The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7326–7350 of 13666

  • SevereFDA (Devices)·Z-0864-2024·2024-02-07

    Smiths Medical Medfusion 4000 Syringe Pump Software Defects Recall

    The FDA is recalling Smiths Medical Medfusion Model 4000 syringe pumps due to software defects affecting medication delivery, alarms, and display accuracy. Users should install the latest software version to correct these issues.

    Product
    smiths medical Medfusion Model 4000 syringe pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0940-2024·2024-02-07

    Olympus EZDilate Endoscopic Dilation Balloons Recalled for Device Failures

    Olympus is recalling 2,991 EZDilate endoscopic balloons for problems with inflation and deflation. Reports include device bursting and leaking, and retained foreign bodies in patients during procedures.

    Product
    EZDilate Wire Guided Balloon 8.5-9.5-10.5. indicated for endoscopic dilation of strictures in the alimentary tract in adults and adolescents (>12 years) Model: BD-410X-1055
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0939-2024·2024-02-07

    EZDilate Wire Guided Balloon Recalled for Device Malfunction Issues

    Olympus recalls EZDilate Wire Guided Balloon devices used for endoscopic dilation due to reported bursting, leaking, and retrieval failures affecting 1,639 units nationwide.

    Product
    EZDilate Wire Guided Balloon 6-7-8. indicated for endoscopic dilation of strictures in the alimentary tract in adults and adolescents (>12 years) Model: BD-410X-0855
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0774-2024·2024-02-07

    EVair Air Compressors Recalled for Elevated Formaldehyde Emissions

    EVair air compressors (models M1230849, M1230847) made by Datex-Ohmeda are being recalled after testing detected elevated formaldehyde emissions. The compressors are used with CARESCAPE R860 and Engström ventilator systems.

    Product
    EVair air compressor, model numbers: M1230849 and M1230847
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0941-2024·2024-02-07

    Endoscopic Dilation Balloons Recalled for Bursting and Leaking Failures

    Olympus recalled 3,354 EZDilate wire-guided dilation balloons due to failures in inflation, deflation, and retrieval, with incidents of bursting, leaking, and foreign bodies left in patients.

    Product
    EZDilate Wire Guided Balloon 11-12-13. Indicated for endoscopic dilation of strictures in the alimentary tract in adults and adolescents (>12 years). Model: BD-410X-1355
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0775-2024·2024-02-07

    FDA recalls EVair 03 compressor models for elevated formaldehyde levels

    FDA recalls EVair 03 air compressors (models 1609000, 1609002) for elevated formaldehyde when used with certain ventilators. The hazard was identified during preliminary testing under worst-case conditions: elevated room temperature (40°C) and minimal gas flow (2 L/min).

    Product
    EVair 03 (Jun-air) air compressor, model numbers: 1609000 and 1609002
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0827-2024·2024-02-07

    Custom Surgical Procedure Kits Recalled for Sterilization Assessment Failures

    American Contract Systems has recalled 2,717 custom surgical procedure kits used in neurosurgery nationwide. Components were added without proper assessment of their suitability for the sterilization process.

    Product
    Custom procedural convenience kits and trays, general hospital use, labeled as: a) IR NEURO PACK, kit number AGNE20J; b) ADULT CRANIOTOMY PACK, kit number LLCR99; c) LAMINECTOMY PACK, kit number LLLC26; d) KIT, CRANIOTOMY, kit number MMCR11J; e) KIT, NEURO SPINE, kit n
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0830-2024·2024-02-07

    Surgical kits for childbirth recalled for sterilization and functionality risks

    American Contract Systems is recalling C-section surgical kits that were sterilized without proper assessment. Components may have lost function or drug efficacy, or have excess sterilization residuals.

    Product
    Custom procedural convenience kits and trays, Obstetrical & Gynecological use, labeled as: a) C-SECTION PACK, kit number FDCS01AA; b) C-SECTION PACK, kit number FDCS01AB; c) C-SECTION STERILE PACK, kit number HGCS68J; d) C-SECTION PACK, kit number HICS50H; e) C-SECTION
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0904-2024·2024-02-07

    Knee Replacement Component Recalled for Potential Material Degradation

    Howmedica Osteonics Corp. is recalling P7 28MM 10 DEGREE +4MM INSERT knee replacement components (Lot 61311701, 62122001) due to potential oxidation in aged UHMWPE material that could affect material properties.

    Product
    P7 28MM 10 DEGREE +4MM INSERT Intended for knee replacement Part Number: 6302-6-107
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0943-2024·2024-02-07

    Olympus EZDilate Balloon Dilators Recalled for Device Malfunction and Retained Foreign Bodies

    Olympus recalled EZDilate Wire Guided Balloon endoscopic dilators due to reports of bursting, leaking, and retained foreign bodies during patient procedures. The Class II recall affects 4,182 units used to treat esophageal strictures.

    Product
    EZDilate Wire Guided Balloon 16-17-18. Indicated for endoscopic dilation of strictures in the alimentary tract in adults and adolescents (>12 years). Model: BD-410X-1855
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0954-2024·2024-02-07

    MRI Machine Coil Seal Adhesive May Create Sharp Edges

    The Intera Achieva 1.5T Pulsar MRI machine's Quadrature Body Coil seal adhesive may fail, creating sharp edges that could injure patients. All units of this model are affected.

    Product
    Intera Achieva 1.5T Pulsar. Model (REF) Number 781171.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0928-2024·2024-02-07

    Tank hose assembly recalled for incorrect material and missing perforations

    AtriCure recalls tank hose assemblies due to manufacturing defects. Certain lots have outer sheaths missing required pin perforations and inner tubes made of incorrect material.

    Product
    Packaged, Tank Hose Assembly CMA-US, Product Catalog Number A001056
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0867-2024·2024-02-07

    Aesculap Needle Holders Distributed With Incorrect Product Labels and Packaging

    Aesculap Inc. is recalling needle holder models that were distributed with incorrect product labels. The MB215R was labeled as MB362R and vice versa, which may cause procedural delays.

    Product
    MB215R - MILLS DUROGRIP TC Micro Needle Holder, straight, 8:, (203 mm), "TC MILLS NDLE HOLDRRND HNDLSTR203MM"
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0826-2024·2024-02-07

    Custom Procedural Convenience Kits Recalled for Sterilization Validation Failure

    American Contract Systems is recalling 244 custom procedural kits (Baby PICC, Pediatric PICC, and PORT PACK) distributed nationwide. Components subjected to sterilization without proper validation documentation may have reduced functionality or elevated sterilization residuals.

    Product
    Custom procedural convenience kits and trays, general hospital use, labeled as: a) Baby PICC Kit, kit number UIBP90J; b) Baby PICC Kit, kit number UIBP90K; c) PORT PACK (PS 058330), kit number UIPO82AB; d) Pediatric PICC Kit, kit number UIPP76K;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0896-2024·2024-02-07

    SCORPIO U-DOME PATELLA Knee Implants Affected by Material Oxidation Risk

    Certain SCORPIO U-DOME PATELLA knee replacement devices may experience material degradation due to aged raw material. The manufacturer is recalling affected units because material oxidation could compromise device durability and performance.

    Product
    SCORPIO U-DOME PATELLA -Intended for knee replacement Part Number: 73-3708
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0972-2024·2024-02-07

    NovoTHOR Whole Body Light Pod Gen 3.0 Canopy Strut Ball Stud May Fail

    A ball stud on the gas strut may fail on NovoTHOR Whole Body Light Pod units, potentially causing injury if the canopy malfunctions while someone is using the device.

    Product
    NovoTHOR Whole Body Light Pod, Gen 3.0 (1) Product Code S2188 - Reg (2) Product Code S2189 - Reg PRX (3) Product Code S2190 - XL
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0836-2024·2024-02-07

    Medical sterilization chemical integrators recalled due to labeling discrepancy

    TERRAGENE S.A. is recalling over 36,000 chemical integrator strips used to verify sterilization in healthcare settings because the instructions distributed with the products don't match the FDA-cleared instructions for use.

    Product
    Terragene Integron IT26-C Terragene Integron IT26-C with extender Benco Dental Chemical Integrator [5726-583] Tuttnauer (WTL198-0082) Terragene Integron (PCD26-C) Terragene Bionova PCD (PCD222-C)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0890-2024·2024-02-07

    Knee replacement implant recalled due to material oxidation risk

    Howmedica Osteonics is recalling a knee replacement patellar component that may have been manufactured with oxidized raw material. Products using UHMWPE over 5 years old can develop elevated oxidation and degraded material properties.

    Product
    SCORPIO TOTAL KNEE CONCENTRIC DOME PATELLA-SZ #11 -Intended for knee replacement Part Number: 73-2110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0922-2024·2024-02-07

    Knee replacement implant recalled for potential material oxidation risk

    Howmedica Osteonics is recalling the DUR PCA MTK REV INS RT knee replacement implant manufactured with UHMWPE material over 5 years old. The material can develop elevated oxidation levels that may degrade its properties.

    Product
    DUR PCA MTK REV INS RT Intended for knee replacement Product Number: 6728-2-711
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0872-2024·2024-02-07

    Knee replacement implant recalled for material oxidation risk

    Howmedica Osteonics is recalling SCORPIO RECESSED PATELLA knee replacement components due to potential oxidation of the UHMWPE material in units manufactured with raw material over 5 years of age.

    Product
    SCORPIO RECESSED PATELLA-Intended for knee repalcment Part Number: 3044-0032
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0953-2024·2024-02-07

    MRI Scanner Quadrature Coil Seal Failure Poses Patient Contact Risk

    Philips is recalling the Intera 1.5T Achieva Nova-Dual MRI scanner due to potential failure of the Quadrature Body Coil seal adhesive. If the seal fails, sharp edges may contact patients, risking skin injuries.

    Product
    Intera 1.5T Achieva Nova-Dual. Model (REF) Number 781173.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0921-2024·2024-02-07

    Knee replacement implant recalled due to potential material degradation

    Howmedica Osteonics recalls DUR PCA MTK REV INS RT knee replacement implants due to potential oxidation of UHMWPE material that could compromise material properties. Patients should contact their healthcare provider.

    Product
    DUR PCA MTK REV INS RT Intended for knee replacement Product Number: 6728-2-709
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0876-2024·2024-02-07

    Knee Implant Inserts Recalled Due to Potential Material Degradation

    Howmedica Osteonics is recalling SCORPIO TS TIB knee implant inserts (Part Number 72-4-0510) manufactured with UHMWPE material over 5 years old. The material may have elevated oxidation levels that could affect implant performance.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-0510
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0834-2024·2024-02-07

    Endoscopic Surgical Stapler Reload May Fail to Form Complete Staple Line

    An endoscopic surgical stapler reload may fail to properly form staples during use, potentially leaving tissue inadequately sealed. This could lead to bleeding or require additional surgery.

    Product
    ENDOPATH ECHELON 45mm RELOADS WITH GRIPPING SURFACE TECHNOLOGY (GST), ECHELON Endopath Stapler, Endoscopic Linear Cutter Reload (+Gripping Surface technology), 45MM WHITE VASCULAR/THIN, Product No. GST45W
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0883-2024·2024-02-07

    Knee replacement implant insert recalled due to material oxidation risk

    Howmedica Osteonics is recalling Scorpio-Flex knee implant inserts manufactured with over-5-year-old UHMWPE material, which may develop elevated oxidation levels that could affect material properties.

    Product
    Scorpio-Flex Ttl Kn P-S Tib Brg Insrt Asy- Intended for knee replacement Part Number: 72-15-0324
    Category
    Medical Device
    Distribution
    Distributed nationwide