The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7451–7475 of 39968

  • HighFDA (Devices)·Z-1567-2024·2024-04-24

    MRI System Patient Support Table Floor Plate Installation Defect

    Philips Ingenia 3.0T CX MRI systems may have an incorrectly installed patient support table floor plate. This installation error could compromise the stability of the patient support table during use.

    Product
    Ingenia 3.0T CX, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1558-2024·2024-04-24

    Philips Evolution 3.0T MRI System patient table floor plate installation defect

    Philips Evolution 3.0T MRI systems may have an incorrectly installed patient support table floor plate, creating a potential safety risk. Affected facilities should verify proper installation.

    Product
    Evolution Upgrade 3.0T, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1526-2024·2024-04-24

    Trocar Needle Recall Due to Packaging Seal Strength Defect

    Cook Incorporated recalled 55 Trocar Needles (Lot 15786588) due to packaging that may not meet peel strength specifications, potentially compromising device sterility. Units were distributed nationwide and internationally.

    Product
    Trocar Needle - Used for dilating puncture sites or catheter tracts for percutaneous placement of devices for vascular and non-vascular applications such as in the venous, arterial, biliary and renal system REFERENCE PART NUMBER (RPN): DTN-18-20.0 ORDER NUMBER (GPN): G013
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1536-2024·2024-04-24

    Masimo Rad-G Pulse Oximeter Recall: Potential Automatic Power Loss

    Masimo Corporation is recalling 443 Rad-G pulse oximeters that may automatically power off and on, interrupting patient monitoring. Affected units are distributed worldwide.

    Product
    Masimo Rad-G, Pulse Oximeter with temperature (W/Sensor), REF:9210, Rx Only,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1522-2024·2024-04-24

    Marketing brochures for Baxter surgical vessel occluders contain inaccurate information

    Baxter Healthcare is recalling marketing brochures for surgical vessel occluders and related devices because the brochures contain information that does not match the official product instructions for use.

    Product
    Surgical Tools and Cardiovascular Specialty marketing brochures, Reference numbers: US-AS18-210002 Surgical Tools Brochure 2021, US-AS18-210004 Surgical Tools Website v1, and US-AS46-230002 CV Specialty Brochure US version which affect: Flo-Rester Disposable Internal Vessel O
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1529-2024·2024-04-24

    Gastrointestinal Suture Anchor Recalled Due to Packaging Seal Defect

    Cook Incorporated is recalling the Entuit Secure Adjustable Gastrointestinal Suture Anchor Set due to packaging that may have insufficient seal strength, potentially compromising device sterility. The recalled lot is distributed worldwide.

    Product
    Entuit Secure Adjustable Gastrointestinal Suture Anchor Set - Intended for anchoring the anterior wall of the stomach to the abdominal wall prior to introduction of interventional catheters. REFERENCE PART NUMBER (RPN): GIAS-SRM-ADJ-2 ORDER NUMBER (GPN): G35562
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1549-2024·2024-04-24

    Siemens Atellica Lab Analyzers Risk Falsely Elevated Cholesterol Results

    Siemens Atellica CH and CI analyzers may produce falsely elevated cholesterol and lipid test results (2–16% high) after iron tests. This affects clinical calibration, quality control checks, and patient test results.

    Product
    Atellica CH Iron3 - IVD use in the quantitative measurement of iron in human serum and plasma (lithium heparin and sodium heparin) using the Atellica¿ CI Analyzer and Atellica¿ CH Analyzer Siemens Material Number (SMN): 11537211
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1545-2024·2024-04-24

    CryoValve SG Heart Valve Recalled for Staphylococcus aureus Contamination

    Artivion is recalling one CryoValve SG cryopreserved heart valve contaminated with Staphylococcus aureus, detected during organ donation screening. No illnesses have been reported.

    Product
    CryoValve SG Cryopreserved Pulmonary Human Heart Valve
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1543-2024·2024-04-24

    Smiths Medical Medfusion Pump Guide Barrel Clamp Molding Defect Recall

    Smiths Medical is recalling Medfusion Guide Barrel Clamps due to a molding defect that could cause spring slippage, preventing the pump from recognizing or correctly identifying loaded syringes.

    Product
    Smiths Medical Medfusion Guide Barrel Clamp, Item number G6000716
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1555-2024·2024-04-24

    Philips Achieva 3.0TX PET-MRI Patient Support Table Installation Defect

    Philips is recalling the Achieva 3.0TX PET-MRI system because the patient support table floor plate may be incorrectly installed.

    Product
    Achieva 3.0TX for PET, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1581-2024·2024-04-24

    Philips Intera 1.5T MRI System Patient Support Table Installation Defect

    Philips is recalling certain Intera 1.5T MRI systems because the patient support table floor plate may be incorrectly installed, which could affect patient safety.

    Product
    Intera 1.5T Omni/Stellar, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1572-2024·2024-04-24

    Philips Intera 0.5T MRI System Patient Table Floor Plate Installation Defect

    Philips is recalling 14 Intera 0.5T MRI systems due to potential misinstallation of the patient support table floor plate, which could affect equipment stability and patient safety.

    Product
    Intera 0.5T Standard, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1580-2024·2024-04-24

    Philips MRI patient support table floor plate installation defect recall

    Philips is recalling 107 Intera 1.5T MRI systems worldwide due to potential incorrect installation of the patient support table floor plate, which may create safety risks during patient use.

    Product
    Intera 1.5T Master/Nova, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1583-2024·2024-04-24

    Philips MRI System Patient Support Table Installation Defect Recall

    Philips recalls 25 Intera 1.5T R11 MRI systems due to potential incorrect installation of the patient support table floor plate, which may affect patient safety during device operation.

    Product
    Intera 1.5T R11, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1523-2024·2024-04-24

    Surgical and Cardiovascular Device Marketing Brochures Recalled for Documentation Errors

    Baxter Healthcare is recalling surgical and cardiovascular device marketing brochures that contain information conflicting with the official Instructions for Use. The inaccurate content could lead to incorrect device use.

    Product
    Surgical Tools and Cardiovascular Specialty marketing brochures, Reference numbers: US-AS18-210002 Surgical Tools Brochure 2021, US-AS18-210004 Surgical Tools Website v1, and US-AS46-230002 CV Specialty Brochure US version which affect: Flo-Thru Intraluminal Shunt, Item Numbe
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1525-2024·2024-04-24

    Chiba Biopsy Needles Recalled for Potential Sterility Compromise

    Cook Incorporated is recalling Chiba Biopsy Needles due to packaging that may have low seal strength, potentially compromising device sterility. The recall affects 6,178 units distributed worldwide.

    Product
    Chiba Biopsy Needle - Used for aspiration biopsy. REFERENCE PART NUMBER (RPN) ORDER NUMBER (GPN): 1) DCHN-18-10.0 G01559 2) DCHN-18-10.0-U G05040 3) DCHN-18-15.0 G00850 4) DCHN-22-10.0 G00852 5) DCHN-22-10.0-U G03978 6) DCHN-22-15.0 G00012 7) DCHN-22-15.0-U G03314 8)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1564-2024·2024-04-24

    Philips Ingenia 1.5T CX MRI System Patient Support Table Installation Defect

    Philips has recalled 143 Ingenia 1.5T CX MRI systems due to potential incorrect installation of the patient support table floor plate affecting worldwide distribution.

    Product
    Ingenia 1.5T CX, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1593-2024·2024-04-24

    Microalbumin Calibrator Series Recall Due to Measurement Accuracy Issue

    FDA recalls Microalbumin Calibrator Series due to negative measurement bias that may misclassify patient results. Laboratories using affected batches should review quality control data and consider recalibration.

    Product
    Microalbumin Calibrator Series (mALB CAL)-IVD used to calibrate the Microalbumin Assay Catalog Number: MA1567
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1566-2024·2024-04-24

    Ingenia 3.0T magnetic resonance system patient support floor plate installation defect

    Philips is recalling Ingenia 3.0T MRI systems due to incorrect patient support table floor plate installation. Affected healthcare facilities should verify installation status and contact Philips for corrective action.

    Product
    Ingenia 3.0T, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1579-2024·2024-04-24

    Philips MRI System Patient Support Table Floor Plate Installation Defect

    Philips is recalling 12 Intera 1.5T MRI systems worldwide because the patient support table floor plate may be incorrectly installed. Healthcare facilities should verify proper installation.

    Product
    Intera 1.5T Explorer/Nova Dual, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1594-2024·2024-04-24

    Microalbumin Calibrator Series Recalled for Negative Bias and Patient Result Misclassification

    Randox Laboratories is recalling its Microalbumin Calibrator Series due to a negative bias in its calibration. This could misclassify patient results and affect Quality Control procedures by up to 12%.

    Product
    Microalbumin Calibrator Series (mALB CAL)-IVD to calibrate the Microalbumin Assay Catalog Number: MA2426
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1538-2024·2024-04-24

    Masimo Rad-G Pulse Oximeter automatic power cycling may cause monitoring loss

    Masimo Rad-G pulse oximeters may unexpectedly power off and on, potentially losing monitoring capability. About 4978 units affected worldwide.

    Product
    Masimo Rad-G, Pulse Oximeter (W/Patient Cable), REF:9849, Rx Only,
    Category
    Medical Device
    Distribution
    Distributed nationwide