The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6051–6075 of 27393

  • HighFDA (Devices)·Z-1143-2024·2024-02-28

    Ionolux dental cement recalled for manufacturing defect affecting curing

    Ionolux dental cement capsules may contain incorrect plungers that prevent proper curing. Affected batches distributed in the US and internationally should not be used.

    Product
    Ionolux, Catalog (REF) Numbers: a) 2115, b)2117, c) 2118, d) 2119, e) 2120, f) 2122; dental cement
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1172-2024·2024-02-28

    Synapse CV 6 Imaging Software Calculation Error May Cause Misdiagnosis

    FUJIFILM Synapse CV 6 medical imaging software may incorrectly calculate left ventricle mass measurements. If used for diagnosis, this calculation error could lead to patient misdiagnosis and incorrect treatment, potentially causing long-term health consequences.

    Product
    Synapse CV 6. with AR. A web-based application as the primary user interface for the processing of medical images.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1170-2024·2024-02-28

    3M Surgical Clipper Blade Assembly Recalled Due to Burn Risk

    3M recalled 764,580 Specialty Blade Assemblies for surgical clippers due to risk of burns from overheating. The blade can reach temperatures exceeding 77°C if left running improperly.

    Product
    3M Specialty Blade Assembly, REF 9660,70-2011-8491-1, 7100213026, used with used with 3M Surgical Clipper Catalog Number 9661L
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1173-2024·2024-02-28

    OPTIMIZER CCM X11 Implantable Pulse Generator May Fail to Deliver Therapy

    The OPTIMIZER model CCM X11 implantable pulse generator may incorrectly detect a charging error and cease delivering cardiac therapy, potentially causing patients to experience heart failure symptoms. A total of 1,469 units are affected.

    Product
    OPTIMIZER model CCM X11 implantable pulse generator (IPG) devices - Smart Mini and Lite
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1169-2024·2024-02-28

    3M Surgical Blade Assembly Recalled for Burn Injury Risk During Use

    3M is recalling the Specialty Blade Assembly (REF 9660) used with 3M Surgical Clippers worldwide due to burn risk if the blade overheats during operation. Approximately 52.8 million units affected across all lot codes.

    Product
    3M Specialty Blade Assembly, REF 9660,70-2011-8462-2, 7100213114, used with used with 3M Surgical Clipper Catalog Number 9661L
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1167-2024·2024-02-28

    ESG Cutting Forceps Jaw May Fracture During Use or Inspection

    Olympus Corporation of the Americas is recalling ESG PK Cutting Forceps because the jaw may fracture during pre-procedure inspection or during the procedure, posing a potential injury risk.

    Product
    ESG PK CUTTING FORCEPS, 5MM, 33CM
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1154-2024·2024-02-28

    X-Ray C-Arm System Internal Board Defect Causes Abnormal Images

    Canon Medical System X-ray C-arm systems may display abnormal images due to an internal board manufacturing defect, potentially preventing exam completion and requiring patients to be re-examined with alternative equipment.

    Product
    The device is an X-ray system that is capable of radiographic and fluoroscopic studies and is used in an interventional setting. The system consists of a C-arm which is equipped with an X-ray tube, beam limiter and X-ray receptor, X-ray controller, computers with system and proce
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1146-2024·2024-02-28

    Henry Schein Criterion Level 3 Earloop Masks Recalled for Non-Validated Equipment

    AMD Medicom Inc. is recalling Henry Schein Criterion Level 3 Earloop Masks because they were produced on non-validated equipment not included in the initial product qualification.

    Product
    HENRY SCHEIN¿ CRITERION¿ EARLOOP MASKS LEVEL 3 (BLUE) (item code 570-2448)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1144-2024·2024-02-28

    Philips Allura Xper Interventional X-ray System Display and Imaging Malfunction

    A framegrabber card malfunction in Philips Allura Xper interventional X-ray systems may cause display failures, preventing proper visualization of medical images and delaying procedures.

    Product
    Philips Allura Xper Interventional Fluoroscopic X-ray Systems, specifically the Disk Bay of the PC component of affected systems. Affected PCs: FlexVision PC Allura Xper Model Name - Model Number: Allura Xper FD10 722003 722010 722026; Allura Xper FD10/10 722005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1155-2024·2024-02-28

    X-ray fluoroscopy system may display abnormal images due to detector board defect

    Canon Medical's INFX-8000F X-ray system may display abnormal horizontal stripe patterns due to a manufacturing change in the flat panel detector's internal board, potentially preventing exam completion.

    Product
    The INFX-8000F is designed to take advantage of the latest technological innovations to reduce dose and to save time. A revolutionary graphic user interface and a multi-tasking computer enable the system to fully meet the requirement for optimum image quality, safety, ease of use
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1151-2024·2024-02-28

    Philips Allura Xper X-ray systems disk bay component may malfunction

    Philips has recalled certain Allura Xper interventional X-ray systems because the disk bay component may fail, potentially preventing system operation and imaging procedures.

    Product
    Philips Allura Xper Interventional Fluoroscopic X-ray Systems, specifically the Disk Bay of the PC component of affected systems. Affected PCs: Imaging Processing PC, Host PC, FlexVision PC Allura Xper Model Name - Model Number: Allura Xper FD10 722003 722010 722026;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1147-2024·2024-02-28

    Henry Schein Criterion Anti-Fog Earloop Masks Recalled for Equipment Validation Issue

    AMD Medicom Inc. is recalling Henry Schein Criterion Anti-Fog Earloop Masks Level 3 (Blue) because the masks were produced on non-validated equipment not included in the product qualification process.

    Product
    HENRY SCHEIN¿ CRITERION¿ ANTI-FOG EARLOOP MASKS LEVEL 3 (BLUE) (item code 570-3281)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1145-2024·2024-02-28

    Philips Azurion Interventional X-ray Systems framegrabber card may fail to display images

    The framegrabber card in Philips Azurion interventional X-ray systems may fail to display diagnostic images properly, potentially delaying procedures.

    Product
    Philips Azurion Interventional Fluoroscopic X-ray Systems, specifically the Disk Bay of the PC component of the affected system. Affected PCs: FlexViewing PC Azurion Model Name - Model Number: Azurion 7 B12 722067; Azurion 7 B20 722068; Azurion 7 M12 722078 722223;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1179-2024·2024-02-28

    Biliary Endoprosthesis Labeling Mismatch Risks Incorrect Device Placement

    W.L. Gore's GORE VIABIL Short Wire Biliary Endoprosthesis may be mislabeled regarding drainage holes, risking extended procedures, infections, and unplanned device removal in 24 units distributed in Georgia.

    Product
    GORE VIABIL Short Wire Biliary Endoprosthesis, Product labeled as (1) Catalog Number VSWVH1008, 10 mm x 8 cm; with holes; and (2) Catalog Number VSWVN1008, 10 mm x 8 cm; no holes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1177-2024·2024-02-28

    Azurion 5 X-Ray System Generator May Fail Due to Circuit Short

    Philips Azurion 5 X-ray systems with Certeray generators may experience power loss due to a potential short circuit in the power inverter board, potentially delaying or interrupting medical procedures.

    Product
    Azurion 5 with a Certeray generator-To perform image guidance in diagnostic, interventional, and minimally invasive surgery procedures Models: (1) 722227 (2) 722228
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1178-2024·2024-02-28

    Azurion 7 Medical Imaging System May Lose Power During Procedures

    Philips Azurion 7 imaging systems may experience power loss due to a potential short circuit in the power inverter, risking delays or termination of diagnostic and surgical procedures.

    Product
    Azurion 7 with a Certeray generator-To perform image guidance in diagnostic, interventional, and minimally invasive surgery procedures Models: (1) 722223, (2) 722224, (3) 722225, (4) 722226
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1175-2024·2024-02-28

    Automated Impella Controller Software Update Resolves Pump Recognition Issue

    Abiomed is releasing software Version 8.5 for the Automated Impella Controller to fix an issue in versions 8.4 and 8.4.1 where the device failed to recognize the pump. Approximately 4,463 units were distributed nationwide.

    Product
    Automated Impella Controller (AIC), Product No. 0042-0000-US, 0042-0010-US, 0042-0040-US. Used with Impella Ventricular Support Systems (cardiovascular)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1171-2024·2024-02-28

    Cardiology imaging software may calculate heart chamber size incorrectly

    Synapse Cardiology PACS software versions 7.0–7.3.0 may calculate left ventricle mass incorrectly, potentially leading to misdiagnosis or wrong treatment plans. Thirteen units have been distributed in the US and Israel.

    Product
    Synapse Cardiology PACS V7.3.0, V7.2, V7.1, V7.0. A web-based application as the primary user interface for the processing of medical images.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1181-2024·2024-02-28

    Radiation Oncology Treatment Planning Software VERIQA Calculation Error

    PTW-FREIBURG's VERIQA software (versions 2.0 and 2.1) may incorrectly calculate gamma passing rates when users exclude voxels below a dose threshold, potentially displaying false positive dose evaluation results.

    Product
    Software VERIQA (S070031), version 2.0 and 2.1- Software package for display, evaluation and digital processing of medical image data sets and treatment plans in radiation oncology.
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0962-2024·2024-02-21

    GE Healthcare Lullaby Incubator bedside panels may fail to latch properly

    GE Healthcare Lullaby Incubator bedside panels and portholes may appear closed but not be properly latched. If impacted, these panels can disengage and fall open, creating a fall risk for patients.

    Product
    GE Healthcare Lullaby Incubator Model Hood Door FRU kit, Part Numbers: M1169767, M1160674, M1187512, M1206646, M1166822
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0980-2024·2024-02-21

    Impella Cardiac Support Catheters: Risk of Left Ventricle Perforation

    Impella cardiac catheters are being recalled due to risk of left ventricle perforation during operator use. The FDA has classified this Class I recall affecting 91,914 units worldwide.

    Product
    Impella catheters - Intravascular micro axial blood pumps that support a patient's circulatory system. (1) Product Code 005042 - Impella 2.5 (2) Product Code 005062 - Impella 5.0 (3) Product Code 005082- Impella LD (7) Product Codes 0550-0008 and 1000100 - Impella 5.5 wit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0959-2024·2024-02-21

    GE Healthcare Care Plus Incubator Hood Latching Defect Increases Fall Risk

    GE Healthcare incubator hoods can appear closed but may not be properly latched, posing a fall risk if patients impact an unsecured panel.

    Product
    GE Healthcare Care Plus Hood Field Replacement Unit (FRU) kit, Part Numbers: 6600-0047-851, 6600-0033-850, 6600-0081-850, 6600-0961-500, 6600-0083-850
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0961-2024·2024-02-21

    GE Healthcare Incubators Bedside Panel Latch Failure Poses Fall Risk

    GE Healthcare incubators have defective bedside panels that may appear closed but not be properly latched, creating a patient fall risk when the panels disengage upon impact.

    Product
    GE Healthcare Lullaby Incubator Model Hood FRU kit, Part Numbers: M1169566, M1160659, M1206259, M1206260, M1166836, M1166814
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0957-2024·2024-02-21

    GE Healthcare neonatal incubator bedside panels may fail to latch properly

    GE Healthcare is recalling neonatal incubators because the bedside panel can appear closed while unlatched. Impact could cause it to fall open, risking patient injury.

    Product
    GE Healthcare neonatal incubator, models: a) Care Plus, b) Care Plus 1000, c) Care Plus 2000, d) Care Plus 3000, e) Care Plus 4000, Plus 4000
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0960-2024·2024-02-21

    GE Healthcare incubator bedside panel may disengage and fall open

    The bedside panel on GE Healthcare Care Plus incubators may appear closed while unlatched. If impacted, the panel can fall open, exposing patients to injury risk.

    Product
    GE Healthcare Care Plus Hood Door FRU kit, Part Numbers: 6600-0082-850, 6600-0504-800, 6600-0148-800, and 6600-0970-500
    Category
    Medical Device
    Distribution
    0 states