The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7226–7250 of 39968

  • SevereFDA (Devices)·Z-1640-2024·2024-05-22

    Expo 5F Selective Angiographic Catheters recalled due to material delamination

    Boston Scientific Corporation is recalling Expo 5F Selective Angiographic Catheters in certain batches due to polyurethane layer delamination that prevents guidewire advancement. The inner lining material may detach, making the catheters unsafe to use.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FR5 (SGL), REF H74908526031; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1641-2024·2024-05-22

    Boston Scientific Cardiac Catheters Recalled Due to Guidewire Advancement Failure

    Boston Scientific is recalling Expo 5F Selective Angiographic Catheters due to polyurethane delamination and material detachment that may prevent guidewire advancement. The recall affects 15,079 catheters distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FR5 (5PK), REF H74908526032; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1675-2024·2024-05-22

    FDA Recalls Boston Scientific Expo 5F Cardiac Catheters Due to Delamination

    Boston Scientific is recalling 8,575 Expo 5F Selective Angiographic Catheters due to polyurethane delamination that prevents guidewire advancement. The FDA Class I recall affects devices distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO WRP (5PK), REF H74908526512; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1662-2024·2024-05-22

    Cardiac Catheters Recalled for Material Delamination Risk

    Boston Scientific is recalling Expo 5F Selective Angiographic Catheters worldwide due to polyurethane delamination and material detachment that prevents guidewire advancement.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FL6 (5PK), REF H74908526252; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1661-2024·2024-05-22

    Expo Cardiac Catheters Recalled Due to Polyurethane Delamination and Material Detachment

    Boston Scientific's Expo 5F Selective Angiographic Catheters are being recalled worldwide because the polyurethane layer is delaminating and detaching from the inner lining, preventing the guidewire from advancing through the device.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO TIG4 (5PK), REF H749085262502; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1673-2024·2024-05-22

    Boston Scientific Cardiac Catheters Recalled for Inner Lining Delamination

    Boston Scientific is recalling certain Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment in the inner lining, which can prevent guidewire advancement.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO MULTIPACK 145 (5PKX3), REF H749085265022; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1656-2024·2024-05-22

    Selective Angiographic Catheters Recalled Due to Material Delamination

    Boston Scientific recalls Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment in the catheter lining, which may prevent guidewire advancement during medical procedures.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FR4 125CM (5PK), REF H749085262252; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1678-2024·2024-05-22

    Cardiac Catheters Recalled Due to Polyurethane Delamination and Guidewire Advancement Failure

    Boston Scientific is recalling certain Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment, which may prevent proper guidewire advancement during cardiac procedures.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO CLS3.5 (5PK), REF H74908526574A2; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1667-2024·2024-05-22

    Expo 5F Angiographic Catheters Recalled for Guidewire Advancement Failure

    Boston Scientific is recalling certain batches of Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment that prevents guidewire advancement through the device.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO MULTIPACK 145 (SGL), REF H749085263011; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1669-2024·2024-05-22

    Expo 5F Selective Angiographic Cardiac Catheters: Guidewire Advancement Failure Risk

    Boston Scientific is recalling certain batches of Expo 5F Selective Angiographic Cardiac Catheters due to polyurethane delamination that prevents guidewire advancement. The recall affects 15,270 units distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO MULTIPACK 155 (5PKX3), REF H749085263022; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1660-2024·2024-05-22

    Expo 5F Cardiac Catheters Recalled for Polyurethane Delamination and Guidewire Advancement Failure

    Boston Scientific recalls Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment. The defect prevents guidewire advancement through 1065 affected devices distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO IM 125CM (5PK), REF H749085262402; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1676-2024·2024-05-22

    Expo 5F Catheters Recalled for Guidewire Advancement Failure

    Boston Scientific is recalling Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment that can prevent guidewire advancement. The issue affects 440 catheters distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO CLS2.5 (5PK), REF H74908526572A2; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1649-2024·2024-05-22

    Cardiac Catheters Recalled Due to Material Delamination and Guidewire Failure

    Boston Scientific is recalling Expo 5F cardiac catheters due to material delamination in the inner lining that prevents guidewire advancement. The defect affects 25,617 units distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO IM (5PK), REF H749085262012; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1679-2024·2024-05-22

    Boston Scientific Expo 5F Catheters recalled due to material delamination defect

    Boston Scientific is recalling Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment that can prevent guidewire advancement during cardiac procedures.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO CLS4 (5PK), REF H74908526575A2; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1643-2024·2024-05-22

    Cardiac catheters recalled due to polyurethane layer delamination defects

    Boston Scientific is recalling Expo 5F Selective Angiographic Catheters due to polyurethane layer defects that prevent proper guidewire insertion. Affected devices may experience material detachment in the catheter lining.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FR4 MOD (5PK), REF H74908526052; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1638-2024·2024-05-22

    Expo 5F Selective Angiographic Catheters Recalled for Material Delamination

    Boston Scientific is recalling Expo 5F catheters due to polyurethane delamination and material detachment preventing guidewire advancement. The recall affects approximately 16,797 catheters distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FR3.5 (5PK), REF H74908526012; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1677-2024·2024-05-22

    Cardiac Catheters Recalled Due to Defective Polyurethane Layer

    Boston Scientific recalls 1,015 Expo 5F selective angiographic catheters due to polyurethane layer delamination that prevents guidewire advancement. The defect affects multiple batches distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO CLS3 (5PK), REF H74908526573A2; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1650-2024·2024-05-22

    Expo 5F Selective Angiographic Catheters Recalled for Material Delamination

    Boston Scientific is recalling certain batches of Expo 5F Selective Angiographic Catheters due to polyurethane delamination and material detachment in the catheter's inner lining, which prevents proper advancement of the guidewire.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO IMT (5PK), REF H749085262022; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1659-2024·2024-05-22

    Expo selective angiographic cardiac catheters recalled for guidewire advancement failure

    Boston Scientific is recalling Expo 5F selective angiographic catheters due to polyurethane layer delamination and material detachment that prevents guidewire advancement through the device.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FL5 125CM (5PK), REF H749085262352; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1835-2024·2024-05-22

    Cardinal Health Curity Adhesive Bandages Recalled for Latex Contamination

    Cardinal Health is recalling Curity Flexible Adhesive Bandages (Model 44102, Lot #A14722) due to potential contamination with latex adhesive residual. The hypoallergenic product was distributed nationwide to approximately 2,000 packages.

    Product
    CardinalHealth Curity Flexible Adhesive Bandage X-Large 2 x 3.75 in. (5.1 x 9.5 cm), Model 44102, Sterile, Hypoallergenic.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1834-2024·2024-05-22

    Reagent Test Strips for Urinalysis Recalled Due to Missing Leukocytes Pad

    Macherey Nagel urinalysis test strips are recalled due to a missing leukocytes test pad on some packages, potentially resulting in false negative results for urinary tract infections and renal inflammation. Affected lot: 65402.

    Product
    Reagent Test Strips for Blood, Urobilinogen, Bilirubin, Protein, Nitrite, Ketones, Ascorbic Acid, Glucose, pH, Specific Gravity and Leucocytes in Urine by the Dip and Read Technique.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1791-2024·2024-05-22

    TriMed Threaded IM Nail System Recalled for Driver-Socket Defect

    TriMed Inc. is recalling 142 units of Threaded IM Nails with an out-of-specification driver-socket that could prevent proper surgical nail fixation and torque application.

    Product
    TriMed, Threaded IM Nail 3.6mm, 60mm, TI, Ref: IMN3.6-60 T, Non Sterile, MD, Rx Only TriMed, Threaded IM Nail 3.6mm, 65mm, TI, Ref: IMN3.6-65 T, Non Sterile, MD, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1800-2024·2024-05-22

    Medtronic Aortic Root Cannulae and Cardioplegia Needles Recalled for Unsealed Sterile Packing

    Medtronic is recalling aortic root cannulae and cardioplegia needles used in cardiac surgery due to potential unsealed sterile packaging. Approximately 2,622 units were distributed worldwide.

    Product
    Medtronic Aortic Root Cannulae and Cardioplegia Needles: a) DLP¿ 9 Ga (11 Fr) Aortic Root Cannula, Model Number 24009; b) DLP¿ 16 Ga (5 Fr) Cardioplegia Needle Neonatal 0.64 cm (1/4 in) Tip Length, Model Number 11316; c) M+AR" 14 Ga (7 Fr) Aortic Root Cannula with Flow-
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1820-2024·2024-05-22

    HeartSine Public Access Defibrillators Recalled for Voice Prompt Manufacturing Defect

    Certain HeartSine PAD defibrillators may fail to deliver voice prompts during emergency use due to a manufacturing defect, potentially delaying therapy. Visual instructions remain available.

    Product
    HeartSine samaritan PAD (Public Access Defibrillator), Type: SAM 350P, SAM 360P, SAM 450P
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1802-2024·2024-05-22

    Medtronic Disposable Pressure Display Sets recalled for unsealed sterile packaging

    Medtronic Perfusion Systems recalls 1,624 Disposable Pressure Display Sets (Models 61000 and 62000) distributed worldwide due to potential for unsealed sterile packing. No illnesses or injuries have been reported.

    Product
    Medtronic Disposable Pressure Display Sets: a) DLP¿ 114.3 cm (45 in), Model Number 61000; b) DLP¿ 114.3 cm (45 in), Model Number 62000
    Category
    Medical Device
    Distribution
    0 states