The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

5276–5300 of 15266

  • HighNHTSA·21V542000·2021-07-20

    2021 Newmar Ventana motorhomes recalled for loose tie rod clamps

    Newmar Corporation is recalling certain 2021 Ventana motorhomes because tie rod clamps may be loose, potentially causing tie rod ends to break or detach and resulting in steering loss.

    Product
    NEWMAR — NEWMAR KOUNTRY STAR, VENTANA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V543000·2021-07-20

    Newell P50 Recalled for Window Adhesive Failure Risk

    Newell Coach Corp. is recalling 2008-2022 P50 vehicles because window vent adhesive may fail, causing the vent to detach and increasing crash risk.

    Product
    NEWELL — NEWELL P50
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V546000·2021-07-20

    2022 Kenworth Medium-Duty Trucks Windshield Defrost Failure Recall

    Certain 2022 Kenworth T680, T880, and W990 trucks have defective HVAC controls that may fail to operate the windshield defrost system, reducing driver visibility and increasing crash risk. PACCAR is replacing the HVAC control heads free of charge.

    Product
    KENWORTH — KENWORTH T880, W900, T680
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V544000·2021-07-20

    Osage Super Warrior Recall for Display Lockup Hazard

    Osage Industries is recalling one 2021 Super Warrior vehicle because the emergency lighting display may lock up, potentially delaying emergency efforts.

    Product
    OSAGE — OSAGE SUPER WARRIOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V545000·2021-07-20

    2022 Tiffin Phaeton motorhomes recalled for fuel hose fire risk

    Tiffin is recalling 2021-2022 Phaeton and Allegro Bus motorhomes with certain Cummins L9 diesel engines for a potential fuel leak that could cause a fire. The leak occurs between the fuel pump and remote filter head.

    Product
    TIFFIN — TIFFIN PHAETON, ALLEGRO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V540000·2021-07-20

    ShowHauler Recalls 2018-2020 Motorhomes Due to Window Adhesive Failure

    ShowHauler is recalling 2018-2020 Garage Coach, Toter Coach, and Motorhome vehicles because window vent adhesive may fail, posing a crash risk.

    Product
    SHOWHAULER — SHOWHAULER GARAGE COACH, MOTORHOME, TOTER COACH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V547000·2021-07-20

    School Bus Parking Brake May Fail, Increasing Crash Risk

    Daimler Trucks is recalling 267 school buses because the parking brake activation switch may fail to set the parking brake, increasing the risk of unintended vehicle movement and crashes.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V539000·2021-07-16

    Mercedes-Benz Recalls 2013 GLK250 Diesel Vehicles for Transmission Defect

    Mercedes-Benz is recalling 2013 GLK250 diesel vehicles because incorrect transmission parts may cause fluid leaks or module failure, increasing fire and crash risks.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLK250
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21E065000·2021-07-15

    Continental Recalls Hydraulic Brake Units Due to Welding Defect

    Continental Automotive is recalling specific Hydraulic Electronic MKC1 brake units because a welding deviation may cause the ABS rotor and shaft to separate, potentially reducing braking performance.

    Product
    SERVICE BRAKES, HYDRAULIC recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V533000·2021-07-15

    Ford Recalls 2021 F-150 Trucks for Brake Fluid Leak Risk

    Ford is recalling 2021 F-150 vehicles because brake fluid may leak into the electronic control unit, potentially reducing braking performance and increasing crash risk.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V537000·2021-07-15

    Ford Recalls 2013-2017 Explorers for Rear Suspension Toe Link Fracture Risk

    Ford is recalling 2013-2017 Explorers in 23 states and D.C. because road salt exposure can cause rear suspension parts to corrode and fracture, potentially leading to loss of steering control.

    Product
    FORD — FORD EXPLORER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V538000·2021-07-15

    Gillig Recalls 2020-2021 Low Floor Vehicles Due to Ammonia Exhaust Risk

    Gillig is recalling 2020-2021 Low Floor vehicles with Cummins L9 Diesel Engines because engine software may allow excessive ammonia into the exhaust, increasing injury risk.

    Product
    GILLIG — GILLIG LOW FLOOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V534000·2021-07-15

    2020–2021 Lincoln Aviator Wire Harness May Contact Compressor, Increasing Fire Risk

    2020–2021 Lincoln Aviators with 3.0L engines may have improperly secured wire harnesses that can contact the A/C compressor pulley, risking electrical damage and fire. Ford will inspect and secure the harness free of charge.

    Product
    LINCOLN — LINCOLN AVIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V536000·2021-07-15

    2020-2021 Ford F-350 Super Duty Pickup Trucks Rear Axle Housing Recall

    Ford is recalling 2020-2021 F-350 Super Duty pickup trucks with 6.7L diesel engines due to rear axle housing that may deform. Driveshaft separation could cause loss of drive power or unexpected vehicle movement, increasing crash risk.

    Product
    FORD — FORD F-350 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21E064000·2021-07-14

    Magna Steyr Fuel Tanks Recalled for Potential Welding Defects

    Magna International is recalling certain Magna Steyr fuel tanks due to improper welding that could cause leaks and increase fire risk.

    Product
    FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V532000·2021-07-14

    New Flyer Recalls 2021 XD35 and XD40 Buses for Ammonia Emissions

    New Flyer is recalling 28 model-year 2021 XD35 and XD40 buses because engine software may allow excessive ammonia emissions from the tailpipe.

    Product
    NEW FLYER — NEW FLYER XD35, XD40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21E063000·2021-07-13

    Cummins Recalls L9 Diesel Engines Due to Fuel Hose Leak Risk

    Cummins is recalling specific L9 Diesel Engines equipped with remote Stage 2 fuel filters because a fuel leak may occur from the hose between the fuel pump and filter head.

    Product
    FUEL SYSTEM, DIESEL:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V529000·2021-07-13

    Entegra and Jayco recreational vehicles recalled for window adhesive failure

    Jayco is recalling certain 2019-2021 recreational vehicles with Hehr 6400 series windows due to adhesive failure. The window vent may detach, increasing the risk of crash or injury.

    Product
    ENTEGRA — ENTEGRA, JAYCO ANTHEM, ASPIRE, INSIGNIA, CORNERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V530000·2021-07-13

    Micro Bird Recalls School Buses Due to Emergency Door Defect

    Micro Bird is recalling 2003-2022 school buses because the service door emergency release handle may bind, preventing evacuation in an emergency.

    Product
    MICRO BIRD — MICRO BIRD G5 SCHOOL BUS, MB II SCHOOL BUS, T-SERIES SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V531000·2021-07-13

    Micro Bird Transit Buses Recalled for Service Door Emergency Release Defect

    Micro Bird is recalling 1,323 transit buses because the service door emergency release handle may bind, preventing evacuation in an emergency.

    Product
    MICRO BIRD — MICRO BIRD G5 TRANSIT BUS, MB II TRANSIT BUS, T-SERIES TRANSIT BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V527000·2021-07-12

    2021 Mercedes-Benz side crash sensor connector defect affects airbag deployment

    Mercedes-Benz is recalling certain 2020-2021 models because side crash sensor connectors may come loose, delaying airbag and seatbelt activation during side impact crashes. Dealers will inspect and replace sensors at no cost.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ S 560, GLC 300, AMG GLC63, G 550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V526000·2021-07-12

    Mercedes-Benz Recalls 2020 GLB 250 for Electrical Fire Risk

    Mercedes-Benz is recalling 2020 GLB 250 vehicles because an incorrect voltage converter socket may cause excessive voltage in the second-row power outlet, increasing fire risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLB 250
    Category
    Vehicle
    Distribution