The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7801–7825 of 27441

  • SevereFDA (Devices)·Z-1900-2023·2023-07-05

    FDA Recalls Slick Set Uncuffed Endotracheal Tubes for Connector Disconnection

    Teleflex is recalling approximately 2,550 Slick Set Uncuffed Endotracheal Tubes (REF 150020) due to reports of 15mm connector disconnection.

    Product
    Slick Set Uncuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 150020
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1946-2023·2023-07-05

    Preformed AGT oral endotracheal tube connector disconnection recalled

    Teleflex LLC recalls 14,780 preformed AGT oral endotracheal tubes due to reports of 15mm connector disconnection. Units were distributed nationwide.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111780065
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1935-2023·2023-07-05

    Endotracheal Tubes Recalled Due to Connector Disconnection Issues

    Teleflex LLC is recalling 17,102 Endotracheal Tubes (REF 100382040) following reports of disconnection of the 15mm connector from the tube. The affected units were distributed nationwide, including Puerto Rico.

    Product
    Endotracheal Tube oral/nasal uncuffed/plain - Murphy, REF 100382040
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1944-2023·2023-07-05

    Endotracheal Tube Connector Disconnection Recalls 14,480 Units

    Teleflex is recalling 14,480 Preformed AGT Oral Endotracheal Tubes nationwide due to reports of 15mm connector disconnection from the tube during use.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111780055
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1903-2023·2023-07-05

    Endotracheal Tube Connector Failure Recall: Teleflex Slick Set Nationwide

    Teleflex is recalling 510 units of Slick Set Endotracheal Tubes with reported connector disconnection issues. The defect may prevent proper airway management during critical medical use.

    Product
    Slick Set Uncuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 150035
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1857-2023·2023-07-05

    Flexi-Set Uncuffed Endotracheal Tubes recalled for connector disconnection risk

    TELEFLEX LLC recalls Flexi-Set Uncuffed Endotracheal Tube and Stylet Sets due to reports of the 15mm connector disconnecting from the tube. Approximately 16,400 units distributed nationwide are affected.

    Product
    Flexi-Set Uncuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 506540
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1833-2023·2023-07-05

    Teleflex Slick Set Endotracheal Tube Connector Disconnection Recall

    Teleflex is recalling Slick Set Cuffed Endotracheal Tube and Stylet Sets due to reports of disconnection of the 15mm connector from the endotracheal tube. The affected units were distributed nationwide.

    Product
    Slick Set Cuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 170080
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1859-2023·2023-07-05

    Flexi-Set Uncuffed Endotracheal Tube Sets recalled for connector disconnection

    Teleflex is recalling approximately 10,600 Flexi-Set Uncuffed Endotracheal Tube and Stylet Sets due to reports that the 15mm connector may disconnect from the tube during use.

    Product
    Flexi-Set Uncuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 506550
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1899-2023·2023-07-05

    RUSCHELIT Safety Clear Tracheal Tubes Recalled for Connector Disconnection

    TELEFLEX LLC recalls RUSCHELIT Safety Clear Tracheal Tubes due to reports of 15mm connector disconnection. The Class I recall affects 30,391 units distributed nationwide including Puerto Rico.

    Product
    RUSCHELIT Safety Clear Tracheal Tube, oral/nasal, Magill, REF 112480045
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1888-2023·2023-07-05

    Endotracheal Tubes Recalled Due to Connector Disconnection Risk

    TELEFLEX endotracheal tubes are being recalled due to reports of the 15mm connector disconnecting from the tube. The recall affects 860,472 units distributed nationwide, including Puerto Rico.

    Product
    Endotracheal Tube oral/nasal Murphy Eye, High Volume, Low Pressure Cuff, REF 112082070
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2020-2023·2023-07-05

    Orthopedic assembly screws with incorrect model number labeling and markings

    AEQUALIS FLEX REVIVE assembly screws were mislabeled during manufacturing, with some units marked as 0mm Standard actually being 0mm Short and vice versa. Surgeons must verify model numbers before use.

    Product
    AEQUALIS FLEX REVIVE Assembly Screw 0mm Short, Model Number ARS655118
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2002-2023·2023-07-05

    Perifix Epidural Anesthesia Kits Recalled for Incorrect Filter Straw

    B. Braun Medical recalled 16,070 Perifix epidural anesthesia kits that were assembled with an incorrect filter straw. The kits were distributed nationwide.

    Product
    Perifix¿ / Epidural anesthesia kit (10 count carton)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2051-2023·2023-07-05

    Exactech Ergo Impactor Handle Recalled for Component Dislodgement

    Exactech Ergo Impactor Handles are recalled because the ball and spring in the locking mechanism may dislodge during disassembly or use. Approximately 784 devices are affected.

    Product
    Exactech Ergo Impactor Handle, Catalog #321-09-05.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-2010-2023·2023-07-05

    Limacorporate Prima TT Orthopedic Baseplate Recalled for Manufacturing Defect

    Limacorporate is recalling 13 units of the Prima TT Genoid Modular Reverse TT Baseplate due to a manufacturing issue that may cause peripheral holes to be out of specification. Healthcare facilities should contact the manufacturer.

    Product
    REF 1975.14.800, Prima TT Genoid Modular Reverse TT Baseplate, Sterile R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2025-2023·2023-07-05

    Philips Respironics V60 Ventilator recalled for potential gas pathway contamination

    DRE Medical Group recalled 22 Philips Respironics V60 ventilators due to potential contamination in the gas pathway of retrofitted units. These devices may pose a serious health risk to patients.

    Product
    Philips Respironics V60 Ventilator-Intended to mechanically control or assist patient breathing by delivering a predetermined percentage of oxygen in the breathing gas. Model Number: R1053618 and R1076709. These are retrofitted device.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-2047-2023·2023-07-05

    Knee Prosthesis Femoral Segment Recalled Due to Specification Compliance Issue

    Waldemar Link is recalling 22 units of the LINK Endo-Model Modular Knee Prosthesis System Femoral Segment, Size 3, Left, because device segments may not meet specifications. The company discovered the issue through customer complaints.

    Product
    LINK Endo-Model Modular Knee Prosthesis System Femoral Segment, Size 3, Left
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-2046-2023·2023-07-05

    Knee Prosthesis System Components Recalled for Specification Non-Compliance

    Waldemar Link GmbH & Co. KG is recalling 21 units of LINK Endo-Model Modular Knee Prosthesis System Femoral Segment components because they may not meet manufacturing specifications. No injuries have been reported.

    Product
    LINK Endo-Model Modular Knee Prosthesis System Femoral Segment, Size 3, Right
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-2003-2023·2023-07-05

    Design Options Epidural Anesthesia Kit Recalled for Incorrect Filter Straw

    B. Braun Medical is recalling Design Options Epidural Anesthesia Kits because certain units were assembled with an incorrect filter straw. The recall affects approximately 3,560 kits distributed nationwide.

    Product
    Design Options¿ / Epidural anesthesia kit (10 count carton)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2037-2023·2023-07-05

    Dental Implant Abutments Recalled Due to Lack of FDA Clearance

    Implant Direct Sybron is recalling LEGACY SMARTBASE dental abutments distributed without FDA clearance. Performance characteristics have not been adequately established.

    Product
    LEGACY SMARTBASE, NE 3.0D 1MML, REF: 8730-81NE; LEGACY SMARTBASE, NE 3.0D 2MML, REF 8730-82NE; LEGACY SMARTBASE NARROW NE 3.5D, REF: 8735-80NNE; LEGACY SMARTBASE, NE 3.5D 2MML, REF: 8735-82NE LEGACY SMARTBASE NARROW NE 4.5D, REF: 8745-80NNE; LEGACY SMARTBASE. NE 4.5D, REF: 8
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2023-2023·2023-07-05

    Verigene nucleic acid test kits recalled for rare false-negative results

    Luminex Corporation recalls Verigene nucleic acid test kits that may rarely produce false-negative results due to hydrophobic properties in certain FLOQSwab lots. False-negative results could fail to detect enteric pathogens in patient samples.

    Product
    Verigene Enteric Pathogens Nucleic Acid Test (EP), REF 30-002-023
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2049-2023·2023-07-05

    LINK Endo-Model Knee Prosthesis Segments Recalled for Out-of-Specification Defects

    The FDA has recalled 13 LINK Endo-Model knee prosthesis femoral segments because they may not meet manufacturing specifications. The defects were discovered through customer complaints.

    Product
    LINK Endo-Model Modular Knee Prosthesis System Femoral Segment, Size 4, Left
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-2050-2023·2023-07-05

    Exactech Shoulder GPS Impactor Handle Recalled for Locking Mechanism Defect

    Exactech is recalling 250 units of its Shoulder GPS Impactor Handle due to a defect where the ball and spring in the locking mechanism can dislodge during disassembly or impaction. The defect could affect the device's function during surgical use.

    Product
    Exactech Shoulder GPS Impactor Handle, Catalog #531-07-05.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-2019-2023·2023-07-05

    Orthopedic Assembly Screws Recalled Due to Labeling and Size Swap Error

    Tornier recalled 55 AEQUALIS FLEX REVIVE Assembly Screws (Model ARS655101) due to a labeling swap where Standard-length units were marked Short, and vice versa. This could result in implantation of the wrong screw size during orthopedic surgery.

    Product
    AEQUALIS FLEX REVIVE Assembly Screw 0mm, Model Number ARS655101
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2039-2023·2023-07-05

    RayStation Radiation Therapy Software Recalled for Incorrect Dose Calculation

    RaySearch America is recalling RayStation radiation therapy treatment planning software due to a software bug that produces incorrect dose calculations. The error could lead to inappropriate treatment plans being approved for patient use.

    Product
    Radiation therapy software, RayStation standalone software treatment planning system. Model numbers: 8B, 8B SP1, 8B SP2, 9A, 9B, 9B SP1, 10A, 10A SP1 and 10B. Software versions: 8.1, 9.0, 9.1, 9.2, 10.0, 10.1.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-2024-2023·2023-07-05

    VERIGENE Clostridium difficile Nucleic Acid Test May Give False-Negative Results

    Luminex is recalling the VERIGENE C. difficile diagnostic test due to the possibility of false-negative results in rare instances caused by hydrophobic characteristics in specific FLOQSwab lots.

    Product
    VERIGENE Clostridium difficile Nucleic Acid Test, REF 30-002-022
    Category
    Medical Device
    Distribution
    Distributed nationwide