The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3701–3725 of 27375

  • HighFDA (Devices)·Z-0547-2025·2024-12-04

    Philips ST SENSE Breast Coil Recalled for Potential Patient Safety Risk

    Philips is recalling 5,231 ST SENSE Breast Coils nationwide due to a potential safety issue that could harm patients during MRI scanning. Affected units are identified by specific serial numbers.

    Product
    ST SENSE Breast Coil
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0517-2025·2024-12-04

    Discovery MR750w MRI Scanner Recalled for Elevated Acoustic Noise

    GE Medical Systems is recalling 8 Discovery MR750w 3.0T MRI scanners because their gradient coils can produce elevated acoustic noise during scanning under specific conditions.

    Product
    Discovery MR750w 3.0T, whole body magnetic resonance scanner
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0545-2025·2024-12-04

    Philips SENSE Breast Coil Recall for Potential Patient Safety Hazard

    Philips is recalling 5,231 SENSE Breast Coils due to a potential patient safety hazard during scan preparation and performance. The FDA has not disclosed specific details about the nature of the risk.

    Product
    SENSE Breast Coil
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0541-2025·2024-12-04

    Mammotrak Diagnostic Coil 1.5T Recalled Due to Patient Safety Concern

    Philips is recalling 5,231 Mammotrak Diagnostic Coil 1.5T units nationwide because of a potential patient safety issue during MRI scans. The FDA has classified this as a Class II recall.

    Product
    Mammotrak Diagnostic Coil 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0535-2025·2024-12-04

    VITROS Chemistry CRP Diagnostic Slides May Underreport Elevated Results

    Ortho-Clinical Diagnostics is recalling 7,717 units of VITROS CRP diagnostic slides that may produce falsely low results for high C-reactive protein samples, risking missed diagnosis of infection or inflammation.

    Product
    VITROS Chemistry Products CRP Slides- In vitro diagnostic quantitatively measures C-reactive protein (CRP) concentration in serum and plasma Model/Catalog Number: 1926740
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0504-2025·2024-12-04

    Defibtech Adult Defibrillation Pads Recalled for Labeling Error Risk

    Defibtech is recalling 22,294 DDP-2001 Adult Defibrillation Pads distributed in Ireland. Some pads had unauthorized labels applied, which could allow expired pads to appear current, and dried hydrogel may reduce electrical delivery during use.

    Product
    Defibtech DDP-2001: Adult Defibrillation Pads For use with AED Models: Lifeline View Auto, lifeline Pro, lifeline ECG, lifeline View (DDU-2XXX Series). -Indicated for use on victims of sudden cardiac arrest (SCA.)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0548-2025·2024-12-04

    Philips ST SENSE Breast Imaging Coil Recalled for Patient Safety Risk

    Philips is recalling 5,231 units of the ST SENSE Breast Dx Coil nationwide due to a potential safety issue that may harm patients during breast imaging scans. No injuries have been reported.

    Product
    ST SENSE Breast Dx Coil
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0502-2025·2024-12-04

    Defibtech Defibrillation Pads Mislabeled, Creating Risk of Expired Pads in Use

    Defibtech DDP-100 defibrillation pads distributed in Ireland had authorized labels replaced with unauthorized ones, making expired pads appear fresh. Dried hydrogel on expired pads may fail to deliver adequate energy for cardiac resuscitation.

    Product
    Defibtech DDP-100 Adult Defibrillation Pads For use with AED Models: Lifeline and Lifeline Auto (DDU-1:XX Series)- Indicated for use on victims of sudden cardiac arrest (SCA)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0553-2025·2024-12-04

    Shimadzu Autosampler Water Intrusion May Cause Electrical Short Circuit

    Shimadzu laboratory autosamplers are being recalled due to water intrusion from a dehumidifier that can cause electrical short circuits. Affected units are distributed worldwide, including across the United States.

    Product
    Autosampler, Models: SIL-20ACXR CL, SIL-20ACHT CL, SIL-30AC CL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0527-2025·2024-12-04

    Smiths Medical Tracheal Tube Introducer Recall Due to Inadequate Disinfection

    Smiths Medical is recalling reusable tracheal tube introducers due to potential fluid ingress during reprocessing and concerns about the adequacy of recommended disinfectants.

    Product
    smiths medical portex Venn Reusable Tracheal Tube Introducer, 15Ch x 60cm, REF 14-504-17 and REF 14-504-17JP
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0559-2025·2024-12-04

    Baxter MiniCap Peritoneal Dialysis Transfer Set Connector Separation Recall

    Baxter is recalling MiniCap Extended Life PD Transfer Sets (Part Number 5C4482) due to reports of the female connector separating from the main body. Approximately 409,464 units are affected worldwide.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number 5C4482; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0516-2025·2024-12-04

    RENASYS EDGE Pump Recall Due to Battery Charging Failure Risk

    Smith & Nephew recalls 1,589 RENASYS EDGE wound therapy pumps due to battery charging failure if not properly maintained. Affected patients may experience treatment interruption.

    Product
    RENASYS EDGE The RENASYS¿ EDGE pump is indicated for patients who would benefit from a suction pump (NPWT), as it may promote wound healing via removal of fluids, including irrigation fluids and body fluids, wound exudate and infectious materials.
    Category
    Medical Device
    Distribution
    13 states
  • HighFDA (Devices)·Z-0509-2025·2024-12-04

    MEDLINE Epidural and Spinal Anesthesia Procedure Kits: Connector Insertion Issue

    Multiple MEDLINE procedure kits used for epidural and spinal anesthesia have connectors that may not open fully, preventing proper catheter insertion during medical procedures.

    Product
    MEDLINE procedure kits labeled as follows: 1) COMBINED SPINAL AND EPIDURAL, REF DYNJRA1268B; 2) COMBINED SPINAL AND EPIDURAL, REF DYNJRA1268C; 3) FEMORAL BLOCK TRAY, REF DYNJRA1739A; 4) FEMORAL BLOCK TRAY, REF DYNJRA1739B; 5) 18G CPNB 20G STYLETED CATHETER, REF DYNJRA1
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0580-2025·2024-12-04

    MICRO-X Rover Mobile X-ray System environmental operating requirements

    Micro-X Ltd. is recalling 6 units of the MICRO-X Rover Mobile X-ray System due to environmental operating risks. The system requires strict temperature, humidity, and altitude controls to prevent capacitor malfunction, overheating, and unintended start-up.

    Product
    MICRO-X Rover Mobile X-ray System, # MXU-RV35
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-0512-2025·2024-12-04

    MEDLINE Procedure Kits: Connectors May Prevent Intended Catheter Insertion

    MEDLINE procedure kits are being recalled because connectors may not allow proper catheter insertion if not fully opened. The recall affects 3006 units distributed in the US and internationally.

    Product
    MEDLINE procedure kits labeled as follows: 1) PERIPHERAL CONTINUOUS NERVE BL, REF PAIN1423A; 2) CONT. 20G EPI MRI COMPATIBLE, REF PAIN1470A; 3) EPIDURAL CATHETERIZATION KIT, REF PAIN1644
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0563-2025·2024-12-04

    Baxter Peritoneal Dialysis Transfer Set Connector Separation Recall

    Baxter is recalling 83,448 units of MiniCap Extended Life PD Transfer Sets due to reports of female connector separation from the device body.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number R5C4482; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0526-2025·2024-12-04

    Karl Storz surgical instruments recalled for sterility barrier defect

    Karl Storz Endoscopy has recalled 105 surgical instruments with holes in their sterility barriers. The defect may compromise product sterility; affected devices were distributed nationwide and internationally.

    Product
    4.5 x 180 mm REF 28208BKS Aggressive Cutter, sterile, 6x 3.5 x 70 mm REF 28206CBS Full Radius Resector, sterile, 6x 5.5 x 120 mm REF 28205NDS Aggr. Pro Line Shaver Blade, sterile, 6x 5.5 x 120 mm REF 20205FDS Round Burr, sterile, 6x 6.5 x 120 mm REF 28205HES, Aggressi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0536-2025·2024-12-04

    Philips Achieva TX Interventional Coil 3.0T Recalled for Patient Safety Risk

    Philips recalls the Achieva TX Interventional Coil 3.0T (5,231 units) for a potential safety issue that may harm patients during MRI scan preparation or procedures.

    Product
    Achieva TX Interventional Coil 3.0T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0382-2025·2024-11-27

    Baxter Peritoneal Dialysis Transfer Sets Recalled for Chemical Exposure

    Baxter Healthcare Corporation is recalling 1,240 units of MiniCap Extended Life PD Transfer Sets (Part Number T5C4484) due to potential exposure to polychlorinated biphenyls and related compounds when used in peritoneal dialysis treatments.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp EX Short, Part Number T5C4484; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0375-2025·2024-11-27

    Baxter peritoneal dialysis transfer set recalled for PCB exposure risk

    Baxter MiniCap Extended Life PD Transfer Sets (Part 5C4482S) are being recalled due to potential exposure to polychlorinated biphenyls (PCBs). The FDA Class I recall affects 151,020 units distributed worldwide.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number 5C4482S; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0378-2025·2024-11-27

    Baxter MiniCap Peritoneal Dialysis Transfer Set recalled for potential PCB exposure

    Baxter Healthcare is recalling 58,680 units of its MiniCap Extended Life PD Transfer Set due to potential exposure to polychlorinated biphenyls (PCBs). Users should stop using affected units and consult their healthcare provider.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number R5C4482E; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0379-2025·2024-11-27

    Baxter MiniCap Dialysis Transfer Sets Recalled for PCB Exposure Risk

    Baxter is recalling MiniCap Extended Life PD Transfer Sets used in peritoneal dialysis due to potential exposure to polychlorinated biphenyls (PCBs). About 62,394 units distributed worldwide may be affected.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number R5C4483; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0373-2025·2024-11-27

    Peritoneal Dialysis Transfer Set Recalled for PCB Contamination Risk

    Baxter Healthcare recalls peritoneal dialysis transfer sets (Part Number 5C4482) due to potential contamination with polychlorinated biphenyls (PCBs). The recall affects 2.7 million units distributed worldwide.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number 5C4482; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0482-2025·2024-11-27

    Medical Device Recall: Counterfeit Batteries in Plum Infusion Systems

    Counterfeit CSB batteries are being used in Plum Infusion Systems. These unauthorized batteries fail to hold their charge and have not been tested for use with the pumps.

    Product
    Allegedly counterfeit batteries manufactured by CSB batteries being used with Plum Infusion Systems: Plum 360" Infusion System, Pump List Number 30010; Plum A+ & Plum A+3" Infusion Systems, Pump List Numbers: 11005, 11971, 12391, 12618, 20678, 20679, 20792, 60529, 12348, 1197
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0377-2025·2024-11-27

    Baxter Peritoneal Dialysis Transfer Set Recalled for PCB Contamination Risk

    Baxter Healthcare is recalling the MiniCap Extended Life PD Transfer Set due to potential exposure to polychlorinated biphenyls (PCBs). Approximately 410,862 units are affected.

    Product
    Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number R5C4482; use in Peritoneal Dialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide