The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

401–425 of 5100

  • CriticalFDA (Devices)·Z-0188-2026·2025-11-05

    Distal access catheters recalled after coating material lifting inside the lumen

    Balt USA is recalling 207 MEGA Ballast Distal Access Platform catheters over a manufacturing defect in which coating material lifts within the catheter's distal lumen. The FDA has classified it Class I.

    Product
    Brand Name: MEGA Ballast Distal Access Platform Product Name: Mega Ballast Model/Catalog Number: MEGABT09180, MEGABT09190, MEGABT091100, MEGABT091110 Software Version: N/A Product Description: The Mega Ballast 091 is designed with a semi-rigid proximal shaft and a highly flex
    Category
    Medical Device
    Distribution
    12 states
  • CriticalFDA (Devices)·Z-0163-2026·2025-11-05

    MRI operating suites recalled over ice blockage in the magnet venting system

    IMRIS is recalling the IMRIS iMRI 3T V Operating Suite because an ice blockage in the Siemens 3 Tesla magnet's venting system could rupture the helium containment system during a quench. The FDA classified it Class I.

    Product
    IMRIS Operating Suite, IMRIS iMRI 3T V, containing Siemens 3 Tesla MRI Magnet, vIDA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0318-2026·2025-11-05

    Glucose monitoring app recalled because it can terminate and miss alerts

    Dexcom is recalling version 1.15.0 of the G6 and G6 Pro Android CGM app because a software defect can terminate the app, stopping glucose values, alarms and alerts. The FDA classified it Class I.

    Product
    Brand Name: Dexcom G6 Continuous Glucose Monitoring System Product Name: Dexcom G6 and G6 Pro Android US CGM App Model/Catalog Number: SW11678 Software Version: version 1.15.0 Product Description: Dexcom G6 and G6 Pro Android US CGM App SW11678 version 1.15.0 Component: Dexc
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0136-2026·2025-10-29

    Impella controllers recalled over purge pressure issues from retainer failures

    Abiomed is recalling Automated Impella Controllers over the potential for purge pressure issues caused by purge retainer failures, covering 9,177 distributed units.

    Product
    Automated Impella Controller (AIC) labeled as the following with corresponding Product Codes: 1. AIC w/Impella Connect for ECP, Product Code: 1000432. 2. Dbl optical, AIC Impella Connect, Phg US, Product Code: 1000201. 3. Impella Controller, Packaged, AU, Product Code: 0042-00
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0070-2026·2025-10-29

    Hemodialysis bloodline sets recalled over micro air bubbles from damaged connectors

    B. Braun is recalling Streamline Bloodline Sets for Dialog because damaged arterial and venous patient connectors may cause micro-air bubbles in the bloodline and air-in-line alarms.

    Product
    Brand Name: Hemodialysis Bloodlines Product Name: STREAMLINE BLOODLINE SET FOR DIALOG Model/Catalog Number: SL-2010M2096 Software Version: N/A Product Description: STREAMLINE BLOODLINE SET FOR DIALOG Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0154-2026·2025-10-29

    IV burette sets recalled over missing internal shutoff valve component

    ICU Medical is recalling 23,203 IV administration sets because the burette component is missing an internal shutoff valve intended to stop fluid flow.

    Product
    IV Administration sets. 23" (58 cm) 150 mL Burette Set (Clave, Shut Off) w/Clave, Luer Lock, REF: B33359; 23" (58 cm) 150 ml Burette Set (w/Shut Off), MicroClave, Clamp, REF: B9213; 70" (178 cm) 150 ml Burette Set (Clave, Shut-Off) w/3-Way Stopcock, Clave, Graduated Adapter,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0057-2026·2025-10-22

    BF-P190 bronchovideoscopes recalled for clarified laser and coagulation instructions

    Olympus is recalling EVIS EXERA III Bronchovideoscope BF-P190 units for instructions-for-use updates on safe use with laser, argon plasma coagulation and high-frequency therapy equipment.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-P190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0112-2026·2025-10-22

    Curve F-J ablation catheters recalled after tip detachment during unpacking

    Abbott is recalling 11,810 TactiFlex Sensor Enabled Ablation Catheters in the F-J curve after becoming aware of tip detachment events during removal from the packaging.

    Product
    TactiFlex Sensor Enabled Ablation Catheter, 8F, 115 cm, FJ, (BiD Curve F-J), REF A-TFSE-FJ; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0109-2026·2025-10-22

    UniD curve ablation catheters recalled after tip detachment from packaging

    Abbott is recalling 407 TactiFlex Sensor Enabled Ablation Catheters in the UniD curve D configuration after becoming aware of tip detachment events during removal from the packaging.

    Product
    TactiFlex Sensor Enabled Ablation Catheter, 8F, 115 cm, D, (UniD Curve D), REF A-TFSE-D; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0079-2026·2025-10-22

    ACCOLADE single chamber standard life pacemakers recalled for software update

    Boston Scientific is recalling 16,077 ACCOLADE SR SL pacemakers, part of a software update designed to prevent Safety Mode starting outside hospital because of a high battery impedance state.

    Product
    ACCOLADE SR SL (Model L300)
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0084-2026·2025-10-22

    ACCOLADE dual chamber extended life MRI pacemakers recalled for software update

    Boston Scientific is recalling 34,180 ACCOLADE DR EL MRI pacemakers, part of a software update designed to prevent Safety Mode starting outside hospital because of a high battery impedance state.

    Product
    ACCOLADE DR EL MRI (Model L331)
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0082-2026·2025-10-22

    ACCOLADE dual chamber MRI pacemakers recalled for Safety Mode software update

    Boston Scientific is recalling 90,931 ACCOLADE DR SL MRI pacemakers, part of a software update designed to prevent Safety Mode starting outside hospital because of a high battery impedance state.

    Product
    ACCOLADE DR SL MRI (Model L311)
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0091-2026·2025-10-22

    PROPONENT dual chamber extended life MRI pacemakers recalled for software update

    Boston Scientific is recalling 63,851 PROPONENT DR EL MRI pacemakers, part of a software update designed to prevent Safety Mode starting outside hospital because of a high battery impedance state.

    Product
    Model Number L231, PROPONENT DR EL MRI Pacemaker
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0043-2026·2025-10-22

    Thoracic endovascular grafts recalled over coating scrapings that may embolize

    Cook Medical is recalling 695 Zenith Alpha 2 Thoracic Endovascular Grafts because affected devices may contain PTFE coating scrapings that could be released during deployment.

    Product
    Zenith Alpha 2 Thoracic Endovascular Graft, Catalog Prefix ZTA2- Reference Part Numbers ZTA2-P-40-117-W ZTA2-P-40-167 ZTA2-P-40-167-W ZTA2-P-40-217-W ZTA2-P-42-121 ZTA2-P-42-121-W ZTA2-P-42-173 ZTA2-P-42-173-W ZTA2-P-42-225 ZTA2-P-42-225-W ZTA2-P-44-125 ZTA2-P-44-1
    Category
    Medical Device
    Distribution
    31 states
  • CriticalFDA (Devices)·Z-0063-2026·2025-10-22

    BF-Q190 bronchovideoscopes recalled for clarified laser and coagulation instructions

    Olympus is recalling EVIS EXERA III Bronchovideoscope BF-Q190 units for instructions-for-use updates on safe use with laser, argon plasma coagulation and high-frequency therapy equipment.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-Q190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0067-2026·2025-10-22

    BF-XT40 bronchofiberscopes recalled for updated therapy equipment use instructions

    Olympus is recalling OES Bronchofiberscope BF Type XT40 units for instructions-for-use updates on safe use with laser, argon plasma coagulation and high-frequency therapy equipment.

    Product
    OES BRONCHOFIBERSCOPE OLYMPUS BF TYPE XT40
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0094-2026·2025-10-22

    ESSENTIO single chamber MRI pacemakers recalled for Safety Mode software update

    Boston Scientific is recalling 61,700 ESSENTIO SR SL MRI pacemakers, part of a software update designed to prevent Safety Mode starting outside hospital because of a high battery impedance state.

    Product
    Model Number L110, ESSENTIO SR SL MRI Pacemaker
    Category
    Medical Device
    Distribution
    0 states