The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7401–7425 of 39968

  • HighFDA (Devices)·Z-1637-2024·2024-05-01

    Medical diagnostic test kits recalled due to misaligned results window

    Quidel InflammaDry MMP-9 test kits are recalled because the test results window is misaligned. Positive results may be hidden from view, potentially causing false negative readings.

    Product
    QUIDEL InflammaDry MMP-9 Test, REF: PRS-ID-20, 20 Tests
    Category
    Medical Device
    Distribution
    44 states
  • HighFDA (Devices)·Z-1599-2024·2024-05-01

    ACUSON Juniper ultrasound systems display incorrect cardiac measurements

    Siemens ACUSON Juniper ultrasound systems may display the wrong cardiac measurement value when configured to show minimum or maximum values, potentially leading to misdiagnosis.

    Product
    ACUSON Juniper Diagnostic Ultrasound System, REF: 11335791, and ACUSON Juniper Select Diagnostic Ultrasound System, REF: 11653093, running software version VA10x with DICOM SR Cardiac option, from VB10A to VB10G, VB11A, VB11B, VB30B and VB30C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1632-2024·2024-05-01

    Hip replacement acetabular shells recalled for deburring defect

    Howmedica is recalling hip replacement acetabular shells that may have excessive deburring, resulting in a smooth surface on the shell edge. The recall affects devices distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER64H- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-64H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1606-2024·2024-05-01

    Alcon Custom Paks Surgical Procedure Packs recalled for cannula defects

    Alcon is recalling Custom Paks Surgical Procedure Packs containing Oasis 27Ga Chang Hydrodissection Cannulas due to complaints of particulates, residue, occlusions, and bent tips in sterile cannulas used in ophthalmic surgery.

    Product
    Various Alcon Custom Paks Surgical Procedure Pack containing Oasis 27Ga Chang Hydrodissection Cannulas. These Custom Paks are surgical procedure packs used by ophthalmic surgeons in a variety of ophthalmic surgeries. The Custom Pak is a collection of various ophthalmic surgical
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1690-2024·2024-05-01

    Philips Patient Information Center iX UPS devices recalled for potential power failure

    Philips is recalling certain Patient Information Center iX Uninterruptable Power Supply devices due to potential power supply failures that could cause the monitoring system to shut down, risking delays in detecting patient condition changes.

    Product
    Philips Patient Information Center (PIC) iX Uninterruptable Power Supply (UPS): 1. APC (Schneider Electric IT Corporation) 120V Uninterruptable Power Supply Model: SCL500RM1U 2. APC (Schneider Electric IT Corporation) 230V Uninterruptable Power Supply Model: SCL500R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1605-2024·2024-05-01

    Mariner RDX Pedicle Screw Heads Recalled for Intraoperative Cross-Threading Risk

    SeaSpine Orthopedics is recalling Mariner RDX pedicle screw heads because the thin lead-in thread poses a risk of cross-threading within the locking cap/screw head interface during surgery.

    Product
    Mariner RDX Polyaxial Head, REF: MX1-000020; Mariner RDX Extended Polyaxial Head, REF: MX1-000030; Mariner RDX Deformity Head, REF: MX1-000040; Mariner RDX Extended Deformity Head, REF: MX1-000050; Mariner RDX Trauma Head, REF: MX1-000060; Mariner RDX Extended Trauma Head. R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1627-2024·2024-05-01

    Hip Implant Acetabular Shell May Have Excessive Deburring Manufacturing Defect

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER66H hip implants because the acetabular shell may have excessive deburring, creating a smooth surface on the edge of the shell.

    Product
    TRIDENTII HEMI CLUSTER66H- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-66H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1687-2024·2024-05-01

    Water bottles used in dental treatment devices recalled for disassembly risk

    Electro Medical Systems is recalling water bottles used with AIRFLOW dental devices because certain bottle collars can disassemble under pressure during treatment or storage. No injuries have been reported.

    Product
    Brand Name: WATER BOTTLE Product Name: WATER BOTTLE Model/Catalog Number: EG-121 Software Version: N/A Product Description: These bottles are sold empty and are filled by the user with water fort dental treatments. The bottle is pressurized on the device during use. Componen
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1618-2024·2024-05-01

    Replacement Lead Wires Recalled for Risk of Treatment Delivery Failure

    EBI, LLC recalls 829 replacement lead wire assemblies (Part 1067724-2) distributed nationwide since May 1, 2023. Damaged wire sheaths may prevent therapeutic treatment signals from reaching electrodes, potentially delaying treatment.

    Product
    20" Lead Wires, Replacement Part Number: 1067724-2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1600-2024·2024-05-01

    ACUSON Redwood 1.0 ultrasound displays incorrect cardiac measurement values

    The ACUSON Redwood 1.0 Diagnostic Ultrasound System may display the last measured cardiac value instead of the minimum or maximum value as configured, potentially leading to misdiagnosis or improper patient management.

    Product
    ACUSON Redwood 1.0 Diagnostic Ultrasound System, REF: 11503314, running software version VA10A to VA10G
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1607-2024·2024-05-01

    Vanguard Knee System Tibial Bearing Recalled for Manufacturing Damage

    Biomet is recalling the Vanguard Knee System AS Tibial Bearing (Model 189082) due to possible damage during manufacturing. Affected units were distributed worldwide including the United States.

    Product
    Vanguard Knee System AS Tibial Bearing / DCM ArCom, 12 MM X 75 MM; Model Number 189082. The product is placed into a foil pouch with protective packaging in the form of a polyurethane bag, and sealed closed (inner barrier). The inner barrier is then placed into a PETG tray and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1624-2024·2024-05-01

    TRIDENTII HEMI hip prosthesis recalled for manufacturing defect

    Howmedica Osteonics is recalling TRIDENTII HEMI CLUSTER52E hip prostheses due to excessive deburring on the acetabular shell. The defect may increase risk of hip dislocation in high-risk patients.

    Product
    TRIDENTII HEMI CLUSTER52E-Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-52E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1628-2024·2024-05-01

    Hip implant recalled for acetabular shell deburring defect

    Howmedica Osteonics Corp. is recalling TRIDENTII PSL CLUSTER48D hip implants (Lot 16311453) due to excessive deburring on the acetabular shell edge, a manufacturing defect.

    Product
    TRIDENTII PSL CLUSTER48D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-48D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1622-2024·2024-05-01

    TRIDENTII HEMI hip implant recalled for acetabular shell manufacturing defect

    Howmedica Osteonics is recalling the TRIDENTII HEMI CLUSTER48D hip implant because the acetabular shell may have excessive deburring, resulting in a smooth surface on the shell edge.

    Product
    TRIDENTII HEMI CLUSTER48D-indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-48D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1631-2024·2024-05-01

    Hip replacement acetabular shell recalled for excessive deburring

    Howmedica Osteonics is recalling TRIDENTII PSL CLUSTER58F hip replacement acetabular shells due to excessive deburring. The manufacturing defect affects units distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER58F-Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-58F
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1619-2024·2024-05-01

    Lead Wire Replacement Parts Recalled for Sheath Damage and Treatment Signal Loss

    EBI, LLC is recalling 594 units of 48-inch lead wire replacement parts (part number 1067724-4) due to sheath damage that prevents therapeutic signals from reaching treatment electrodes.

    Product
    48" Lead Wires, Replacement Part Number: 1067724-4
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1629-2024·2024-05-01

    Hip replacement acetabular shell recalled for excessive deburring

    Howmedica Osteonics is recalling TRIDENTII PSL CLUSTER50D acetabular shells for hip replacements due to excessive deburring resulting in smooth edges on the shell.

    Product
    TRIDENTII PSL CLUSTER50D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-50D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1623-2024·2024-05-01

    Hip Implant Acetabular Shell Recalled for Manufacturing Defect

    Howmedica Osteonics is recalling TRIDENTII HEMI CLUSTER50D hip implant shells due to excessive deburring that may create a smooth edge, potentially affecting implant fit. Affected units were distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER50D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-50D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0590-2024·2024-05-01

    Tissue Processor Recall: HistoCore PEGASUS May Produce Damaged Specimens

    Leica is recalling 98 HistoCore PEGASUS automated tissue processors due to a protocol configuration error that can produce poorly processed or damaged biopsy specimens.

    Product
    Leica HistoCore PEGASUS (PROCESSOR, TISSUE, AUTOMATED)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1615-2024·2024-05-01

    LightStrike Blackout Curtains Recalled Due to Inadequate UV and Ozone Protection

    XENEX LightStrike Blackout Curtains are recalled due to inadequate protection against UV and ozone exposure. Bystanders in rooms during device operation may experience temporary skin reddening, eye irritation, nausea, and headache.

    Product
    LightStrike Blackout Curtains, Part numbers; 610-00008, 610-00009, 610-00019, 610-00020, and 610-00024, used with the LightStrike Germ-Zapping Robots Models: PXUV4D, PXUV5D, LSMUV6-FT, or LSMUV6-SL, for whole room microbial reduction.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1602-2024·2024-05-01

    Abbott Alinity m System camera generates error with certain tubes

    Abbott Molecular is recalling 1,012 Alinity m System units due to a camera detection issue that generates an error message when certain third-party transport medium tubes lack a sample rack retention bar.

    Product
    Alinity m System, Part Number: 08N53-002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1686-2024·2024-05-01

    Cleaner Bottles May Disassemble Under Pressure During Treatment

    EMS CLEANER BOTTLES (Model EG-1000) for dental prophylaxis systems may disassemble under pressure during treatment or storage. FDA Class II recall; no injuries reported.

    Product
    Brand Name: CLEANER BOTTLE Product Name: CLEANER BOTTLE Model/Catalog Number: EG-1000 Software Version: N/A Product Description: CLEANER bottles used with EMS AIRFLOW PROPHYLAXIS MASTER / EMS AIRFLOW ONE devices to clean the water lines. The bottle is placed on the device du
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1608-2024·2024-05-01

    NexGen CR-Flex Femoral Components Recalled for Bonding Defect

    Zimmer is recalling 5,546 units of NexGen CR-Flex Femoral Components due to a manufacturing defect where the fiber metal pad fails to bond properly to the substrate. Patients with these implants should contact their healthcare provider.

    Product
    NexGen CR-Flex Femoral Component, Size E and Size E Minus (E-). Component of the NexGen CR-Flex Porous Femur System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1635-2024·2024-05-01

    Palindrome Precision H Chronic Catheter Kit may lack labeled heparin coating

    Covidien is recalling 878 units of Palindrome Precision H Chronic Catheter Kits that may lack the heparin anticoagulant coating indicated on the label, potentially reducing clot prevention during hemodialysis.

    Product
    Palindrome Precision H Chronic Catheter Kit 14.5 Fr/Ch (4.8mm) x 23 cm (Symmetrical Tip, Heparin Coating and Tal VenaTrac Stylet- Intended for acute and chronic hemodialysis, apheresis, and infusion. Model Number (CFN): 8888145044CP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1636-2024·2024-05-01

    Quidel InflammaDry MMP-9 Test: Misaligned Results Window May Cause False Negatives

    Quidel Corporation is recalling 104,300 units of InflammaDry MMP-9 diagnostic tests due to misalignment of the test results window. Positive results may be hidden and not visible, potentially leading to false negative readings.

    Product
    QUIDEL InflammaDry MMP-9 Test, REF: PRS-ID-20-U, 20 Tests
    Category
    Medical Device
    Distribution
    44 states