Implant Component Recalled for Surgical Positioning and Cementing Guidance

    FDA is updating surgical instructions for the LINK SLED Knee System to address early aseptic loosening and increased wear from suboptimal positioning or inadequate cementing technique. Updated training aims to prevent implant failure and unexpected revision surgery.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 11 MM X 45 MM Item Number: 15-2230/03
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1518-2023·2023-05-10

    LINK SLED Knee Implant Component Recalled Due to Early Loosening Risk

    FDA recalls LINK SLED Knee System tibial components due to risk of aseptic loosening and premature wear. Patients may require revision surgery.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 13MM X 50MM Item Number: 15-2028/08
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1476-2023·2023-05-10

    Steris Light Handle Covers May Detach During Surgical Use

    Steris Corporation is recalling 263,280 surgical light handle covers worldwide because they may separate from the light handle during procedures, potentially compromising the sterile field.

    Product
    Steris Lighting and Visualization Systems, Sterile Light handle Cover LB44 -Sterilizable consumables (disposable, single use) used to drape the lighthandle of STERIS surgical lighting systems for the purpose of maintaining a sterile surgical environment. REF: LB44
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1521-2023·2023-05-10

    Linkbio Knee Implant Recalled for Aseptic Loosening Risk

    Linkbio Corp. is recalling 15 LINK SLED Knee System implants due to risk of aseptic loosening and wear from improper surgical technique. The company is providing amended surgical guidance and training to prevent implant failure.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 11MM X 55MM Item Number: 15-2028/11
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1501-2023·2023-05-10

    Medical Image Viewer May Mismatch Patient Study Records

    GE Healthcare's Centricity Universal Viewer can mismatch patient information when correcting patient or study data, affecting 329 units distributed worldwide.

    Product
    Centricity Universal Viewer, Centricity Universal Viewer 6.0, Model/Catalog Numbers: a) 2088026-003, b) 2088026-026, c) 2088026-032, d) 2088026-043, e) 2088026-044, f) 2088026-115, g) 2088026-132, h) 2088026-306, i) 2088026-308, j) 2088026-406, k) 2088026-506, l) 20
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1551-2023·2023-05-10

    Knee Implant Component Recalled for Risk of Early Aseptic Loosening

    Linkbio Corp. is recalling the LINK SLED Knee System tibial component due to risk of early aseptic loosening and increased wear caused by suboptimal implant positioning or inadequate cementing technique.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 13 MM X 55 MM Item Number: 15-2230/12
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1526-2023·2023-05-10

    LINK SLED Knee Implant System recalled for early aseptic loosening

    The LINK SLED Knee System ALL POLY TIBIAL COMPONENT (18 units) is recalled due to early aseptic loosening and increased wear caused by suboptimal positioning or inadequate cementing technique, which may require earlier-than-expected revision surgery.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 13X58MM Item Number: 15-2028/16
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1554-2023·2023-05-10

    LINK SLED Knee System tibial implant recalled for aseptic loosening

    Linkbio Corp. recalls LINK SLED Knee System tibial component due to risk of aseptic loosening and implant wear from improper surgical technique, potentially requiring revision surgery.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 8 MM X 55 MM Item Number: 15-2230/15
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1528-2023·2023-05-10

    LINK SLED Knee System tibial component recall for aseptic loosening and wear risk

    Linkbio Corp. is recalling 15 units of the LINK SLED Knee System tibial component for risk of aseptic loosening and wear from improper implant positioning or inadequate cementing technique. Surgical training will be updated.

    Product
    LINK SLED Knee System: ENDO MODEL SLED TIBIAL COMP 11 MM X 45 MM Item Number: 15-2030/03
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1513-2023·2023-05-10

    Knee Implant System Component Recalled Due to Aseptic Loosening Risk

    Linkbio Corp. is recalling 13 units of the LINK SLED Knee System tibial component due to risk of aseptic loosening and increased wear. These risks arise from improper surgical positioning or inadequate cementing technique during implantation.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 11MM X 45MM Item Number: 15-2028/03
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1552-2023·2023-05-10

    Knee Implant Recall for Aseptic Loosening and Implant Wear Risk

    The LINK SLED Knee System is recalled due to risk of early aseptic loosening and implant wear caused by suboptimal surgical positioning or inadequate cementing. The manufacturer is updating surgical guidance and providing additional training.

    Product
    LINK SLED Knee System POREX ENDO MODEL SLED TIBIAL COMP 8 MM X 45 MM Item Number: 15-2230/13
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1532-2023·2023-05-10

    LINK SLED Knee System Tibial Component Recall Due to Early Loosening Risk

    Linkbio Corp. is recalling LINK SLED Knee System tibial components due to risk of early aseptic loosening and increased wear from improper implant positioning or inadequate cementing. Patients may require revision surgery earlier than expected.

    Product
    LINK SLED Knee System ENDO MODEL SLED TIBIAL COMP 13 MM X 50 MM Item Number: 15-2030/08
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1531-2023·2023-05-10

    LINK SLED Knee Implant Recall Due to Loosening and Wear Risks

    Linkbio Corp. is recalling 14 units of LINK SLED Knee System implants due to risk of early aseptic loosening or wear from suboptimal positioning or inadequate cementing. Updated surgical technique training is being issued.

    Product
    LINK SLED Knee System ENDO MODEL SLED TIBIAL COMP 11 MM X 50 MM Item Number: 15-2030/07
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1505-2023·2023-05-10

    Siemens ADVIA Centaur Cortisol Diagnostic Kits Recalled for Negative Measurement Bias

    Siemens Healthcare Diagnostics is recalling 18,961 ADVIA Centaur Cortisol diagnostic kits due to negative bias in urine samples causing intermittently low test results that could affect clinical diagnosis.

    Product
    ADVIA Centaur Cortisol 50T (Material Number 10994924), ADVIA Centaur Cortisol 250T (Material Number 10994926), and ADVIA Centaur Cortisol REF 250T (Material Number 10994927). In vitro diagnostic use in the quantitative determination of cortisol in human serum, plasma (EDTA and li
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1498-2023·2023-05-10

    Angiography System C-Arm Positioning Malfunction May Cause Patient Injury

    Siemens ARTIS pheno angiography systems may misposition the C-arm by 5-10 millimeters when using the reference image positioning function, risking patient and staff crushing injuries. The device may also display inaccurate imaging overlays, potentially causing vessel perforation.

    Product
    ARTIS pheno systems with a Siemens Healthineers table or Trumpf/MAQUET table (OEM)- Angiography systems developed for single and biplane diagnostic imaging and interventional procedures. Model: 10849000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1524-2023·2023-05-10

    LINK SLED Knee System tibial component subject to early loosening recall

    Linkbio Corp. is recalling the LINK SLED Knee System tibial component (15 units) due to risk of early loosening and increased wear from inadequate surgical technique, potentially requiring earlier-than-expected revision surgery.

    Product
    LINK SLED Knee System: ALL POLY TIBIAL COMPONENT 9X58MM Item Number: 15-2028/14
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1562-2023·2023-05-10

    Laboratory Automation Module Firmware May Cause Sample Misidentification

    Vesmatic Cube 80 laboratory automation system firmware can incorrectly identify patient samples, potentially leading to wrong test results and inappropriate treatment. Affected systems include FlexLab, Accelerator a3600, and Aptio Automation units.

    Product
    Vesmatic Cube 80 Interface Module (VMC)-Laboratory Automation system Brand names of the same product: FlexLab (FLX), Accelerator a3600 (ACP), Aptio Automation (AP2) Part Numbers: 72747000.A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1535-2023·2023-05-10

    Knee Implant Recalled for Inadequate Surgical Technique Guidance

    Linkbio is recalling 15 LINK SLED Knee Systems due to potential aseptic loosening and wear from suboptimal implant positioning or inadequate cementing during surgery. Updated surgical technique training is required.

    Product
    LINK SLED Knee System ENDO MODEL SLED TIBIAL COMP 13 MM X 55 MM Item Number: 15-2030/12
    Category
    Medical Device
    Distribution
    2 states