The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1026–1050 of 5027

  • SevereFDA (Devices)·Z-1512-2024·2024-04-24

    Dräger Perseus A500 Anesthesia Workstation Recalled for Unexpected Battery-Power Shutdowns

    Draeger Medical is recalling approximately 16,841 Dräger Perseus A500 Anesthesia Workstations due to unexpected shutdown while operating on battery power. The devices have been distributed nationwide and internationally.

    Product
    Dr¿ger Perseus A500 Anesthesia Workstation
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1502-2024·2024-04-24

    Philips Trilogy EV300 Ventilator False Power Alarm Defect Recall

    Philips is recalling 56,012 Trilogy EV300 ventilators due to a software defect that can trigger a false Battery Depleted or Loss of Power alarm despite adequate power, risking sudden loss of ventilation.

    Product
    Trilogy EV300, all software versions except 1.05.06.00. Ventilator for pediatric and adult patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1500-2024·2024-04-24

    Philips Garbin EVO Ventilator False Battery Alarm Causes Ventilation Loss

    Philips Respironics recalls 1,233 Garbin EVO ventilators. A software defect in the battery and power alarm system may cause sudden loss of ventilation despite adequate power supply.

    Product
    Garbin EVO, all software versions except 1.05.06.00. Ventilator for pediatric and adult patients. (sold outside US)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1503-2024·2024-04-24

    Trilogy Evo O2 Ventilator Recalled for Potential Sudden Loss of Ventilation

    Philips Respironics is recalling 789 Trilogy Evo O2 ventilators due to a software defect that can trigger a false power alarm despite sufficient power, potentially causing sudden loss of ventilation in pediatric and adult patients.

    Product
    Trilogy Evo O2, all software versions except 1.05.06.00. Ventilator for pediatric and adult patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1535-2024·2024-04-24

    Medical Device Airway Monitor Software Defect Prevents Obstruction Detection

    A software anomaly in SonarMed's AW-M0001 airway monitor prevents detection of partial airway obstructions in 2.5mm and larger sensors. The device may fail to alert clinicians to blockages, affecting approximately 145 units across 19 states.

    Product
    AW-M0001 SONARMED MONITOR. Used in conjunction with SonarMed Acoustic Sensors for airway monitoring.
    Category
    Medical Device
    Distribution
    17 states
  • SevereFDA (Devices)·Z-1504-2024·2024-04-24

    Trilogy Evo Ventilator Recall Due to Potential Loss of Ventilation

    Philips Respironics is recalling the Trilogy Evo ventilator (76,713 units) because it may suddenly stop ventilating when a false Battery Depleted or Loss of Power alarm triggers despite sufficient power available.

    Product
    Trilogy Evo, all software versions except 1.05.06.00. Ventilator for pediatric and adult patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1484-2024·2024-04-17

    Ivenix Infusion System Software Recalled for Potential Dosing Anomalies

    Fresenius Kabi USA is recalling Ivenix Infusion System software version 5.8.0 for anomalies that could cause incorrect medication dosing or therapy delays. The Class I recall affects 17 units across 13 US states.

    Product
    LVP Software of the Ivenix Infusion System (IIS), Version 5.8.0.
    Category
    Medical Device
    Distribution
    13 states
  • SevereFDA (Devices)·Z-1357-2024·2024-04-10

    Phantom 2 Nasal Vented Mask recalled due to magnetic device interference risk

    SleepNet is recalling the Phantom 2 Nasal Vented Mask to update contraindications and warning information related to magnets in the device. The recall affects 2,417 units distributed worldwide.

    Product
    Phantom 2 Nasal Vented Mask
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1353-2024·2024-04-10

    Mojo 2 Full Face Vented Mask Recalled: Magnet Contraindications Updated

    SleepNet Corporation is recalling 2,787 units of the Mojo 2 Full Face Vented Mask due to updates needed for contraindications and warning language regarding magnets in the device. Worldwide distribution.

    Product
    Mojo 2 Full Face Vented Mask, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1351-2024·2024-04-10

    Mojo Full Face CPAP Mask Recall: Magnet Safety Update

    SleepNet Corporation is recalling 23,042 Mojo Full Face CPAP masks worldwide because the masks contain magnets that require updated contraindications and warning language.

    Product
    Mojo Full Face with Headgear, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1356-2024·2024-04-10

    iQ 2 Nasal Vented Mask Recalled for Magnet Safety Warnings

    SleepNet Corporation is recalling the iQ 2 Nasal Vented Mask due to magnets requiring updated contraindication and warning language. Approximately 2,477 units distributed worldwide are affected.

    Product
    iQ 2 Nasal Vented Mask
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1354-2024·2024-04-10

    Mojo 2 Full Face Non Vented Mask Recalled for Magnet Safety Concerns

    SleepNet Corporation is recalling Mojo 2 Full Face Non Vented Masks due to magnets in the device and updated contraindications and warnings. The recall affects 2,107 units distributed worldwide.

    Product
    Mojo 2 Full Face Non Vented Mask, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1355-2024·2024-04-10

    Mojo 2 CPAP Masks Recalled Worldwide for Magnet Safety Contraindication Update

    SleepNet Corporation is recalling Mojo 2 Full Face CPAP masks (1,268 units worldwide) to update contraindications and warning language due to magnets in the masks. The FDA classified this as a Class I recall.

    Product
    Mojo 2 Full Face AAV Non Vented Mask, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1352-2024·2024-04-10

    Mojo Non Vented Full Face Mask warning updated for magnet hazard

    SleepNet is updating safety warnings and contraindications for its Mojo Non Vented Full Face Mask due to magnet content. All 11,874 affected units are subject to this warning update.

    Product
    Mojo Non Vented Full Face Mask with Headgear, All Sizes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1286-2024·2024-04-03

    Nimbus II Infusion Pump Systems Recalled for Multiple Potential Device Failures

    InfuTronix is recalling 52,328 Nimbus II Infusion Pump Systems due to potential failure modes including battery failure, system errors, drug product leakage, flow rate issues, and housing damage. The devices will no longer be available or supported after June 20, 2024.

    Product
    Nimbus II Infusion System; Nimbus II PainPRO IT1053; Nimbus II Flex IT1062; Nimbus II Plus IT1078; Nimbus II EpiD IT1124; Nimbus II EMS IT1063; Ambulatory Infusion Pump and components
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1302-2024·2024-04-03

    Boston Scientific steerable sheath devices recalled due to manufacturing defect risk

    Boston Scientific is recalling 461 POLARSHEATH Steerable Sheath devices due to a manufacturing tooling error that may cause inner sheath delamination and potential fragment release during medical procedures.

    Product
    Boston Scientific POLARSHEATH Steerable Sheath 12F, REF M004CRBS3050
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1374-2024·2024-04-03

    Obsidio Conformable Embolic coils recalled for bowel-ischemia risk

    Boston Scientific recalled 985 Obsidio Conformable Embolic coils because using the aliquot delivery technique for lower GI bleeding poses a high risk of bowel ischemia requiring major surgery.

    Product
    Obsidio Conformable Embolic, Material Numbers (UPN): a) M0013972001010, b) M0013972101010
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1285-2024·2024-04-03

    Nimbus Ambulatory Infusion Pump recalled due to multiple failure modes

    InfuTronix is recalling Nimbus Infusion Pump Systems (Nimbus Flex, Nimbus PainPro) due to potential battery failure, system errors, drug leakage, flow rate abnormalities, and housing damage. About 52,328 units are affected nationwide.

    Product
    Nimbus Administration Set; Nimbus Flex; Nimbus PainPro (a.k.a. Halo Ambulatory Infusion System); Catalog Number IT1025. Ambulatory Infusion Pump and components
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1326-2024·2024-04-03

    Catheter Extension Recalled by Fresenius Due to Chemical Leachables

    Fresenius is recalling 479,978 stay-safe Luer Lock Catheter Extensions due to chemical leachables in the tubing. Healthcare providers should contact the manufacturer for replacement information.

    Product
    stay-safe /Luer Lock Catheter Ext. 18 in
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1382-2024·2024-04-03

    Surgical Tracecarts Recalled Due to Defective Foley Catheter Component

    DeRoyal Industries is recalling 134 GeoMed Custom Tracecarts distributed in Florida that contain a recalled Foley catheter component. Affected units carry specific lot numbers with expiration dates from February 2024 through May 2025.

    Product
    GeoMed Custom Tracecarts, REF Numbers: a) 53-1831 ORTHO TOTAL JOINT TRACECART, b) 53-1836 GENERAL SURGERY TRACECART
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1324-2024·2024-04-03

    FDA Recalls stay-safe Luer Lock Adapter for Chemical Leachables

    The FDA is recalling approximately 828,954 stay-safe Luer Lock Adapters due to chemical leachables identified in the peroxide cross-linked tubing. The nationwide recall affects all lots of Model Number 050-95003.

    Product
    stay-safe /Luer Lock Adapter 4 in
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1325-2024·2024-04-03

    Stay-safe Luer Lock catheter extension recalled for chemical leachables

    Fresenius is recalling 663,221 stay-safe Luer Lock catheter extension units nationwide due to chemical leachables (NDL PCBAs) identified in the tubing.

    Product
    stay-safe /Luer Lock Catheter Ext. 12 in
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1327-2024·2024-04-03

    FDA Recalls Fresenius Catheter Extension Tubing Due to Chemical Leachables

    Fresenius Medical Care is recalling 105,700 stay-safe /Luer Catheter Extension 6 in devices nationwide due to chemical leachables identified in the peroxide cross-linked tubing. FDA classified this as a Class I recall.

    Product
    stay-safe /Luer Catheter Ext. 6 in
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1323-2024·2024-04-03

    Catheter Extension Tubing Recalled Due to Identified Leachable Substances

    Fresenius Medical Care is recalling 114,982 stay-safe Safe Lock Catheter Extensions due to peroxide cross-linked tubing leachables. Patients and healthcare providers are advised to discontinue use and contact the manufacturer for replacement.

    Product
    stay-safe /Safe Lock Catheter Ext. 12 in
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1275-2024·2024-03-27

    Smiths Medical Pneupac Plus 300 Ventilator Cycling Malfunction

    Smiths Medical Pneupac Plus 300 ventilators may intermittently deliver continuous airflow instead of cycling breaths as designed. This malfunction affects 2,902 units distributed worldwide.

    Product
    smiths medical Pneupac paraPAC plus 300 ventilator kit without PEEP and CPAP, REF P300NUS
    Category
    Medical Device
    Distribution
    Distributed nationwide