The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3601–3625 of 27375

  • HighFDA (Devices)·Z-0666-2025·2024-12-18

    MICRO-X Rover Medical X-ray System Hand Switch Activation Issue

    Micro-X Ltd. is recalling 23 MICRO-X Rover Mobile X-ray Systems because the hand switch may be accidentally activated when dropped, causing the system to become unresponsive during patient imaging.

    Product
    MICRO-X Rover Mobile X-ray System, # MXU-RV19
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0663-2025·2024-12-18

    ReNew Microscissor Tip Disposable Recalled Due to Heat Shrink Failure

    Microline Surgical is recalling ReNew Microscissor Tip (Disposable) lot 00172110 due to a 2% failure rate where the heat shrink breaks off.

    Product
    Microscissor Tip (Disposable); Microline Catalog #: 3122.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0605-2025·2024-12-11

    GE Healthcare Revolution Ascend CT System Recalled for Image Rotation

    GE Healthcare Revolution Ascend CT systems can produce progressively rotated images during helical, cine, and cardiac scans. Images after the first may be rotated up to 56 degrees, potentially affecting diagnostic accuracy.

    Product
    GE Healthcare Revolution Ascend, Model number 6969000-100; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0584-2025·2024-12-11

    BD EpiCenter Medical Device Software Service Credentials Accessed by Unauthorized Party

    BD EpiCenter software service credentials were accessed by an unauthorized actor. Until credentials are updated, there is risk of unauthorized access to the software and associated data.

    Product
    BD EpiCenter Single User Software Version or Model: 441007 Catalog Number: 441007
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0619-2025·2024-12-11

    Medline MaxOrb Extra Alginate Wound Dressing Recalled for Packaging Defect

    Advanced Medical Solutions is recalling 1,800 boxes of Medline MaxOrb Extra Alginate Wound Dressing due to defects in the primary packaging pouch that compromise sterile barrier integrity. Products affected were distributed in Illinois, Texas, and Virginia.

    Product
    MEDLINE MAXORB EXTRA ALGINATE WOUND DRESSING 4X4 SQUARE REF MSC7044EP MEDLINE MOXORB EXTRA ALBINATE WOUND DRESSING 4X8 RECTANLE REF MSC7048EP Wound dressing indicated for moderate to heavily exuding chronic and acute wounds, and to control minor bleeding in superficial wounds
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0577-2025·2024-12-11

    Fluoroscopic X-ray System Hand Switch May Fail and Cause Unintended Radiation

    The Ziehm Vision R fluoroscopic x-ray system has a hand switch that may fail under mechanical stress and cause unintended radiation. Ziehm Imaging, Inc. is recalling 5 affected units distributed in the U.S.

    Product
    Ziehm Vision R. Iterventional fluoroscopic x-ray system
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0600-2025·2024-12-11

    GE Healthcare CT Systems May Display Rotated Images in Diagnostic Scans

    Certain GE Healthcare CT systems may produce progressively rotated images during diagnostic scans. If undetected and a rescan is needed, the same rotation recurs.

    Product
    GE Healthcare Discovery RT, Model Number 2374681-17, X-ray/computed tomography systems labeled as:
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0574-2025·2024-12-11

    X-ray system hand switch may fail under mechanical stress

    The Ziehm Solo FD interventional fluoroscopic x-ray system's hand switch may fail when exposed to mechanical stress, potentially causing unintended radiation. Twenty-five units are affected in the U.S. and Puerto Rico.

    Product
    Ziehm Solo FD. Interventional fluoroscopic x-ray system
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0576-2025·2024-12-11

    Fluoroscopic X-Ray System Hand Switch May Cause Unintended Radiation

    Orthoscan Inc. is recalling 22 Ziehm Vision FD fluoroscopic x-ray systems. The hand switch may fail when dropped or impacted, potentially initiating unintended radiation exposure.

    Product
    Ziehm Vision FD. Interventional fluoroscopic x-ray system
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0618-2025·2024-12-11

    McKesson Calcium Alginate Wound Dressing Recalled for Sterile Barrier Defect

    McKesson Calcium Alginate Dressing Model 3562 is recalled because defects in the primary packaging pouch compromise the sterile barrier. Lot number W00070426 affects approximately 8,000 boxes distributed across Illinois, Texas, and Virginia.

    Product
    McKesson Calcium Alginate Dressing MFR# 3562 Wound dressing indicated for moderate to heavily exuding chronic and acute wounds, and to control minor bleeding in superficial wounds.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0629-2025·2024-12-11

    MEDLINE Surgical Convenience Kits Recalled for Defective Smoke Evacuation Pencil Component

    MEDLINE is recalling 102 varieties of surgical convenience kits containing SafeAir Smoke Evacuation Pencils that have been recalled by manufacturer Stryker. The nationwide recall affects 24,754 units.

    Product
    MEDLINE convenience kits labeled as: 1) ZALE HEAD & NECK CDS, REF CDS983184I; 2) ENT MINOR, REF CDS983466L; 3) EAR, REF CDS983486K; 4) HEAD AND NECK, REF CDS984259N; 5) HEAD AND NECK, REF CDS984259O; 6) HEAD & NECK CDS, REF CDS984282L; 7) T & A, REF CDS984895I; 8) T & A,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0643-2025·2024-12-11

    MEDLINE Surgical Convenience Kits Recalled for Defective Smoke Evacuation Component

    MEDLINE is recalling surgical convenience kits nationwide because they contain smoke evacuation pencil components from a Stryker product that was previously recalled. The affected kits are used in robotic and laparoscopic surgical procedures.

    Product
    MEDLINE convenience kits labeled as: 1) GYN LAPAROSCOPY-LF, REF CDS760059I; 2) GYN LAPAROSCOPY CDS #34-RF, REF CDS920099S; 3) GYN MAJOR, REF CDS980998L; 4) ROBOTIC PROCEDURE, REF CDS982128P; 5) ROBOTIC, REF CDS984262N; 6) GYN LAPAROSCOPY, REF CDS984900M; 7) GYN LAP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0631-2025·2024-12-11

    Medline Convenience Kits Recalled Due to Defective Component

    Medline Industries is recalling 70 convenience kits containing SafeAir Smoke Evacuation Pencil components that were subsequently recalled by Stryker. The affected product types are General Endoscopy Pack and Endo Bladder Pack.

    Product
    MEDLINE convenience kits labeled as: 1) GENERAL ENDOSCOPY PACK, REF DYNJ44673G; 2) ENDO BLADDER PACK, REF DYNJ49672L
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0573-2025·2024-12-11

    Mobile C-arm hand switch defect may cause unintended X-ray emission

    Ziehm Solo Digital Mobile C-arm devices may have hand switch defects that can cause unintended radiation emission when exposed to impacts or drops. The recalled units have been distributed in the U.S. and Puerto Rico.

    Product
    Ziehm Solo. Digital Mobile C-arm
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0630-2025·2024-12-11

    Medline Surgical Kits Recalled Due to Defective Smoke Evacuation Component

    Medline is recalling 167,074 surgical convenience kits nationwide containing SafeAir Smoke Evacuation Pencils previously recalled by manufacturer Stryker for use in various surgical procedures.

    Product
    MEDLINE convenience kits labeled as: 2) ABDOMINAL LAPAROSCOPY, REF CDS760057K; 3) ABDOMINAL LAPAROSCOPY, REF CDS760057L; 4) MAJOR LAPAROTOMY CDS, REF CDS860015W; 5) MINOR LAPAROTOMY CDS, REF CDS860016P; 6) MINOR LAPAROTOMY CDS, REF CDS860016Q; 7) MINOR LAPAROTOMY CDS, REF
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0639-2025·2024-12-11

    Medline Convenience Kits Recalled Due to Defective Smoke Evacuation Component

    Medline is recalling L&D convenience kits distributed nationwide because they were manufactured with smoke evacuation pencils that Stryker subsequently recalled. The affected kits contain components from lot 23HMI048.

    Product
    MEDLINE convenience kits labeled as: L&D MINOR PACK, REF DYNJ82672
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0632-2025·2024-12-11

    MEDLINE Port Insertion Pack Recalled for Defective Component

    Medline is recalling 44 PORT INSERTION PACK kits nationwide. These kits contain SafeAir Smoke Evacuation Pencil components that were previously recalled by Stryker.

    Product
    MEDLINE convenience kits labeled as: PORT INSERTION PACK, REF DYNJ81597
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0628-2025·2024-12-11

    MEDLINE dental and oral surgery kits recalled due to defective component

    MEDLINE is recalling four types of dental and oral surgery convenience kits that were manufactured using SafeAir Smoke Evacuation Pencils, which were previously recalled by Stryker.

    Product
    MEDLINE convenience kits labeled as: 1) ORAL SURGERY PK RFID, REF DYNJ52404I; 2) ORL PACK, REF DYNJ59073B; 3) ORAL MAXILOFACIAL PK, REF DYNJ80226A; 4) DENTAL MINOR PACK, REF DYNJ83140
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0613-2025·2024-12-11

    GE Healthcare CT Operator Console Images May Rotate During Scans

    GE Healthcare CT systems may produce progressively rotated images during helical, cine, and cardiac scans. Images can rotate up to 56 degrees, potentially requiring patient rescans.

    Product
    GE Healthcare Operator Console Upgrade Types, FRU Spare Parts Number B79632DA: EU: RT Refresh Package, Non-EU: Discovery RT, Optima CT580, or Discovery CT590 RT; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0622-2025·2024-12-11

    Medline Tracheostomy Convenience Kits Recalled Due to Defective Component

    Medline is recalling 88 units of tracheostomy convenience kits containing a defective smoke evacuation pencil component that was previously recalled by Stryker. Products were distributed nationwide.

    Product
    MEDLINE convenience kits labeled as: 1) TRACH TOTE, REF DYNJ85691; 2) TRACHEOSTOMY, REF DYNJ902123J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0617-2025·2024-12-11

    Hollister CalciCare Calcium Alginate Dressing Recalled for Packaging Defect

    Advanced Medical Solutions is recalling Hollister CalciCare Calcium Alginate Dressing (Model 529937R, Lot W00070134) due to defects in the primary packaging pouch that compromise sterile barrier integrity. The affected dressing was distributed nationwide to IL, TX, and VA.

    Product
    Hollister CalciCare Calcium Alginate Dressing REF 529937R calcium alginate dressings are indicated for moderate to heavily exuding chronic and acute wounds such as: ¿ pressure ulcers ¿ leg ulcers ¿ cavity wounds ¿ lacerations ¿ post-operative surgical wounds
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0627-2025·2024-12-11

    Medline Medical Device Kits Recalled Due to Defective SafeAir Component

    Medline is recalling 980 units of medical convenience kits manufactured using SafeAir Smoke Evacuation Pencil components that Stryker previously recalled. The kits were distributed nationwide.

    Product
    MEDLINE convenience kits labeled as: 1) BREAST BIOPSY PACK-LF, REF DYNJ0160598C; 2) BREAST BIOPSY PACK-LF, REF DYNJ0842590G; 3) TREATMENT ROOM PACK, REF DYNJ41473G; 4) TREATMENT ROOM PACK, REF DYNJ41473I; 5) BREAST BIOPSY PACK, REF DYNJ44148G; 6) PRX BREAST PACK, RE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0597-2025·2024-12-11

    Siemens Atellica CI Analyzer may produce falsely elevated electrolyte test results

    Siemens' Atellica CI Analyzer may display incorrect diluent volume levels, causing falsely elevated sodium, potassium, and chloride test results in 559 units distributed worldwide.

    Product
    Atellica CI Analyzer. Catalog Numbers: 10947347.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0638-2025·2024-12-11

    MEDLINE medical convenience kits recalled for defective component

    Medline is recalling medical convenience kits (CLEAN CLOSING PACK and CLEAN CLOSURE PACK GREEN) distributed nationwide because they contain a SafeAir Smoke Evacuation Pencil component that was recalled by Stryker.

    Product
    MEDLINE convenience kits labeled as: 1) CLEAN CLOSING PACK, REF DYNJ80686A; 2) CLEAN CLOSURE PACK GREEN, REF DYNJ84667
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0583-2025·2024-12-11

    Spectral CT Devices Pose Collision and Misdiagnosis Software Risks

    Philips Spectral CT and Spectral CT Plus devices may fail to update plan positioning during interventional procedures, creating collision risks to operators and patients. A software defect may also assign incorrect patient IDs, potentially causing misdiagnosis.

    Product
    Spectral CT and Spectral CT Plus. Model Numbers: 728333, 728340, 728344.
    Category
    Medical Device
    Distribution
    Distributed nationwide