The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6476–6500 of 40007

  • ModerateFDA (Devices)·Z-2580-2024·2024-08-21

    VITROS Folate Reagent Pack Recalled for Delayed Test Results

    Ortho-Clinical Diagnostics is recalling VITROS Folate Reagent Pack due to fibrinogen precipitation causing delayed test results. The recall affects 18,467 units distributed worldwide.

    Product
    VITROS Immunodiagnostic VITROS Folate Reagent Pack 1/2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2622-2024·2024-08-21

    Salivary Testosterone ELISA Quality Control Failure Invalidates Test Results

    DRG International is recalling Salivary Testosterone ELISA kits (Model SLV-3013) due to out-of-range quality controls that invalidate test runs and delay patient results. The recall affects 257 units distributed nationwide in six states.

    Product
    Product Name: Salivary Testosterone ELISA Model/Catalog Number: SLV-3013 Product Description: An enzyme immunoassay for the quantitative in vitro diagnostic measurement of free active testosterone in saliva.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2545-2024·2024-08-21

    Discrete Chemistry Analyzer Recalled Due to Carousel Malfunction

    Beckman Coulter is recalling 59 units of its Access 2 Immunoassay System Analyzer due to misaligned index wheels causing carousel motion errors that disable the analyzer and cancel patient tests.

    Product
    Discrete photometric chemistry analyzer for clinical use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2446-2024·2024-08-14

    Puritan Bennett 500 Series Ventilators recalled due to volatile organic compound release

    Covidien recalls 34,642 Puritan Bennett 500 Series Ventilators due to release of volatile organic compound (2-propanol, 1,3-dichloro) from gas pathway components during prolonged use beyond 10 years.

    Product
    Puritan Bennett 500 Series Ventilators (Description/REF): PURITAN BENNETT 560 VENTILATOR/4096600, PURITAN BENNETT PB560 VENTILATOR EU-DIV/4096600-01, PURITAN BENNETT 560 VENTILATOR JAPAN/4096600-02, PURITAN BENNETT 560 VENTILATOR APAC/4096600-03, Puritan Bennett 560 Ventilat
    Category
    Medical Device
    Distribution
    34 states
  • CriticalFDA (Devices)·Z-2442-2024·2024-08-14

    Medline Medical Procedure Kits Recalled Due to Defective Plastic Syringes

    Medline is recalling over 1.6 million medical procedure kits nationwide and internationally due to plastic syringe defects. The affected kits contain syringes with leaks, breakage, and quality issues that may pose risks to patient health.

    Product
    Medline procedure kits labeled as: 1) CONTINUOUS BLOCK, Pack Number DYNJRA0960C; 2) COMBINED SPINAL AND EPIDURAL, Pack Number DYNJRA1268C; 3) WAL- UNIVERSAL BLOCK TRAY, Pack Number DYNJRA1638C; 4) BASIC DIAGNOSTIC TRAY, Pack Number DYNJRA1928; 5) PREOP NERVE BLOCK TRAY
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2444-2024·2024-08-14

    Medline Procedure Kits Recalled Due to Defective Syringes and Quality Issues

    Medline procedure kits containing defective plastic syringes have been recalled due to leaks, breakage, and quality issues that may harm patients. The recall affects over 1.6 million units distributed worldwide.

    Product
    Medline procedure kits labeled as: 1) WMC HYBRID OR PACK PART 1 , Pack Number CMPJ08068F ; 2) VASCULAR PACK , Pack Number CMPJ11455B ; 3) SALEM CATH LAB-LF , Pack Number DYNJ26938J ; 4) EH PEDIATRIC CATH , Pack Number DYNJ49920L ; 5) ARTERIOGRAM PACK, Pack Number DYNJ5
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2419-2024·2024-08-14

    CADD-Solis Ambulatory Infusion Pumps with Software Defects Affecting Device Responsiveness

    CADD-Solis Model 2100 infusion pumps with pre-v4.3 software have defects affecting occlusion detection and device responsiveness. Manufacturer recommends updating to software version 4.3 (2023) to resolve the issues.

    Product
    CADD-Solis Ambulatory Infusion Pumps, Model 2100. Intended for the following uses: Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site, epidural space or subarachnoid space. Therapies that re
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2420-2024·2024-08-14

    CADD-Solis VIP Ambulatory Infusion Pump Class I Recall

    Smiths Medical is recalling CADD-Solis VIP Model 2110 infusion pumps in a Class I action affecting units worldwide.

    Product
    CADD-Solis VIP ambulatory Infusion Pumps, Model 2110. Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site, epidural space or subarachnoid space. Therapies that require a continuous rate of in
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2443-2024·2024-08-14

    Medline Procedure Kits Recalled Due to Defective Plastic Syringes

    Medline procedure kits containing defective plastic syringes are being recalled nationwide. The syringes may leak, break, or have other quality issues that could pose a risk to patient health.

    Product
    Medline procedure kits labeled as: 1) NEPHROLOGY PACK, Pack Number DYNJ59089; 2) NERVE BLOCK TRAY, Pack Number DYNJRA1221A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2421-2024·2024-08-14

    Smiths Medical CADD-Solis VIP Ambulatory Infusion Pumps Recalled Worldwide

    Smiths Medical is recalling CADD-Solis VIP ambulatory infusion pumps (models 21-2120, 21-2125, 21-2127) worldwide. The FDA has classified this as a Class I recall.

    Product
    CADD-Solis VIP ambulatory Infusion Pumps, Model 2120 (21-2120, 21-2125, and 21-2127) Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site, epidural space or subarachnoid space. Therapies t
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2497-2024·2024-08-14

    BD PYXIS MEDBANK Medication Cabinet Software Issue Causes Incorrect Bin Labels

    CareFusion is recalling BD PYXIS MEDBANK medication dispensing cabinets due to a software issue that causes incorrect bin information to print on restock labels, potentially leading to medication selection errors.

    Product
    BD PYXIS MEDBANK TWR MN CR-6HH-1FH-3FM-P, REF: 169-92 containing software version 3.9.1.9
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2475-2024·2024-08-14

    GE SIGNA MR355 MRI System Recalled for Potential Implant Overheating Risk

    GE SIGNA MR355 MRI systems running software versions SV25.5 or SV25.6 may cause implant overheating in certain scanning conditions. Risk occurs when using specific imaging sequences with the Optimized T2 FLAIR feature disabled.

    Product
    SIGNA MR355, with affected software versions: SV25.5, SV25.6; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2515-2024·2024-08-14

    Centurion Procedure Kits with Defective Syringes Recalled Worldwide

    Medline Industries is recalling Centurion procedure kits due to defective plastic syringes affected by an FDA safety alert. The syringes may leak or break and pose a potential risk to patient health.

    Product
    Centurion procedure kits labeled as NEURO ANGIO PACK, Pack Number DYNDA1431A
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2471-2024·2024-08-14

    GE SIGNA 1.5T MR Systems May Overheat Implants in Low SAR Mode

    GE Medical Systems recalled 2,146 SIGNA 1.5T MR systems that may overheat implants during certain imaging sequences in Low SAR mode due to a software defect in radiofrequency safety calculations.

    Product
    1.5T SIGNA HDxt Family, with affected software versions: HD16.0_V03 to HD16.4, HD23.0_V03, HD28.0, HD29.1, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2496-2024·2024-08-14

    Automated Medication Dispensing Cabinet Software Issue with Incorrect Bin Labeling

    BD PYXIS MEDBANK automated medication dispensing cabinets with software version 3.9.1.9 may generate incorrect bin location labels during restocking. This could cause medications to be placed in wrong storage locations.

    Product
    BD PYXIS MEDBANK TWR MN CR-4HH-5FM-P, REF: 169-91 containing software version 3.9.1.9
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2513-2024·2024-08-14

    Surgical Staple Reinforcement Devices Recalled for Incorrect Expiration Dating

    W.L. Gore & Associates recalled 51 units of GORE SEAMGUARD Bioabsorbable Staple Line Reinforcement due to incorrect expiration date labeling. The devices were labeled with a four-year and ten-day expiration date instead of the validated two-year shelf life.

    Product
    GORE SEAMGUARD Bioabsorbable Staple Line Reinforcement Configured for Circular Staplers, 25mm; Catalog number: 1BSGC25;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2509-2024·2024-08-14

    Philips IntelliVue Patient Monitors with disabled monitoring software options

    Philips IntelliVue Patient Monitors (MX400/450/500/550) with software versions L.x or M.x lack required monitoring capabilities due to removed software entitlements. The missing features could lead to incorrect or delayed patient treatment.

    Product
    IntelliVue Patient Monitor MX450 with L.x and M.x; K.x provided with L.x entitlements Model Number: 866062. Indicated for use by health care professionals for monitoring and recording of, and to generate alarms for, multiple physiological parameters of adults, pediatrics, an
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2470-2024·2024-08-14

    GE SIGNA Voyager MRI systems risk implant overheating under specific configurations

    GE SIGNA Voyager MRI systems may exceed prescribed radiofrequency limits under specific operating conditions, risking overheating of MR conditional implants. The issue occurs with certain imaging sequences when the Optimized T2 FLAIR option is disabled.

    Product
    SIGNA Voyager, with affected software versions: PX26.0 to PX26.6, VX28.0, VX29.1, VX29.2, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2498-2024·2024-08-14

    Automated Dispensing Cabinet Software Error May Print Incorrect Medication Bin Labels

    CareFusion's BD PYXIS MEDBANK automated dispensing cabinet contains a software flaw that may print incorrect medication bin labels, potentially leading to dispensing of wrong medications.

    Product
    BD PYXIS MEDBANK TWR MN CR-6HH-2FH-2FM-P, REF: 169-93 containing software version 3.9.1.9
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2532-2024·2024-08-14

    FDA Recalls CryoPatch Cardiac Tissue Grafts Due to Invalid Test Results

    Artivion has recalled CryoPatch SG cardiac tissue patches used in pulmonary surgeries due to approval and release with invalid test results. Patients who received implants should consult their healthcare provider.

    Product
    (1) CryoPatch SG Pulmonary Human Cardiac Hemi-Artery - Artery Patch, SGPH00 Cryopreserved Decellularized Cardiac Tissue Allograft Prepared with SynerGraft (SG) Technology; and (2) CryoPatch SG Pulmonary Human Cardiac Branch Patch, SGP020, Cryopreserved Decellularized Cardiac Tis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2516-2024·2024-08-14

    Medline Centurion Procedure Kits Recalled for Syringe Leaks, Breakage, and Quality Defects

    Medline has recalled Centurion procedure kits containing syringes affected by an FDA safety alert. The syringes may leak, break, or have other quality defects, posing a risk to patient health.

    Product
    Centurion procedure kits labeled as: 1) CVC INSERT BUNDLE 16CM, Pack Number ECVC3260; 2) CVC DOUBLE LUMEN 16CM, Pack Number ECVC8105
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2477-2024·2024-08-14

    GE Brivo MR355 MRI System Software Issue Causing Implant Overheating Risk

    GE HealthCare has recalled certain Brivo MR355 MRI systems due to a software issue that can cause overheating of implanted medical devices in specific imaging scenarios. Approximately 375 units have been affected worldwide.

    Product
    Brivo MR355, with affected software versions: SV20.3, SV23.3, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2511-2024·2024-08-14

    Philips IntelliVue Patient Monitors Shipped with Missing Monitoring Capabilities

    Philips IntelliVue patient monitors shipped or updated with software that removes monitoring capabilities, potentially delaying or resulting in incorrect treatment.

    Product
    IntelliVue Patient Monitor MX550 with L.x and M.x; K.x provided with L.x entitlements Model Number: 866066. Indicated for use by health care professionals for monitoring and recording of, and to generate alarms for, multiple physiological parameters of adults, pediatrics, and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2493-2024·2024-08-14

    Medication dispensing cabinet software issue causes incorrect medication bin labels

    A software issue in BD PYXIS MEDBANK automated medication dispensing cabinets can cause incorrect medication bin labels on restock labels, potentially leading to medication storage errors.

    Product
    BD PYXIS MEDBANK TWR MN CR-2HH-6FH, REF: 169-88 containing software version 3.9.1.9
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2491-2024·2024-08-14

    BD PYXIS MEDBANK Cabinet Software Causes Incorrect Medication Labels

    FDA recall of BD PYXIS MEDBANK automated medication dispensing cabinets due to a software defect that prints incorrect bin information on restock labels, potentially leading to medication identification errors.

    Product
    BD PYXIS MEDBANK TWR MN CR-12HH-1FM-P, REF: 169-85 containing software version 3.9.1.9
    Category
    Medical Device
    Distribution
    Distributed nationwide