The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1176–1200 of 39948

  • HighFDA (Devices)·Z-1864-2026·2026-04-29

    Soft-Vu Angiographic Catheter Cobra Non-Braided Manufacturing Defect

    Angiodynamics, Inc. recalls Soft-Vu Angiographic Catheter, Cobra (1), Non-Braided devices due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Cobra (1), Non-Braided; SOFT-VU CB1 4F X 100CM 038 NB 0SH; Catalog No.: 10714017; Product/UPN No.: H787107140175 (Box), H787107140170 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1920-2026·2026-04-29

    IV Administration Sets from Windstone Medical for Infusion Pump Systems

    Windstone Medical Packaging is recalling Custom Convenience Kits Pre Op Kit units due to potential backflow of medication between IV containers and risk of priming failure in gravity and pump administration sets.

    Product
    Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1852-2026·2026-04-29

    Olympus Thunderbeat II shears 25 cm may shed a distal tip component

    Olympus is recalling Thunderbeat II Shears with Ultrasonic Mode, 5 mm and 25 cm, because a distal tip component may detach during use. 365 units are affected.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 25cm. Model Number: TB2-0525FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1916-2026·2026-04-29

    MAC two-lumen central venous kits recalled over incorrectly manufactured adhesive

    The MAC Two-Lumen Central Venous Access Kit is being recalled after a supplier notified the firm that the liquid adhesive used in the device was incorrectly manufactured.

    Product
    MAC" Two-Lumen Central Venous Access Kit for use with 7.5 - 8 Fr. Catheters REF ASK-11142-LC2 UDI code: (01)10801902206807(17)270531(11)251211(10)33F25M0670 The MAC Multi-Lumen Central Venous Access Device permits short-term (<30 days) venous access and catheter introduction
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1938-2026·2026-04-29

    Diversatek Healthcare Viper Balloon Dilator Inflation Tag Labeling Error

    Diversatek Healthcare is recalling Viper 3-Stage Fixed Wire Balloon Dilators because the catheter inflation tag may contain incorrect part numbers and balloon diameter and pressure specifications.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Fixed Wire Balloon Dilator, 6mm-7mm-8mm, REF 1204-08
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1807-2026·2026-04-29

    Ultraviolet-C Germicidal Wand Recalled for Unsafe UVC Radiation Exposure

    Uvlizer handheld UV-C wands may expose users and bystanders to ultraviolet-C radiation levels above international safety limits during normal use, posing risk of skin and eye injury.

    Product
    The product is a handheld ultraviolet-C germicidal wand and contains two low-pressure mercury bulbs with a peak emission wavelength at 254 nm.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1941-2026·2026-04-29

    Diversatek Viper Wire Guided Balloon Dilator Inflation Tag Incorrect

    Diversatek Healthcare is recalling Viper 3-Stage Wire Guided Balloon Dilators because the attached inflation tag may contain an incorrect part number with wrong balloon diameter sizes and inflation pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 18mm-19mm-20mm, REF 1205-20
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1862-2026·2026-04-29

    Soft-Vu Angiographic Catheter, Kumpe, Non-Braided manufacturing defect

    Angiodynamics is recalling Soft-Vu Angiographic Catheter, Kumpe, Non-Braided devices due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 65CM 038 NB 0SH; Catalog No.: 10714014; Product/UPN No.: H787107140145 (Box), H787107140140 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1915-2026·2026-04-29

    Arrowg+ard Blue Plus four-lumen CVC kits recalled over adhesive manufacturing

    Pressure Injectable Arrowg+ard Blue Plus Four-Lumen CVC Kits are being recalled after a supplier notified the firm that the liquid adhesive was incorrectly manufactured.

    Product
    Pressure Injectable Arrowg+ard Blue Plus¿ Four-Lumen CVC Kit REF ASK-45854-PUPM1 UDI code: (01)10801902159578(17)270531(11)251205(10)33F25M0011 The Arrowg+ard technology is intended to provide protection against catheter-related bloodstream infections (CRBSIs). It is not int
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1863-2026·2026-04-29

    Soft-Vu Angiographic Catheter Berenstein Non-Braided Device Recall

    Angiodynamics is recalling Soft-Vu Angiographic Catheters (Berenstein, Non-Braided) due to a manufacturing defect that may prevent the guidewire from passing through the catheter hub. The defect affects 1,030 units distributed worldwide.

    Product
    Soft-Vu Angiographic Catheter, Berenstein, Non-Braided; SOFT-VU BER 4F X 100CM 038 NB 0SH; Catalog No.: 10714016; Product/UPN No.: H787107140165 (Box), H787107140160 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1928-2026·2026-04-29

    Central Line Dressing Kit containing non-sterile alcohol prep pads recalled

    LSL Healthcare's Central Line Dressing Kit (Model 2717H) is being recalled because it contains Webcol Large Alcohol Prep Pads that were found to be non-sterile. The kits were distributed nationwide in Maryland, Illinois, and Minnesota.

    Product
    LSL Healthcare, Central Line Dressing Kit, Model/Catalog Number: 2717H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1853-2026·2026-04-29

    Olympus Thunderbeat II shears 35 cm may shed a distal tip component

    Olympus is recalling Thunderbeat II Shears with Ultrasonic Mode, 5 mm and 35 cm, because a distal tip component may detach during use. 3,360 units are affected.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 35cm. Model Number: TB2-0535FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1929-2026·2026-04-29

    LSL Healthcare Central Line Dressing Change Kit Recalled for Non-Sterility

    LSL Healthcare is recalling its Standard Central Line Dressing Change Kit (Model 2717J) because the included Webcol Large Alcohol Prep Pads were found to be non-sterile.

    Product
    LSL Healthcare, Standard Central Line Dressing Change Kit, Model/Catalog Number: 2717J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1940-2026·2026-04-29

    Diversatek Viper balloon dilator tags may show incorrect inflation parameters

    Diversatek Viper 3-Stage Wire Guided Balloon Dilators are being recalled because the catheter inflation tag may show an incorrect part number with wrong balloon diameters and pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 15mm-16.5mm-18mm, REF 1205-18
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1872-2026·2026-04-29

    AccuVu Angiographic Catheter recall due to manufacturing defect

    Angiodynamics is recalling AccuVu Angiographic Catheters due to a manufacturing defect that may prevent a guidewire from passing through the catheter hub. The defect could interfere with proper device function during medical procedures.

    Product
    AccuVu Angiographic Catheter, Omni Flush, Non-Braided, With 2 R/O Markers; ACCU-VU OF 4F X 70CM 035 NB 6SH 2 R/O 2CM; Catalog No.: 13709005; Product/UPN No.: H787137090055 (Box), H787137090050 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1904-2026·2026-04-29

    Olympus OER-ELITE Endoscope Reprocessor Connecting Tubes Recall

    Olympus Corporation of the Americas is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2116) because the Version 2 reprocessor connecting tube lock levers may fail prematurely.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2116.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1870-2026·2026-04-29

    Soft-Vu Angiographic Catheter Omni Flush Non-Braided Defect Recall

    Angiodynamics is recalling Soft-Vu Angiographic Catheters (Omni Flush, Non-Braided) due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Omni Flush, Non-Braided; SOFT-VU OF 4F X 65CM 035 NB 6SH; Catalog No.: 10732301; Product/UPN No.: H787107323015 (Box), H787107323010 (Pouch); Box Quantity: 10 units;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1912-2026·2026-04-29

    Arrow Percutaneous Sheath Introducer Catheter Recall Due to Adhesive Defect

    Arrow International is recalling 115 units of its percutaneous sheath introducer with 7.5–8 Fr catheter because the liquid adhesive was incorrectly manufactured by a supplier. The product is used for venous access and central circulation catheterization.

    Product
    PERCUTANEOUS SHEATH INTRODUCER with 7.5 - 8 Fr. Catheter REF ASK-09903-MGH3 UDI code: (01)10801902159127(17)270331(11)251203(10)33F25J0352 The Arrow¿ percutaneous sheath introducer permits venous access and catheter introduction to the central circulation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1875-2026·2026-04-29

    AccuVu Angiographic Catheter recalled for guidewire passage defect

    Angiodynamics is recalling the AccuVu Angiographic Catheter (Pigtail, Non-Braided) due to a manufacturing defect that may prevent a properly sized guidewire from passing through the catheter hub's inner diameter.

    Product
    AccuVu Angiographic Catheter, Pigtail, Non-Braided, With 21 R/O Markers; ACCU-VU PT 4F X 70CM 035 NB 10SH 21 R/O 1CM; Catalog No.: 13709804; Product/UPN No.: H787137098045 (Box), H787137098040 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1874-2026·2026-04-29

    AccuVu Angiographic Catheter, Omni Flush, Non-Braided Defect Recall

    Angiodynamics recalls AccuVu Angiographic Catheters due to a manufacturing defect that may prevent guidewires from passing through the catheter hub. The affected devices were distributed worldwide.

    Product
    AccuVu Angiographic Catheter, Omni Flush, Non-Braided, With 21 R/O Markers; ACCU-VU OF 4F X 70CM 035 NB 6SH 21 R/O 1CM; Catalog No.: 13709704; Product/UPN No.: H787137097045 (Box), H787137097040 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1859-2026·2026-04-29

    Soft-Vu pigtail angiographic catheters may block the appropriately sized guidewire

    Soft-Vu Pigtail Angiographic Catheters are being recalled because a manufacturing defect may prevent an appropriately sized guidewire from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Pigtail, Non-Braided; SOFT-VU PT 4F X 65CM 038 NB 10SH; Catalog No.: 10714002; Product/UPN No.: H787107140025 (Box), H787107140020 (Pouch); Box Quantity: 10 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1877-2026·2026-04-29

    Medline Convenience Kits With Syringes Recalled for Unapproved Design Changes

    Medline Industries is recalling Convenience Kits containing 10mL polycarbonate colored syringes due to unapproved design changes made outside of FDA 510(k) clearance. The recall affects 270,311 units distributed nationwide and internationally.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes ADULT CATH PACK-LF DYNJ38395G ANGIO DRAPE PACK (ADLUG)642-LF DYNJ47665F DYNJ47665G ANGIO KIT PACK DYNJ83746 DYNJ83746A ANGIO PACK DYNJ30565G DYNJ51239C DYNJ66631A DYNJ6920
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1808-2026·2026-04-29

    Handheld UV-C germicidal wand recalls for excessive radiation exposure

    Uvlizer handheld UV-C germicidal wands may expose users and nearby people to ultraviolet radiation at levels above international safety guidelines for skin and eye protection.

    Product
    The product is a handheld ultraviolet-C germicidal wand and contains a combination of five UV-A and UV-C LED lights. The product comes in two configurations: UV-C x 1; UV-A x 4, or UV-C x 2; UV-A x 3. The product has two peak emission wavelengths at 274 nm and 397 nm.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1939-2026·2026-04-29

    Diversatek Healthcare Viper Balloon Dilator catheter inflation tag error

    Diversatek Healthcare is recalling Viper 3-Stage Wire Guided Balloon Dilators because the catheter inflation tag may contain an incorrect part number with wrong balloon diameter sizes and inflation pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 12mm-13.5mm-15mm, REF 1205-15
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1861-2026·2026-04-29

    Angiodynamics Soft-Vu Angiographic Catheter Cobra Non-Braided Recall

    Angiodynamics is recalling specific lots of Soft-Vu Angiographic Catheter, Cobra (2), Non-Braided devices due to a manufacturing defect that may prevent guidewire passage through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Cobra (2), Non-Braided; SOFT-VU CB2 4F X 65CM 038 NB 0SH; Catalog No.: 10714011; Product/UPN No.: H787107140115 (Box), H787107140110 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide