The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7526–7550 of 40007

  • HighFDA (Devices)·Z-1516-2024·2024-04-17

    PEG feeding tube with blocked connector may impede placement procedure

    Boston Scientific's EndoVive 20Fr PEG Kit may have a blocked connector that prevents the guidewire from advancing during placement, potentially causing complications including bleeding and aspiration.

    Product
    EndoVive 20Fr Push Standard PEG Kit (Box 2)-Indicated for enteral nutrition directly into the stomach in both pediatric and adult patients who are unable to consume nutrition by conventional means. UPN: M00568211
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1515-2024·2024-04-17

    Feeding tube kit recalled due to blocked connector preventing guidewire advancement

    Boston Scientific's EndoVive 20Fr PEG kit may have a blocked connector preventing proper guidewire advancement during placement, potentially requiring emergency intervention.

    Product
    EndoVive 20Fr Push Safety PEG Kit (Box 2)-Indicated for enteral nutrition directly into the stomach in both pediatric and adult patients who are unable to consume nutrition by conventional means. UPN: M00566471
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1510-2024·2024-04-17

    Hillrom Welch Allyn Spot Vision Screener recalled for power cord insulation defect

    Hillrom Welch Allyn Spot Vision Screener VS100 units recalled due to power cord insulation that does not meet electrical safety standards. The affected devices may pose an electrical hazard to users.

    Product
    Hillrom Welch Allyn Spot Vision Screener VS100, marketed under the following models: a) SPOT VISION SCREENER,W/O CASE,PLUG2/EUR, VS100-2; b) SPOT VISION SCREENER,W/O CASE,PLUG4/UK, VS100-4; c) SPOT VISION SCREENER,W/O CASE,PLUG7/SA, VS100-7; d) SPOT VISION SCREENER,W/CAS
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1511-2024·2024-04-17

    Baxter Power Cords Recalled for Electrical Insulation Non-Compliance

    Baxter Healthcare is recalling power cord models globally because the insulation does not meet electrical safety standards, creating a potential risk of electrical shock or fire.

    Product
    Power Cords, marketed under the following models: a) CORD,METAL EARTH PIN, 2.5A,250V,2.5M,C7, 714682; b) PLFM CLASS II POWER CORD - AUSTRALIA, 716010; c) PLFM CLASS II POWER CORD - EUROPE, 716012; d) POWER CORD,AUSTRALIA,2.5A,250V,2.5M,C7, 008-0910-00; e) POWER CORD,E
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1355-2024·2024-04-10

    Mojo 2 CPAP Masks Recalled Worldwide for Magnet Safety Contraindication Update

    SleepNet Corporation is recalling Mojo 2 Full Face CPAP masks (1,268 units worldwide) to update contraindications and warning language due to magnets in the masks. The FDA classified this as a Class I recall.

    Product
    Mojo 2 Full Face AAV Non Vented Mask, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1352-2024·2024-04-10

    Mojo Non Vented Full Face Mask warning updated for magnet hazard

    SleepNet is updating safety warnings and contraindications for its Mojo Non Vented Full Face Mask due to magnet content. All 11,874 affected units are subject to this warning update.

    Product
    Mojo Non Vented Full Face Mask with Headgear, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1357-2024·2024-04-10

    Phantom 2 Nasal Vented Mask recalled due to magnetic device interference risk

    SleepNet is recalling the Phantom 2 Nasal Vented Mask to update contraindications and warning information related to magnets in the device. The recall affects 2,417 units distributed worldwide.

    Product
    Phantom 2 Nasal Vented Mask
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1351-2024·2024-04-10

    Mojo Full Face CPAP Mask Recall: Magnet Safety Update

    SleepNet Corporation is recalling 23,042 Mojo Full Face CPAP masks worldwide because the masks contain magnets that require updated contraindications and warning language.

    Product
    Mojo Full Face with Headgear, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1356-2024·2024-04-10

    iQ 2 Nasal Vented Mask Recalled for Magnet Safety Warnings

    SleepNet Corporation is recalling the iQ 2 Nasal Vented Mask due to magnets requiring updated contraindication and warning language. Approximately 2,477 units distributed worldwide are affected.

    Product
    iQ 2 Nasal Vented Mask
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1353-2024·2024-04-10

    Mojo 2 Full Face Vented Mask Recalled: Magnet Contraindications Updated

    SleepNet Corporation is recalling 2,787 units of the Mojo 2 Full Face Vented Mask due to updates needed for contraindications and warning language regarding magnets in the device. Worldwide distribution.

    Product
    Mojo 2 Full Face Vented Mask, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1354-2024·2024-04-10

    Mojo 2 Full Face Non Vented Mask Recalled for Magnet Safety Concerns

    SleepNet Corporation is recalling Mojo 2 Full Face Non Vented Masks due to magnets in the device and updated contraindications and warnings. The recall affects 2,107 units distributed worldwide.

    Product
    Mojo 2 Full Face Non Vented Mask, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1442-2024·2024-04-10

    Centurion Manual Surgical Kits Recalled Due to Weak Seal

    Medline Industries is recalling Centurion manual surgical kits due to weak seals that may compromise sterility. Approximately 7,950 units were distributed nationwide and internationally.

    Product
    Centurion manual surgical kits labeled as: a) ST. VIRTUS SPLINTER FORCEP 6" (SF8246), Product Code 66580; b) DEBRIDEMENT TRAY, Product Code I86630; c) BIOPSY INSTRUMENT PACK, Product Code I86690; d) DEBRIDEMENT TRAY, Product Code I86815; e) IR ADSON FORCEP & NEEDLE HOLD
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1424-2024·2024-04-10

    Exactech Equinoxe Reverse Shoulder Humeral Liner Recall Due to Nonconforming Packaging

    Exactech is recalling 1,970 Equinoxe Reverse Shoulder humeral liners distributed nationwide and internationally due to nonconforming packaging that lacks required oxygen barrier protection. Affected devices may have compromised sterile barriers.

    Product
    Exactech Equinoxe REVERSE SHOULDER,46mm Humeral Liner, a) +0mm, Item number 320-46-00, b) +2.5mm, Item Number 320-46-03; Shoulder Arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1428-2024·2024-04-10

    Medline Pediatric Magill Catheter Recalled for Weak Seal Risk

    Medline is recalling its Centurion FCP Magill Catheter (7.5 in. pediatric) because the product may have a weak seal that could compromise sterility. The affected units were distributed in the US, Panama, and Canada.

    Product
    Centurion FCP MAGILL CATH 7.5 IN PED (67575), Product Code 67575
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1435-2024·2024-04-10

    Centurion Surgical Hook Kits Recalled Due to Weak Seal

    Medline Industries is recalling 1,520 Centurion surgical hook kits worldwide due to weak seals that may compromise sterility. The seal defect may not be detectable by users.

    Product
    Centurion hook kits labeled as: a) STERILE SKIN HOOK FINE (EA3975F), Product Code 66660; b) STERILE SMALL 2 PRONG SKIN HOOK (25754), Product Code 67105; c) STERILE NEWS TRACH HOOK(83300), Product Code 67810; d) STERILE LILLIE EAR HOOK DELICATE 7", Product Code I68655
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1439-2024·2024-04-10

    Centurion Curette kits recalled for weak seals potentially compromising sterility

    Medline Industries is recalling Centurion Curette kits because some may have weak seals that could compromise product sterility. The weak seal may not be detectable during inspection.

    Product
    Centurion Curette kits labeled as: a) STERILE BUCK EAR CURETTE "00" (25697), Product Code 66745; b) STERILE "1" EAR CURETTE (505629), Product Code 67050; c) STERILE FOX DERMAL CURETTE, 5MM(32923), Product Code 67430; d) STERILE EXCAVATOR CURETTE (P/S), Product Code I67970
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1449-2024·2024-04-10

    Centurion Manual surgical kits recalled due to weak seals risking sterility breach

    Medline's Centurion Manual surgical kits may have weak seals that fail to maintain sterility. If seals breach, microorganisms could contaminate the sterile contents, posing infection risk during surgery.

    Product
    Centurion Manual surgical kits labeled as: a) STERILE S/B WIRE SCISSOR, Product Code 65140; b) SHARP/SHARP SCISSORS 41/2", Product Code 65840; c) STERILE WIRE CUTTER (WCS144), Product Code 66240; d) STERILE LISTER BANDAGE SCISSOR (LS122), Product Code 66855; e) STERILE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1470-2024·2024-04-10

    Covidien Auto Suture Blunt Tip Trocar Seal Disengagement Recall

    Covidien Auto Suture Blunt Tip Trocar units may experience seal disengagement when mesh products are used incorrectly with the device. Healthcare facilities should discontinue use of affected units and contact Covidien for guidance.

    Product
    Covidien Auto Suture" Blunt Tip Trocar, Product Number OMS-T10BT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1471-2024·2024-04-10

    Covidien Trocar Recall Due to Potential Seal Disengagement with Mesh

    Covidien recalls 44,777 Auto Suture Blunt Tip Trocars worldwide due to potential seal disengagement when mesh products are used incorrectly with the device.

    Product
    Covidien Auto Suture" Blunt Tip Trocar, Product Number OMS-T12BTNL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1419-2024·2024-04-10

    Exactech Equinoxe Shoulder Implants Recalled Due to Nonconforming Oxygen Barrier Packaging

    Exactech is recalling 7,213 units of Equinoxe REVERSE SHOULDER prosthetic liners due to nonconforming packaging. The vacuum bags lack the required oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH) specified for these devices.

    Product
    Exactech Equinoxe REVERSE SHOULDER,38mm Constrained Humeral Liner: a) +0mm, Item Number 320-38-10, b) +2.5mm, Item Number 320-38-13, Shoulder Arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1405-2024·2024-04-10

    Exactech Equinoxe Shoulder Components Recalled for Packaging Defect

    Exactech is recalling 6,840 units of Equinoxe shoulder implant components because their vacuum packaging lacks the required oxygen barrier layer (EVOH). The defect could potentially allow material degradation during storage.

    Product
    Exactech Equinoxe GLENOID,KEELED, CEMENTED,47, 50, 53 head, beta curvature, Sizes: a) Small, Item Number 314-02-12, b) Medium, Item Number 314-02-13, c) Large, Item Number 314-02-14, d) Extra Large, Item Number 314-02-15, Shoulder Arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1426-2024·2024-04-10

    Torrent Suite Dx Software versions affected by cybersecurity vulnerability

    Life Technologies Corporation is recalling Torrent Suite Dx Software versions 5.14 and earlier due to a cybersecurity vulnerability that could allow unauthorized access to alter instrument settings, configurations, software, or data.

    Product
    Torrent Suite Dx Software versions 5.14 and earlier used in connection with Ion PGM DX Systems-IVD intended for targeted sequencing of human genomic DNA (gDNA) from peripheral whole-blood samples and DNA and RNA extracted from formalin-fixed, paraffin-embedded (FFPE) samples. The
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1425-2024·2024-04-10

    Exactech Shoulder Implant Liners Recalled for Defective Oxygen Barrier Packaging

    Exactech has recalled 591 units of Equinoxe Reverse Shoulder humeral liners because the packaging lacks a required oxygen barrier layer (EVOH). The nonconforming packaging may affect material integrity of these surgical implants.

    Product
    Exactech Equinoxe REVERSE SHOULDER,46mmConstrained Humeral Liner, a) +0mm, Item number 320-46-10, b) +2.5mm, Item Number 320-46-13; Shoulder Arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1410-2024·2024-04-10

    Exactech Shoulder Implants Recalled for Improper Packaging Defect

    Exactech Equinoxe glenoid shoulder implants were packaged with non-conforming bags lacking an oxygen barrier layer (EVOH), creating potential risk of material degradation. The Class II recall affects 180 units distributed nationwide and internationally.

    Product
    Exactech Equinoxe GLENOID,POSTERIOR AUGMENT, PEGGED, 16o, LEFT, FOR CEMENTED USE ONLY, Mates with: a) 38, 41, 44, 47 head, Small, Item Number 314-06-22, b) 41, 44, 47, 50 head, Medium, Item Number 314-06-23, c) 44, 47, 50, 53 head, Large, Item Number 314-06-24, d) 44,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1436-2024·2024-04-10

    Centurion Scalpel Handles Recalled Due to Weak Seal Risk

    Medline Industries is recalling Centurion scalpel handle kits due to weak seals that may compromise sterility. Users cannot always detect the defect.

    Product
    Centurion scalpel handle kits labeled as: a) STERILE # 3 SCALPEL HANDLE, Product Code 66825; b) STERILE PAS #3 BLADE HANDLE (BH3PAS), Product Code I68290
    Category
    Medical Device
    Distribution
    Distributed nationwide