The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

8951–8975 of 11823

  • SevereFDA (Drugs)·D-1175-2015·2015-07-08

    Lincare Recalls Fluorouracil IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Fluorouracil 1200mg IV bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Fluorouracil 1200mg / D5W 274mL, Qty: 1 274 mL Bag, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1191-2015·2015-07-08

    Lincare Recalls Vancomycin HCl Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Vancomycin HCl bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Vancomycin HCl, Vancomycin 1500mg / D5W 265mL, Qty: 2 265 mL Bags, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1163-2015·2015-07-08

    Lincare Recalls TPN 3:1 Bags Due to Sterility Concerns

    Lincare, Inc. is recalling TPN 3:1 bags compounded in Arkansas between May 14 and May 27, 2015, because the sterility of the product is not assured.

    Product
    TPN 3:1, 1050 mL Bags, Qty: 6, Base Formula Dextrose 70%, Travasol 10%, Intralipid 20%, Sterile Water; Electrolytes KCL, K Phos, MgSO4, NaCl, Zinc Cl, Ca Gluconate; Vitamins, trace elements and medications Trace Ele.-Ped, Infuvite Pediat, Carnitor, Rx Only. Compounded by: United
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1164-2015·2015-07-08

    Lincare Recalls TPN 3:1 Bags Due to Sterility Concerns

    Lincare, Inc. is recalling TPN 3:1 bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    TPN 3:1, 1090 mL Bags, Qty: 7, Base Formula Dextrose 70%, Travasol 10%, Intralipid 20%, Water for Inj; Electrolytes K Phos, KCL, MgSO4, NaCl, Ca Gluconate, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200 501-2
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1203-2015·2015-07-08

    Lincare Recalls Fluorouracil IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Fluorouracil IV bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Fluorouracil 4250mg / D5W 285mL, Qty: 1 285 mL Bag, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1178-2015·2015-07-08

    Lincare Recalls Hydrocodone IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling specific lots of Hydromorphone HCl IV bags because the sterility of the product is not assured.

    Product
    HYDROmorphone HCl PF, HYDROMORPHONE HCL 1000mg /NS 500mL, Qty: 1 500 mL Bag, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1161-2015·2015-07-08

    Lincare Recalls TPN 3:1 Bags Due to Sterility Concerns

    Lincare, Inc. is recalling TPN 3:1 bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    TPN 3:1, 1750 mL Bags, Qty: 5, Base Formula Dextrose 70%, Travasol 10%, Intralipid 20%, Water for Inj; Electrolytes Famotidine, KCL, K Phos, Na Acetate, MgSO4, NaCl; Vitamins, trace elements and medications Multitrace-4, Multi Vitamin, Vitamin K, Rx Only. Compounded by: United M
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1197-2015·2015-07-08

    Lincare Recalls Vancomycin IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Vancomycin 1000mg IV bags compounded by United Medical IV Center in Arkansas because the sterility of the product is not assured.

    Product
    Vancomycin 1000mg / NS 100mL, Packaged in 100 mL Bags, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1195-2015·2015-07-08

    Lincare Recalls Gentamicin Syringes Due to Sterility Concerns

    Lincare, Inc. is recalling Gentamicin 14.4 mg syringes because the sterility of the product is not assured. The recall affects 2 syringes distributed in Arkansas.

    Product
    GENTAMICIN 14.4 mg / NS 30 mL SYRINGE, Packaged in 30 mL Syringes, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1170-2015·2015-07-08

    Lincare Recalls Fluorouracil IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Fluorouracil IV bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Fluorouracil 1400mg / D5W 278mL Qty: 1 278 mL Bag, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1183-2015·2015-07-08

    Lincare Recalls Deferoxamine Mesylate IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Deferoxamine Mesylate IV bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    DEFEROXAMINE MESYLATE 3gm / NS 240mL Accuflo, Packaged in 240 mL Bags, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1199-2015·2015-07-08

    Lincare Recalls Cefepime HCl IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Cefepime HCl IV bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Cefepime HCl, CEFEPIME 850 mg NS 50mL AccuFlo, Qty: 12 50 mL Bags, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1179-2015·2015-07-08

    Lincare Recalls Vancomycin HCl in Dextrose Due to Sterility Concerns

    Lincare, Inc. is recalling Vancomycin HCl in Dextrose compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Vancomycin HCl in Dextrose, VANCOMYCIN 750mg / D5W 150mL, Qty: 12 150 mL Bags, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1192-2015·2015-07-08

    Lincare Recalls Vancomycin HCl/Heparin Due to Sterility Concerns

    Lincare, Inc. is recalling Vancomycin HCl/Heparin compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Vancomycin HCl/Heparin, Vancomycin 50mcg/mL / Heparin 100u/mL, Qty: 3, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1154-2015·2015-07-08

    Lincare Recalls TPN 3:1 Bags Due to Sterility Concerns

    Lincare, Inc. is recalling TPN 3:1 bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    TPN 3:1, 2000 mL Bags, Qty: 7, Base Formula Dextrose 70%, Travasol 10%, Intralipid 20%, Sterile Water; Electrolytes K Acetate, Na Acetate, Famotidine, Ca Gluconate, MgSO4, NaCl, Zinc Cl; Vitamins, trace elements and medications Salenium, Multi Vitamin, Vitamin K, Ascorbic Acid, R
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1187-2015·2015-07-08

    Lincare Recalls Fentanyl Citrate IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Fentanyl Citrate IV bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    Fentanyl Citrate, FENTANYL 25,000 MCG / 500 ML, Qty: 1 500 mL Bag, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1171-2015·2015-07-08

    Lincare Recalls Vancomycin IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling Vancomycin IV bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    VANCOMYCIN 1.25gm / NS 250mL AccuFlo, Qty: 7 250 mL Bags, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1176-2015·2015-07-08

    Lincare Recalls Fluorouracil Bags Due to Sterility Concerns

    Lincare, Inc. is recalling specific Fluorouracil IV bags because the sterility of the product is not assured.

    Product
    FLUOROURACIL 1560MG / D5W 281ML, Qty: 1 281 mL Bag, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1202-2015·2015-07-08

    Lincare Recalls Hydromorphone IV Bags Due to Sterility Concerns

    Lincare, Inc. is recalling specific lots of compounded Hydromorphone HCl IV bags because the sterility of the product is not assured.

    Product
    HYDROmorphone HCl PF, Hydromorphone 1000 mg / NS 500 mL, Qty: 1 500 mL Bag, Rx Only. Compounded by: United Medical IV Center (Little Rock) 1527 South Bowman Rd. Ste. D Little Rock, AR 72211-4200.
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1156-2015·2015-07-08

    Lincare Recalls TPN 3:1 Bags Due to Sterility Concerns

    Lincare, Inc. is recalling TPN 3:1 bags compounded by United Medical IV Center because the sterility of the product is not assured.

    Product
    TPN 3:1, 997 ml without lipids Bags, Qty: 3, Base Formula Dextrose 70%, Travasol 10%, Water for Inj; Electrolytes K Acetate, Na Acetate, KCL, Na Phos, Ca Gluconate, MgSO4, NaCl, Zinc Cl; Vitamins, trace elements and medications Selenium, Copper Cl, Carnitor, Infuvitm Pediat, Rx O
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Drugs)·D-1141-2015·2015-06-24

    NEXIUM Capsules Recalled Due to Presence of SEROQUEL XR Tablets

    AstraZeneca is recalling NEXIUM capsules because a retail pharmacist found SEROQUEL XR tablets in an unopened bottle.

    Product
    NEXIUM¿ (esomeprazole magnesium), Delayed-Release capsules, 20 mg, 30-count bottle, Rx only, Manufactured for AstraZeneca LLC, Wilmington, Distributed by AstraZeneca, AB, Sodertalje, Sweden. NDC 00186-5020-31.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1128-2015·2015-06-17

    Montana Compounding Pharmacy Recalls Alprostadil Injectable Due to Sterility Concerns

    Montana Compounding Pharmacy is recalling Alprostadil injectable vials due to lack of assurance of sterility and objectionable conditions observed during an FDA inspection.

    Product
    Alprostadil (PFE1), solution, 30 mcg/mL, injectable, 5 mL vial, Rx only, compounded by Montana Compounding Pharmacy, Missoula, MT
    Category
    Drug
    Distribution
    2 states
  • SevereFDA (Drugs)·D-1119-2015·2015-06-17

    Montana Compounding Pharmacy Recalls Avastin Syringes Due to Sterility Concerns

    Montana Compounding Pharmacy is recalling Avastin syringes because FDA inspectors observed objectionable conditions that raise concerns about sterility.

    Product
    Avastin, solution, 1.25 mg/0.05mL, Injectable, Syringe, Rx only, compounded by Montana Compounding Pharmacy, Missoula, MT
    Category
    Drug
    Distribution
    2 states
  • SevereFDA (Drugs)·D-1117-2015·2015-06-17

    Montana Compounding Pharmacy Recalls Alprostadil Injectable Due to Sterility Concerns

    Montana Compounding Pharmacy is recalling Alprostadil injectable vials because objectionable conditions were observed during an FDA inspection, raising concerns about sterility.

    Product
    Alprostadil (PFE1), Solution, 10 mcg/mL, injectable, 5 mL vial, Rx only, compounded by Montana Compounding Pharmacy, Missoula, MT
    Category
    Drug
    Distribution
    2 states
  • SevereFDA (Drugs)·D-1127-2015·2015-06-17

    Montana Compounding Pharmacy Recalls Trimix Injectable Due to Sterility Concerns

    Montana Compounding Pharmacy is recalling specific lots of Trimix injectable vials because FDA inspectors observed objectionable conditions that raise concerns about sterility.

    Product
    Trimix (PGE1;PHENT;PAP) (N), injectable, (100/10/297) 10UG, 5 mL vial, Rx only, compounded by Montana Compounding Pharmacy, Missoula, MT
    Category
    Drug
    Distribution
    2 states