The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6851–6875 of 40007

  • HighFDA (Devices)·Z-2201-2024·2024-07-03

    Medtronic MIRRO MRI implantable defibrillator recalled for weld defect

    Medtronic is recalling 3 MIRRO MRI DR SureScan implantable cardioverter defibrillators due to a manufacturing weld crack that caused devices to fail quality checks. The defect was detected during manufacturing before devices reached patients.

    Product
    MIRRO MRI DR SureScan, Model Number DDME3D1, Implantable Cardioverter Defibrillator
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2211-2024·2024-07-03

    Medtronic ICD Implants Recalled for Manufacturing Weld Crack Defects

    Medtronic recalls 9 units of CROME VR MRI SureScan implantable cardioverter defibrillators due to a manufacturing weld crack that caused devices to fail quality control leak testing.

    Product
    CROME VR MRI SureScan, Model Number DVPC3D1, Implantable Cardioverter Defibrillator
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2219-2024·2024-07-03

    Stryker Hoffman LRF Wire Tensioner Adjustment Ring May Become Loose

    Stryker is recalling 39 Hoffman LRF Wire Tensioner devices because the adjustment ring may loosen, preventing proper tension setting. No injuries reported.

    Product
    Stryker Hoffman LRF Wire Tensioner REF 4933-9-100, a component of the Hoffmann LRF System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2223-2024·2024-07-03

    Cook Drainage Catheter Recall: Incorrect Expiration Date Labels

    Cook Incorporated is recalling 15 units of a multipurpose drainage catheter due to product labels stating incorrect expiration dates that extend beyond the devices' true expiration, creating a risk of expired device use.

    Product
    Ultrathane Cook-Cope Type Locking Loop Multipurpose Drainage Catheter-ULT12.0-38-45-P-6S-CLM-RH-ntended for percutaneous drainage in a variety of drainage applications (e.g., nephrostomy, biliary and abscess), either by direct stick or Seldinger access technique ORDER NUMBER: GP
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-2178-2024·2024-07-03

    Sonic Scaler Tip Holder May Be Oversized, Preventing Proper Seating

    The tip holder portion of Titan Blis-Sonic Scaler tips may be oversized, preventing proper seating in the scaler handpiece. This defect could result in the tip becoming loose during use.

    Product
    Titan Blis-Sonic Scaler packaged with the Titan Scaler Tip - Perio (part number 261669) (1) P/N 264563 (2) P/N 264565 The scaler tip is used with an air drive scaler for subgingival scaling and fine access. The Perio tip is used for lingual supragingival scaling of mandibu
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2220-2024·2024-07-03

    CDC Influenza H5 Subtyping Kit may produce inconclusive test results

    The CDC Influenza A/H5 Subtyping Kit's H5b component may fail to amplify, resulting in inconclusive results. 191 units were distributed nationwide.

    Product
    CDC, Influenza A/H5 Subtyping Kit, Model/Catalog Number: FluIVD03-11
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2130-2024·2024-06-26

    Ventilator Operator's Guide Recalled for Missing Critical MRI Safety Information

    ZOLL is recalling operator's guides for the ZOLL 731 Ventilator because they omit critical MRI safety information. Missing distance guidance could cause the ventilator to malfunction during MRI procedures.

    Product
    ZOLL 731 Ventilator (EMV+, AEV, Eagle II) - for MRI Compatible Devices - Operator's Guide and Quick Reference Guide (QRGs) as follows: Part Numbers: 1. 799-EGL2-02 2. 799-EGL2-02-01 3. 799-EGL2-02-04 4. 799-EGL2-02-05 5. 799-EGL2-02-08 6. 799-EGL2-02-10 7. 799-EGL2-02-
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2020-2024·2024-06-26

    Ventilator HAMILTON-C6 may fail to restart, risking oxygen deprivation

    Hamilton Medical AG is recalling the HAMILTON-C6 ventilator due to a sensor failure that may prevent re-initiation after reconnection, potentially causing hypoxia.

    Product
    Ventilator HAMILTON-C6, PN: 160021
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2158-2024·2024-06-26

    Exactech OPTETRAK Knee Implants Recalled for Out-of-Specification Vacuum Bag Packaging

    Exactech is recalling OPTETRAK Advanced Patella knee implant components packaged in vacuum bags that did not meet manufacturing specifications. Improper packaging could compromise product sterility.

    Product
    OPTETRAK, Advanced Patella, 3 Peg Implant, Item Numbers: a) 200-07-26, 26MM; b) 200-07-29, 29MM; c) 200-07-32, 32MM; d) 200-07-35, 35MM; e) 200-07-38, 38MM
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2150-2024·2024-06-26

    TabloCart power cord connector may overheat in hemodialysis system

    Outset Medical is recalling 431 TabloCart hemodialysis system carts due to power cord connector defects that may cause overheating, sparks, and smoke, potentially delaying treatment or causing burns.

    Product
    TabloCart with Prefiltration Drawer PN-0006813, with power cords: PN-0005746 (10-foot), PN-0006578 (15-foot), PN-0005747 (20-foot)10-, 15- and 20-foot cords respectively), used with the Tablo Hemodialysis System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2149-2024·2024-06-26

    Ethicon MONOCRYL Plus Sutures Recalled for Packaging Defect

    Ethicon recalled 287,892 MONOCRYL Plus Antibacterial Sutures worldwide due to a packaging machine defect that created holes in primary packaging, potentially compromising sterility and risking infection.

    Product
    MONOCRYL Plus Antibacterial (poliglecaprone 25) Suture - Intended for use in general soft tissue approximation and/or ligation where an absorbable material is indicated. PRODUCT CODE: MCP266H13 MCP3200H16 MCP3212H16 MCP3213H16 MCP340H13 MCP345H13 MCP416H14 MCP417H14 M
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2144-2024·2024-06-26

    VICRYL Sutures recalled due to packaging defect compromising sterility

    Ethicon recalls 341,532 units of VICRYL surgical sutures worldwide due to holes in primary packaging that compromise sterility and could result in infection.

    Product
    VICRYL (polyglactin 910) Suture - Indicated for use in general soft tissue approximation and/or ligation, including use in ophthalmic surgery, but not for use in cardiovascular and neurological tissues. PRODUCT CODE: J214H J218H J258H J268H J269H J327H J344H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2146-2024·2024-06-26

    PDS II Polydioxanone Sutures Recalled Due to Compromised Sterility

    Ethicon is recalling 56,952 units of PDS II polydioxanone sutures distributed worldwide because a packaging defect resulted in compromised sterility, which could lead to infection. No illnesses have been reported.

    Product
    PDS II (polydioxanone) Suture - Intended for use in general soft tissue approximation, including use in paediatric cardiovascular tissue, in microsurgery and in ophthalmic surgery. These sutures are particularly useful where the combination of an absorbable suture and extended wo
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2161-2024·2024-06-26

    Xstar Safety Slit Knife Recalled for Incorrect Blade Bevel Orientation

    Beaver Visitec International is recalling the Xstar Safety Slit Knife Model 378227 because some units have the blade bevel installed incorrectly—facing downward instead of the intended upward orientation.

    Product
    Xstar Safety Slit Knife, 2.75 mm 45¿ Bevel Up, Model Number 378227
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2154-2024·2024-06-26

    Bard Foley Catheter Trays Recalled for Temperature Display Malfunction

    C.R. Bard Inc is recalling 6,420 Foley catheter trays nationwide because some devices may not display temperature readings or may display erratic readings. The malfunction could affect patient monitoring.

    Product
    Bard Medical SureStep Foley Tray System, 16 Fr., Catalog #A319416AM; and Bard Medical Bardex IC Complete Care Infection Control Temperature-Sensing Foley Catheter Tray with Bard Hydrogel and Bacti-Guard Silver Alloy Coating, 350 ml Urine Meter, 16 Fr, Catalog #319416AM. Intended
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2157-2024·2024-06-26

    OPTETRAK Inset Patella knee implants recalled for improper vacuum packaging

    Exactech is recalling OPTETRAK Inset Patella knee implants packaged in out-of-specification vacuum bags that may compromise product integrity during storage or sterilization.

    Product
    OPTETRAK Inset Patella, Item Numbers: a) 200-05-23, 23MM; b) 200-05-26, 26MM; c) 200-05-29, 29MM
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2151-2024·2024-06-26

    Hospital bed mattress covers may delaminate from improper cleaning

    Baxter Healthcare is recalling Centrella Max and Pro+ hospital bed mattresses that may develop delaminated top covers when cleaned with bleach-containing solutions. The mattresses prevent and treat pressure injuries.

    Product
    Centrella Max - The Centrella Smart+ Bed is intended for use in healthcare environments as a patient support system to prevent and/or treat pressure injuries.Multiple model numbers of Centrella Max mattresses and pro+ mattresses. (1) Centrella Max Surface, REF P7922A01; (2) C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2155-2024·2024-06-26

    Exactech Knee Patella Components Recalled Due to Out-of-Specification Vacuum Bags

    Exactech is recalling OPTETRAK Three Peg Patella knee components packaged in out-of-specification vacuum bags. The affected products were distributed worldwide.

    Product
    OPTETRAK Three Peg Patella, Item Numbers: a) 200-02-26, 26MM; b) 200-02-29, 29MM; c) 200-02-32, 32MM; d) 200-02-35, 35MM; e) 200-02-38, 38MM; f) 200-02-41, 41MM;
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2160-2024·2024-06-26

    NxStage PureFlow-B Hemodialysis Solution Bags Recalled Due to Bursting Chambers and Caustic Fluid

    NxStage PureFlow-B hemodialysis solution bags may burst during preparation, releasing caustic electrolyte fluid that can cause chemical burns. Affected units are distributed nationwide.

    Product
    NxStage PureFlow-B Solution, Premixed Dialysate for Hemodialysis, Device Catalog Numbers RFP-400, RFP-401, RFP-402, RFP-403, RFP-404, RFP-405, RFP-406, RFP-453, RFP-454, RFP-456
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2153-2024·2024-06-26

    Howmedica Gray Revision Instrument Tray Recalled for Design Enabling Instrument Reuse

    Howmedica is recalling the Gray Revision Instrument System Accessory Tray/Case due to a design flaw that may enable reuse and re-sterilization of single-use, sterile-packaged instruments.

    Product
    Gray Revision Instrument System Accessory Tray/Case, Catalog/Part Number: 6210-9-910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2152-2024·2024-06-26

    Storage Case Design Flaw May Allow Reuse of Single-Use Surgical Instruments

    Howmedica Osteonics Corp. is recalling HRIS Storage & Sterilization Cases (Part 6210-9-900) due to a design flaw that may allow reuse and resterilization of single-use, sterile instruments. This poses a contamination and infection risk.

    Product
    HRIS Storage & Sterilization Case and Tray, Catalog/Part Number: 6210-9-900
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2145-2024·2024-06-26

    FDA Recalls VICRYL Plus Antibacterial Sutures Due to Packaging Defect

    Ethicon is recalling VICRYL Plus Antibacterial Sutures due to a packaging machine defect that created holes in the primary packaging, potentially compromising product sterility. Affected sutures may pose an infection risk.

    Product
    VICRYL Plus Antibacterial (polyglactin 910) Suture - Indicated for use in general soft tissue approximation and/or ligation, except for ophthalmic, cardiovascular and neurological tissues. PRODUCT CODE: VCP196H VCP417H VCP602H VCP603H VCP662H VCPB259H VCPB94
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2148-2024·2024-06-26

    MONOCRYL Surgical Sutures Recalled for Packaging Sterility Defect

    Ethicon recalls 306,000 MONOCRYL surgical sutures worldwide due to holes in primary packaging from a manufacturing defect that compromises sterility and could result in infection.

    Product
    MONOCRYL (poliglecaprone 25) Suture - Intended for use in general soft tissue approximation and/or ligation where an absorbable material is indicated PRODUCT CODE: Y315H Y345H Y359H Y398H Y416H Y417H Y426H Y427H Y935H Y936H Y945H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2147-2024·2024-06-26

    PDS Plus Antibacterial Surgical Sutures Recalled for Compromised Sterility

    Ethicon recalls PDS Plus Antibacterial sutures due to packaging defects that compromised sterility. The affected units may cause infection if used in surgery.

    Product
    PDS Plus Antibacterial (polydioxanone) Suture - Intended for use in general soft tissue approximation, including use in paediatric cardiovascular tissue, in microsurgery and in ophthalmic surgery. These sutures are particularly useful where the combination of an absorbable suture
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2162-2024·2024-06-26

    Xstar Safety Slit Knife Recalled for Incorrect Blade Configuration

    Beaver Visitec International is recalling 126 Xstar Safety Slit Knives with incorrect blade configuration. The recalled knives have the bevel oriented to the back instead of the front.

    Product
    Xstar Safety Slit Knife, 2.75 mm 45¿ Bevel Up, Model Number 378227, a component of CustomEye Kits, Numbers 584562, 5800109
    Category
    Medical Device
    Distribution
    Distributed nationwide