The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7376–7400 of 39968

  • HighFDA (Devices)·Z-1726-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plates May Have Improper Screw Locking

    A thread form defect in the locking holes of Zimmer surgical bone plates may prevent locking screws from securing properly, potentially causing loss of fixation during surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 4 Holes, 80 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1724-2024·2024-05-08

    Zimmer ZPLP Fibular Plate May Fail to Lock Properly During Surgery

    The ZPLP Distal Lateral Fibular Plate may have a thread defect preventing screws from locking properly, potentially compromising surgical fixation and requiring further intervention.

    Product
    ZPLP Distal Lateral Fibular Plate, Right, 8 Holes, 132 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-017-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1738-2024·2024-05-08

    Jackson-Pratt Drainage Kits Shipped Unsterilized in Voluntary Removal

    Cardinal Health is voluntarily removing Jackson-Pratt drainage kits (Lot 210751D6) that were shipped without sterilization. The unsterilized devices pose an infection risk if used in patient care.

    Product
    Jackson-Pratt Universal Connector PVC Tubing Anti Reflux Transparent Y, REF SU130-4601
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1702-2024·2024-05-08

    Abbott Cholestech LDX Battery Kit Recall: Potential Swelling Risk

    Abbott is recalling the Cholestech LDX Battery Kit due to a potential for battery swelling that could cause minor burns, cuts, abrasions, or electrical shock to users.

    Product
    Abbott Cholestech LDX Battery Kit, Model: 3LP656194-PCM-LD, PN: 55170
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1713-2024·2024-05-08

    Zimmer Periarticular Locking Plate screw-mating defect risks surgical fixation loss

    Zimmer's Periarticular Locking Plate System has a thread defect that may prevent proper screw locking, potentially causing loss of surgical fixation. Affected units distributed worldwide.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 12 Holes, 184 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-12
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1691-2024·2024-05-08

    Intellis AdaptiveStim Spinal Cord Stimulator unable to reprogram

    Medtronic Neuromodulation recalls the Intellis AdaptiveStim spinal cord stimulator because one device cannot be reprogrammed. Patients should consult their healthcare provider.

    Product
    Intellis AdaptiveStim Product Number 97715, Spinal Cord Stimulator
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1720-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate Recall: Locking Screw Malfunction Risk

    Zimmer orthopedic plates may have thread defects preventing locking screws from properly securing to the implant. This could delay surgery or cause loss of fixation requiring additional intervention.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 14 Holes, 210 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-14
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1723-2024·2024-05-08

    ZPLP Distal Lateral Fibular Plates: locking screws may not secure

    Zimmer is recalling ZPLP Distal Lateral Fibular Plates due to a threading defect in the locking holes that may prevent screws from properly securing. The defect could result in loss of surgical fixation.

    Product
    ZPLP Distal Lateral Fibular Plate, Right, 6 Holes, 106 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-017-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1612-2024·2024-05-01

    Route 92 Medical 070 Access System Recalled for Distal Tip Separation Risk

    Route 92 Medical 070 Access System catheters are recalled for potential distal tip separation during neurovasculature procedures. The defect affects 117 units distributed across 30 US states and New Zealand.

    Product
    Route 92 Medical, 070 Access System, REF 1004, Rxonly , Sterile EO. Used for introduction of interventional devices into the neurovasculature.
    Category
    Medical Device
    Distribution
    30 states
  • SevereFDA (Devices)·Z-1614-2024·2024-05-01

    Route 92 Medical Reperfusion System Recalled for Potential Device Separation

    Nineteen units of the Route 92 Medical 070 Reperfusion System may experience distal tip separation. Healthcare facilities should cease use of affected devices immediately.

    Product
    Route 92 Medical 070 Reperfusion System, REF 1003, Rxonly, SterileEO. Used for introduction of interventional devices into the neurovasculature and aspiration of thrombus in ischemic stroke patients.
    Category
    Medical Device
    Distribution
    30 states
  • SevereFDA (Devices)·Z-1613-2024·2024-05-01

    Route 92 Medical delivery catheter recalled due to tip separation risk

    Route 92 Medical is recalling Tenzing 7 delivery catheters because the distal tip may separate from the proximal marker band. The affected units were distributed across the US and New Zealand.

    Product
    Route 92 Medical, Tenzing 7 Delivery Catheter, REF 1005, Rx Only, Sterile EO. Used for introduction of interventional devices into the neurovasculature.
    Category
    Medical Device
    Distribution
    30 states
  • SevereFDA (Devices)·Z-1610-2024·2024-05-01

    Route 92 Medical Access System Recalled for Distal Tip Separation

    Route 92 Medical's Full Length 070 Access System (REF 7002) is recalled due to potential distal tip separation at the proximal marker band of the delivery catheters. This FDA Class I recall affects a device used in neurovasculature interventions distributed across the US and New Zealand.

    Product
    Route 92 Medical Full Length 070 Access System, REF 7002, Rxonly, SterileEO. Used for Introduction of interventional devices into the neurovasculature.
    Category
    Medical Device
    Distribution
    30 states
  • SevereFDA (Devices)·Z-1464-2024·2024-05-01

    VITEK 2 AST Test Kits: Ceftriaxone Concentration Error Risk

    Biomerieux Inc is recalling VITEK 2 AST test kits due to ceftriaxone concentration errors that could produce false susceptible results in antimicrobial susceptibility testing.

    Product
    VITEK 2 - AST Test kits (in vitro diagnostic test cards for antimicrobial susceptibility): a) AST-N334, REF 418984; b) AST-GN95, REF 421982; c) AST-GN99, REF 423102; d) AST-N390, REF 423340; e) AST-N391, REF 423341; f) AST-N392, REF 423342; g) AST-N395, REF 423491;
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1611-2024·2024-05-01

    Route 92 Medical Reperfusion System Potential Catheter Tip Separation

    Route 92 Medical recalls its Full Length 070 Reperfusion System due to potential distal tip separation at the proximal marker band, which could affect device delivery during interventional procedures.

    Product
    Route 92 Medical, Full Length 070 Reperfusion System, REF: 7001, Rxonly, SterileEO. Used for Introduction of interventional devices into the neurovasculature.
    Category
    Medical Device
    Distribution
    30 states
  • HighFDA (Devices)·Z-1618-2024·2024-05-01

    Replacement Lead Wires Recalled for Risk of Treatment Delivery Failure

    EBI, LLC recalls 829 replacement lead wire assemblies (Part 1067724-2) distributed nationwide since May 1, 2023. Damaged wire sheaths may prevent therapeutic treatment signals from reaching electrodes, potentially delaying treatment.

    Product
    20" Lead Wires, Replacement Part Number: 1067724-2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1599-2024·2024-05-01

    ACUSON Juniper ultrasound systems display incorrect cardiac measurements

    Siemens ACUSON Juniper ultrasound systems may display the wrong cardiac measurement value when configured to show minimum or maximum values, potentially leading to misdiagnosis.

    Product
    ACUSON Juniper Diagnostic Ultrasound System, REF: 11335791, and ACUSON Juniper Select Diagnostic Ultrasound System, REF: 11653093, running software version VA10x with DICOM SR Cardiac option, from VB10A to VB10G, VB11A, VB11B, VB30B and VB30C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1625-2024·2024-05-01

    TRIDENTII HEMI Hip Implant Acetabular Shell Deburring Defect Recall

    Howmedica Osteonics is recalling the TRIDENTII HEMI CLUSTER54E hip implant due to excessive deburring on the acetabular shell edge that may affect implant performance. The recall involves 225 units distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER54E- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-54E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1619-2024·2024-05-01

    Lead Wire Replacement Parts Recalled for Sheath Damage and Treatment Signal Loss

    EBI, LLC is recalling 594 units of 48-inch lead wire replacement parts (part number 1067724-4) due to sheath damage that prevents therapeutic signals from reaching treatment electrodes.

    Product
    48" Lead Wires, Replacement Part Number: 1067724-4
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1626-2024·2024-05-01

    Hip implant acetabular shell deburring defect triggers manufacturer recall

    The TRIDENTII HEMI CLUSTER58F hip implant acetabular shell may have excessive deburring creating a smooth edge. Howmedica Osteonics Corp. is recalling affected units.

    Product
    TRIDENTII HEMI CLUSTER58F- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-58F
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1629-2024·2024-05-01

    Hip replacement acetabular shell recalled for excessive deburring

    Howmedica Osteonics is recalling TRIDENTII PSL CLUSTER50D acetabular shells for hip replacements due to excessive deburring resulting in smooth edges on the shell.

    Product
    TRIDENTII PSL CLUSTER50D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-50D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1637-2024·2024-05-01

    Medical diagnostic test kits recalled due to misaligned results window

    Quidel InflammaDry MMP-9 test kits are recalled because the test results window is misaligned. Positive results may be hidden from view, potentially causing false negative readings.

    Product
    QUIDEL InflammaDry MMP-9 Test, REF: PRS-ID-20, 20 Tests
    Category
    Medical Device
    Distribution
    44 states
  • HighFDA (Devices)·Z-1604-2024·2024-05-01

    Redux Electrolyte Creme Recalled for Low Viscosity Defect

    Parker Laboratories is recalling Redux Electrolyte Creme, a highly conductive medical electrolyte product, due to demonstrated low viscosity.

    Product
    Redux Electrolyte Creme, Product Ref. 66-04. Highly conductive electrolyte creme.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1627-2024·2024-05-01

    Hip Implant Acetabular Shell May Have Excessive Deburring Manufacturing Defect

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER66H hip implants because the acetabular shell may have excessive deburring, creating a smooth surface on the edge of the shell.

    Product
    TRIDENTII HEMI CLUSTER66H- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-66H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1621-2024·2024-05-01

    Hip implant acetabular shell manufacturing defect recall affects patients

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER44B hip implants due to excessive deburring on the acetabular shell edge. The recalled lot was distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER44B- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-44B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1601-2024·2024-05-01

    Diagnostic Ultrasound System Displays Incorrect Cardiac Values During Measurement Export

    ACUSON Maple ultrasound systems display the last cardiac measurement value instead of the configured minimum or maximum, potentially causing patient misdiagnosis during cardiac assessment.

    Product
    ACUSON Maple Diagnostic Ultrasound System, REF: 11711750, ACUSON Maple Select, REF: 11711779, running software version VA10A
    Category
    Medical Device
    Distribution
    Distributed nationwide