The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6876–6900 of 40007

  • ModerateFDA (Devices)·Z-2156-2024·2024-06-26

    OPTETRAK One Peg Patella components recalled for out-of-specification vacuum bags

    Exactech is recalling OPTETRAK One Peg Patella knee implants due to vacuum bags packaged below specification. The recall affects units with multiple lot numbers distributed worldwide.

    Product
    OPTETRAK One Peg Patella,, Item Numbers: a) 200-03-26, 26MM; b) 200-03-29, 29MM; c) 200-03-32, 32MM; d) 200-03-35, 35MM; e) 200-03-38, 38MM; f) 200-03-41, 41MM
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1921-2024·2024-06-19

    Thoratec HeartMate System Monitor display malfunction in left ventricular assist devices

    The Thoratec HeartMate System Monitor is being recalled due to display malfunctions affecting 4,842 devices worldwide. These issues may prevent proper monitoring and device control.

    Product
    Thoratec HeartMate System Monitor, REF: 1286, L1286, 1286A, L1286A, 1286A-US, L1286A-US, 1286C, L1286C, L1386, 1286A-CAN, 1286INT and L1286INT. Left ventricular assist device
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2041-2024·2024-06-19

    MRI Systems Power Cable Terminal Block Fire Hazard Recall

    Canon Medical MRI systems are being recalled because the terminal block securing the power cable may disconnect, potentially causing electrical arcing and fire. 153 units are affected across the United States and Puerto Rico.

    Product
    MRI systems: Vantage Orian MRT-1550 (MEXL-1550), Vantage Elan MRT-2020 (MEXL-1520), Vantage Titan MRT-1504 (MEXL-1504), Vantage Titan 3T MRT-3010 (MEXL-3010), Vantage Galan 3T MRT-3020 (MEXL-3020)
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-2134-2024·2024-06-19

    Stimuplex A Nerve Needles Recalled for Mislabeled DEHP Content

    B Braun Medical Inc is recalling over 1.1 million Stimuplex A nerve block needles labeled as DEHP-free, but the adhesive contains traces of DEHP. The mislabeling poses a risk to users who selected the product specifically to avoid DEHP exposure.

    Product
    Stimuplex A, 30 DEG, 22GX2", 0.70x50mm, Catalogue Number: 4894502
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2034-2024·2024-06-19

    Streptococcal A Rapid Test Kits Recalled for Unauthorized At-Home Distribution

    Wondfo USA has recalled Streptococcal A rapid test kits that are being sold for unauthorized at-home and direct-to-consumer use. The kits should not be used outside professional healthcare settings.

    Product
    Streptococcal A rapid test kits, labeled as: Wondfo Biotech Co., Ltd, WondView Strep A Test Kit, Guangzhou Wondfo Biotech Co., Ltd, Wondfo One Step Strep A Swab Test, Dealmed Medical Supplies LLC, Strep A Rapid Test Kit, Jant Pharmacal Corporation, Accustrip VALUPAK Strep A Test
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2141-2024·2024-06-19

    Fresenius AquaA hemodialysis water purification device pressure control malfunction

    Fresenius is recalling 4 hemodialysis water purification devices for pressure control malfunctions. When concentrate pressure exceeds the 19.9 bar limit, the device stops supplying water and halts dialysis treatment.

    Product
    US AquaA 900H-Typ USA-3 x 208v-Intended for the purification of water to be used for hemodialysis Vivonic Part Numbers: G02020110 Fresenius Part Number: 24-090A-1
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2136-2024·2024-06-19

    CODMAN BACTISEAL EVD Catheter Set: Sterile packaging defect recalled

    Integra LifeSciences is recalling 135 CODMAN BACTISEAL EVD Catheter Sets due to defects in sterile packaging that may compromise product sterility.

    Product
    CODMAN BACTISEAL EVD Catheter Set - Indicated for gaining access to the ventricles of the brain and can be used with dimensionally compatible devices for draining cerebrospinal fluid (CSF) and other fluids of similar physical characteristics as a means of reducing intracranial p
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2142-2024·2024-06-19

    VITROS Immunodiagnostic Calibrators Recalled for Potential Accuracy Bias

    Ortho-Clinical Diagnostics is recalling VITROS Anti HBs Calibrators due to potential for positively biased results caused by signal reduction over shelf life. Approximately 481 units were distributed worldwide.

    Product
    VITROS Immunodiagnostic Products Anti HBs Calibrators. The VITROS Anti-HBs Calibrator Pack contains 3 X labelled Calibrator tube (1 per level: C1 - green, C2 - yellow, C3 - red).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2139-2024·2024-06-19

    Aeos Robotic Digital Microscope recalled for safety mechanism failure

    Aesculap Inc is recalling Aeos Robotic Digital Microscope models with Product Code PV010 due to failure of the integrated safety mechanism. The robotic arm may drop more than 10 cm from its original position after the emergency stop button is pressed.

    Product
    Aeos Robotic Digital Microscope, Product Code: PV010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2129-2024·2024-06-19

    OMTech Desktop Laser Engraver recalled for missing safety interlocks

    Rygel Advanced Machines recalls OMTech Desktop Laser Engravers due to missing safety interlocks and labeling. The devices lack required redundant interlocks and certification labels that prevent accidental laser exposure.

    Product
    OMTech Desktop Laser Engraver
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2138-2024·2024-06-19

    EVD Catheter Sterile Packaging Defect Recall for Intracranial Drainage

    Integra LifeSciences is recalling CODMAN BACTISEAL EVD catheters due to external packaging seal defects that may compromise sterility. The recall affects 59 units distributed internationally.

    Product
    CODMAN BACTISEAL Clear EVD Catheter 1.9mm I.D. Catheter Set- indicated for gaining access to the ventricles of the brain and can be used with dimensionally compatible devices for draining cerebrospinal fluid (CSF) and other fluids of similar physical characteristics as a means of
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2039-2024·2024-06-19

    Coviden Monoject 60ml Syringes Recalled for Inadvertent Distribution

    Coviden Monoject 60ml Luer-Lock syringes were inadvertently distributed despite being quarantined. Mckesson Medical-Surgical is recalling approximately 100 units (lot 330737X) distributed in the United States.

    Product
    Coviden Monoject 60ml Syringe Luer-Lock Tip-used to inject fluid into or withdraw fluids from the body MMS Catalog Number: 1159851 Cardinal Catalog Number: 8881560125
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2133-2024·2024-06-19

    Stimuplex A Anesthesia Needles Recalled for Undisclosed DEHP in Glue

    B Braun Medical Inc is recalling 108,811 units of Stimuplex A anesthesia needles because the devices are labeled as DEHP-free but the glue contains traces of DEHP.

    Product
    Stimuplex A, 30 DEG, 20GX6", 0.90x150mm, Catalogue Number: 4894278
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2040-2024·2024-06-19

    Cardiac SPECT System Recalled for Defective Service Handle Fastening

    GE Medical Systems is recalling MyoSPECT cardiac imaging systems due to service handles on internal lead covers that could loosen or release, potentially causing the cover to drop and injure service personnel. The recall affects 133 devices distributed worldwide.

    Product
    MyoSPECT System, Model H3912AA and H3912B, and MyoSPECT ES System, Model H3912AB and H3912BD, dedicated cardiac SPECT (single photon emission computerized tomography system).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2135-2024·2024-06-19

    CORI Surgical System Software Error Causes Tracking Array Flickering

    The CORI Starter Kit surgical system may experience display flickering from a software tracking error, potentially causing surgical delays during orthopedic procedures.

    Product
    CORI Starter Kit, Real Intelligence CORI, CORI STARTER KIT - UNIVERSAL.Intended to assist the surgeon in providing software-defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures Product Numbers: (1) ROB10000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2038-2024·2024-06-19

    EsoFLIP 30mm Balloon Dilation Catheter Recalled for Measurement Inaccuracy

    Covidien is recalling EsoFLIP 30mm balloon dilation catheters due to saline conductivity issues that may cause inaccurate esophageal measurements, potentially leading to patient harm.

    Product
    EsoFLIP, 30mm BALLOON DILATION CATHETER, REF ES-330, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2137-2024·2024-06-19

    CODMAN EVD BACTISEAL Catheter Sterile Packaging Defect Recall

    Integra LifeSciences recalls CODMAN EVD BACTISEAL catheters due to defects in sterile packaging that may compromise product sterility. The defect affects 106 units distributed worldwide.

    Product
    CODMAN EVD BACTISEAL 1.9mm I.D. Catheter Set- indicated for gaining access to the ventricles of the brain and can be used with dimensionally compatible devices for draining cerebrospinal fluid (CSF) and other fluids of similar physical characteristics as a means of reducing intra
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2033-2024·2024-06-19

    Streptococcal A Rapid Test Kits Recalled for Unauthorized Distribution

    Wondfo USA is recalling 102,500 units of IMCO Strep A Rapid Test Kits due to unauthorized distribution for at-home, over-the-counter, and direct-to-consumer use.

    Product
    Independent Medical Co-op Inc., Streptococcal A rapid test kits, labeled as: IMCO Strep A Rapid Test Strip and IMCO Strep A Rapid Test, Part Number STP25-IMC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2131-2024·2024-06-19

    Stimuplex A Injection Needles Recalled for DEHP Mislabeling

    B Braun Medical Inc is recalling Stimuplex A injection needles because the devices are labeled as DEHP-free, but the glue used contains traces of DEHP. The recall affects 20,850 units distributed in the US and Canada.

    Product
    Stimuplex A, 30 DEG, 24GX1", 0.55x25mm, Catalogue Number: 4894251.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2031-2024·2024-06-19

    Streptococcal A Rapid Test Kits Recalled for Unauthorized Distribution

    Wondfo USA has recalled 170,000 units of Clarity Strep A Rapid Test kits due to unauthorized distribution for at-home use, non-prescription use, over-the-counter use, and direct-to-consumer sales. The recall affects test kits distributed nationwide.

    Product
    Clarity and Clarity Diagnostics LLC, Streptococcal A rapid test kits, Labeled as: a) Clarity Strep A Rapid Test, Part Number CD-STP25, b) Clarity Diagnostics LLC, Clarity Strep A Rapid Test, Part Number CD-STP25V
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2037-2024·2024-06-19

    NEOMED Oral Syringes Recalled Over Missing Expiration Dates on Labels

    Avanos Medical is recalling NEOMED oral syringes because expiration dates were not printed on outer shipping labels, allowing expired units to reach customers.

    Product
    NEOMED* Pharmacy Syringes - Nonsterile (Non ENFit) with below product descriptions: a.0.5mL Oral Syringe Orange NonSterile, Product Code BC-S05EO; b. 12mL Oral Syringe Orange NonSterile, Product Code BC-S12EO; c. 1mL Oral Syringe Orange NonSterile, Product Code BC-S1EO;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2132-2024·2024-06-19

    Medical device nerve block needles incorrectly labeled as DEHP-free

    Stimuplex A nerve block needles labeled as DEHP-free contain trace amounts of DEHP in the adhesive. B Braun is recalling approximately 1.78 million units distributed in the US and Canada.

    Product
    Stimuplex A, 30 DEG, 21GX4", 0.80x100mm, Catalogue Number: 4894260
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2143-2024·2024-06-19

    Darby Dental Prophylaxis Paste Mislabeled with Incorrect Part Number

    Young Dental Manufacturing is recalling 534 units of Darby Prophylaxis Paste with 1.23% Fluoride Ion (Lot 248607) due to incorrect part number labeling. The product was labeled as part number 045032 instead of the correct 040032.

    Product
    Darby Prophylaxis Paste with 1.23% Fluoride Ion, Mint Coarse
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2032-2024·2024-06-19

    Streptococcal A Rapid Test Kits Recalled for Unauthorized At-Home Distribution

    Wondfo USA recalls Areta Strep A test kits (Lot E03920802) distributed for unauthorized at-home and over-the-counter use. The recall affects 75,000 units distributed nationwide.

    Product
    Streptococcal A rapid test kits, labeled as: Easy Healthcare Corporation, Areta Strep A Swab Test and EASY at Home Medical LLC, Areta One Step Strep A Swab Test, Part Number ARST-100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2035-2024·2024-06-19

    NEOMED Pharmacy Syringes recalled due to missing expiration dates

    Avanos Medical is recalling NEOMED Pharmacy Syringes because expiration dates were not printed on the outer shipping labels. Approximately 37,476 cases of various syringe sizes were distributed worldwide.

    Product
    NEOMED* Pharmacy Syringes - Nonsterile (Non ENFit) with below product descriptions: a. 0.5mL Oral Syringe Amber NonSterile, Product Code BA-S05EO; b. 12mL Oral Syringe Amber NonSterile, Product Code BA-S12EO; c. 1mL Oral Syringe Amber NonSterile, Product Code BA-S1EO; d
    Category
    Medical Device
    Distribution
    Distributed nationwide