The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7376–7400 of 27393

  • HighFDA (Devices)·Z-2286-2023·2023-08-09

    Scican STATCLAVE G4 Chamber Autoclave Recall for Sterilization Risk

    Scican has recalled 3 STATCLAVE G4 tabletop autoclaves due to risk of incomplete sterilization if used with incompatible loads. Healthcare facilities should verify only compatible materials are sterilized.

    Product
    STATCLAVE G4 Chamber Autoclave -Tabletop steam sterilizer intended for use by a health care provider to sterilize medical products by means of pressurized steam. Model: G4 622303
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2264-2023·2023-08-09

    Olympus SPiN Drive Forceps Recalled for EM Sensor Malfunction

    Olympus SPiN Drive Forceps are being recalled due to an electromagnetic sensor malfunction that disables navigation functionality during endobronchial procedures, potentially causing procedural delays. No injuries reported.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) Forceps, 1.8mm OD, Serrated Cup-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing Model: INS-0
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2334-2023·2023-08-09

    Medline sterile procedural kits recalled for potential sterility specification failures

    Medline is recalling custom sterile and non-sterile procedural kits containing Turkuaz Ultrasound Gel due to potential sterility specification failures. The kits were distributed worldwide to hospitals and medical facilities.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. C V MINOR PACK, Model Number: DYNJ64862A; b. DBD-C SECTION ADM, Model Number: DYKL1816; c. FETAL SURGERY, Model Number: DYNJ908118A;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2252-2023·2023-08-09

    Fusion Lithotripsy Extraction Baskets recalled for mechanical defects

    Wilson-Cook Medical's Fusion Lithotripsy Extraction Baskets are being recalled due to mechanical defects that can prevent the basket from advancing or retracting, or cause the drive wire to break or separate during use.

    Product
    Fusion Lithotripsy Extraction Basket, Model Number FS-LXB-2X4 G48277; Fusion Lithotripsy Extraction Baskets are intended to be used for endoscopic removal of biliary stones and foreign bodies.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2338-2023·2023-08-09

    Medline procedural kits recalled for ultrasound gel sterility concerns

    Medline is recalling 15,323 custom sterile and non-sterile procedural kits worldwide due to potential non-sterility of the Turkuaz ultrasound gel component. Kits were distributed between April 2020 and April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ANGIOGRAPHY PACK, Model Number: DYNJ65963A; b. ARTHOGRAM TRAY, Model Number: PAIN1524B; c. ARTHROGRAM TRAY, Model Number: PAIN1524A; d. CARPAL TUNNEL K
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2298-2023·2023-08-09

    Medical procedural kits recalled due to sterility concerns with ultrasound gel

    Medline recalls 76,870 procedural kits because the ultrasound gel component may not meet sterility standards. Kits were distributed nationwide and internationally from April 2020 through April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. CRMC MINOR IR PROCEDURE PK-LF, Model Numbers: DYNJ61099B, DYNJ61099C; b. CRMC TUNNEL CATH TRAY-LF, Model Numbers: DYNJ61118C, DYNJ61118F; c. CUSTOM ANGIO TRAY, M
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2260-2023·2023-08-09

    Philips Incisive CT Scanner Mounting Box Poses Injury Risk

    A metal mounting box in the Incisive CT Power scanner may detach and potentially injure operators or cause system failure. Philips is recalling 53 affected units distributed worldwide.

    Product
    Incisive CT Power (China)-Computed Tomography X-Ray System Model: 728148
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2280-2023·2023-08-09

    NanoZoomer S360MD Slide Scanner May Record Incorrect Barcode Information

    Hamamatsu's NanoZoomer S360MD slide scanner may record incorrect barcode information in the NDPi file, potentially causing pathologists to reference the wrong patient's digital slide image.

    Product
    NanoZoomer S360MD Slide scanner system-automated system for creating, viewing, and managing digital slides. The NanoZoomer System creates diagnostic-quality digital images of glass slides containing formalin-fixed paraffin-embedded (FFPE) tissue. Catalog Number: C13220-01MD
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2247-2023·2023-08-09

    VERITAS Advanced Infusion and Fluidics Packs Recalled for Weld Defect

    Johnson & Johnson is recalling 148,941 VERITAS Advanced Infusion and Fluidics surgical packs due to weld defects that could cause vacuum failure during surgery, potentially leading to surgical delays and temporary eye swelling.

    Product
    VERITAS Advanced Infusion Packs (VRT-AI) and VERITAS Advanced Fluidics Packs (VRT-AF)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2256-2023·2023-08-09

    Siemens Pro.specta Emission CT Systems Sensor Issue Reduces Image Resolution

    Siemens Pro.specta CT imaging systems may produce reduced image quality due to sensors triggering earlier than expected, potentially affecting diagnostic accuracy. Affected units were distributed across the US and internationally.

    Product
    The following Pro.specta Emission Computed Tomography Systems that were manufactured with an SLD Look Ahead Optical Sensor Assembly: (a) Symbia Pro.specta Q3, Model 11364751; (b) Symbia Pro.specta X3, Model 11364752; (c) Symbia Pro.specta X7, Model 11364753.
    Category
    Medical Device
    Distribution
    7 states
  • CriticalFDA (Devices)·Z-2216-2023·2023-08-02

    Intra-Aortic Balloon Catheter Introducer Dilator Fracture During Insertion

    The YAMATO PLUS intra-aortic balloon catheter's introducer dilator may fracture during insertion, risking arterial damage, aortic damage, or blood clots. Datascope has received 10 complaints, including 1 death and 3 serious adverse events.

    Product
    YAMATO PLUS IAB; intra-aortic balloon catheter and accessories used to provide counter pulsation therapy in the aorta. Product Description Part Number YAMATO PLUS-R 30cc IAB WITH ACCESSORIE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2220-2023·2023-08-02

    MEGA Intra-Aortic Balloon Catheter Introducer Fracture Poses Arterial Injury Risk

    Datascope's MEGA 8Fr. intra-aortic balloon catheter introducer may fracture during insertion, leaving fragments that can damage blood vessels. The firm has reported 10 complaints, including 1 death.

    Product
    MEGA 8Fr. IAB, Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number MEGA 8Fr. 50cc IAB WITH STATLOCK D68
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2223-2023·2023-08-02

    LINEAR intra-aortic balloon catheter introducer dilator fracture risk

    Datascope's LINEAR intra-aortic balloon catheters may develop a fractured introducer dilator that can injure blood vessels or cause dangerous blockages. The company has received 10 complaints including 1 death and 3 serious adverse events.

    Product
    LINEAR 7.5Fr.IAB, Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number LINEAR 7.5Fr. 34cc IAB WITH ACCES
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2218-2023·2023-08-02

    Intra-Aortic Balloon Catheter Introducer Dilator May Fracture During Insertion

    Datascope TRANS-RAY IAB catheters may have introducer dilators that fracture during insertion, risking arterial damage or blood clots. The firm reports 1 death and 3 serious injuries.

    Product
    TRANS-RAY IAB, Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number 7FR. 34cc TRANS-RAY IAB WITH ACCESSORIES D684-00-0545-01 TRANS-RAY 7FR. 4
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2222-2023·2023-08-02

    Intra-aortic balloon catheter recall due to introducer dilator fracture risk

    Datascope Corp. is recalling SENSATION PLUS 8Fr. intra-aortic balloon catheters because the introducer dilator may fracture during insertion, risking blood vessel damage and surgical intervention. The company received 10 complaints, including 1 death.

    Product
    SENSATION PLUS 8Fr. IAB, Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number SENSATION PLUS 8Fr. 50cc I
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2219-2023·2023-08-02

    Intra-Aortic Balloon Catheter kits recalled due to dilator fracture risk

    Datascope's MEGA 7.5Fr. intra-aortic balloon catheter kits may have introducers that fracture during insertion, risking arterial damage and embolization. The firm has received 10 complaints including 3 serious events and 1 death.

    Product
    MEGA 7.5Fr.IAB , Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number MEGA 7.5Fr. 40cc IAB WITH ACCESSOR
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2217-2023·2023-08-02

    Datascope SENSATION 7 Intra-Aortic Balloon Catheters Recalled for Introducer Fracture Risk

    The SENSATION 7 Fr. intra-aortic balloon catheter introducer dilator may fracture during insertion, potentially damaging blood vessels and requiring surgery. One death has been reported among 10 total complaints.

    Product
    SENSATION 7 Fr. IAB, Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number SENSATION 7 Fr. 34cc IAB WITH ACCESSORIES (CHINA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2221-2023·2023-08-02

    Datascope SENSATION PLUS Intra-Aortic Balloon Catheter Dilator Fracture Risk

    Datascope's SENSATION PLUS intra-aortic balloon catheter dilator may fracture during insertion, potentially damaging the femoral artery or aorta. The firm has received 10 complaints, including 3 serious adverse events and 1 patient death.

    Product
    SENSATION PLUS 7.5Fr IAB, Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number SENSATION PLUS 7.5Fr. 40c
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2224-2023·2023-08-02

    Intra-Aortic Balloon Catheter Introducer Set fracture causes vascular injury

    Datascope Corp. recalls Reinforced Introducer Sets because the dilator may fracture during catheter insertion, risking arterial damage and embolization. One patient death has been reported.

    Product
    REINFORCED INTRODUCER SET, Intra-Aortic Balloon Catheter and Accessories, used to provide counter pulsation therapy in the aorta Product Description Part Number REINFORCED INTRODUCER SE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2140-2023·2023-08-02

    HAMILTON T1 Ventilator software defect may cause unexpected shutdown

    Hamilton Medical is recalling 2,319 HAMILTON T1 Ventilators due to a software anomaly that may cause the device to stop and enter ambient mode after approximately 91 days of use.

    Product
    HAMILTON T1 Ventilator REF 161006 1610060 161009 1610090 Is intended to provide positive pressure ventilatory support to adults and pediatrics, and optionally infants and neonates
    Category
    Medical Device
    Distribution
    50 states
  • SevereFDA (Devices)·Z-2139-2023·2023-08-02

    HAMILTON C1 Ventilator Recalled for Software Defect Causing Unexpected Shutdown

    Hamilton Medical is recalling 689 HAMILTON C1 Ventilators due to a software defect that causes unexpected shutdown after approximately 91 days of use. The device may enter ambient mode without notice, interrupting ventilatory support.

    Product
    HAMILTON C1 Ventilator REF 161001 1610010 Is intended to provide positive pressure ventilatory support to adults and pediatrics, and optionally infants and neonates
    Category
    Medical Device
    Distribution
    50 states
  • SevereFDA (Devices)·Z-2141-2023·2023-08-02

    Hamilton C2 Ventilator recalled for software anomaly causing loss of function

    FDA is recalling 399 Hamilton C2 Ventilators due to a software anomaly that may cause the device to stop unexpectedly after approximately 91 days of use. Affected facilities should verify serial numbers and contact the manufacturer.

    Product
    HAMILTON C2 Ventilator Is intended to provide positive pressure ventilatory support to adults and pediatrics, and optionally infants and neonates
    Category
    Medical Device
    Distribution
    50 states
  • SevereFDA (Devices)·Z-2142-2023·2023-08-02

    Hamilton C3 ventilator software anomaly may cause unexpected device stoppage

    A software anomaly in the Hamilton C3 Ventilator may cause it to unexpectedly stop and enter ambient mode without warning after approximately 91 days of use. Approximately 701 systems are affected.

    Product
    HAMILTON C3 Ventilator REF 160005 Is intended to provide positive pressure ventilatory support to adults and pediatrics, and optionally infants and neonates
    Category
    Medical Device
    Distribution
    50 states
  • HighFDA (Devices)·Z-2231-2023·2023-08-02

    Flexiva Pulse ID Laser Fiber Recalled for Incorrect Component

    Boston Scientific is recalling Flexiva Pulse ID laser fibers due to an incorrect component that reduces power output and aiming beam brightness. The component can overheat, risking burns to users who touch the fiber connector.

    Product
    Flexiva Pulse ID-intended to be used as a device that transmits Ho:YAG laser energy from cleared laser consoles to urological anatomy Single-pack UPN: M006L8406910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2230-2023·2023-08-02

    Laser Fiber Devices May Overheat and Cause Burns During Use

    Boston Scientific is recalling Flexiva Pulse 242 laser fibers due to manufacturing defects that may cause the fiber connector to overheat and cause burn injuries. The recall affects 1,245 units distributed in the US and Canada.

    Product
    Flexiva Pulse 242 TracTip Single-Use Laser Fibers -intended to be used as a device that transmits Ho:YAG laser energy from cleared laser consoles to urological anatomy. 5-pack UPN: M006L8405961
    Category
    Medical Device
    Distribution
    Distributed nationwide