The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

5601–5625 of 27364

  • HighFDA (Devices)·Z-1631-2024·2024-05-01

    Hip replacement acetabular shell recalled for excessive deburring

    Howmedica Osteonics is recalling TRIDENTII PSL CLUSTER58F hip replacement acetabular shells due to excessive deburring. The manufacturing defect affects units distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER58F-Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-58F
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1628-2024·2024-05-01

    Hip implant recalled for acetabular shell deburring defect

    Howmedica Osteonics Corp. is recalling TRIDENTII PSL CLUSTER48D hip implants (Lot 16311453) due to excessive deburring on the acetabular shell edge, a manufacturing defect.

    Product
    TRIDENTII PSL CLUSTER48D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-48D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1619-2024·2024-05-01

    Lead Wire Replacement Parts Recalled for Sheath Damage and Treatment Signal Loss

    EBI, LLC is recalling 594 units of 48-inch lead wire replacement parts (part number 1067724-4) due to sheath damage that prevents therapeutic signals from reaching treatment electrodes.

    Product
    48" Lead Wires, Replacement Part Number: 1067724-4
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1618-2024·2024-05-01

    Replacement Lead Wires Recalled for Risk of Treatment Delivery Failure

    EBI, LLC recalls 829 replacement lead wire assemblies (Part 1067724-2) distributed nationwide since May 1, 2023. Damaged wire sheaths may prevent therapeutic treatment signals from reaching electrodes, potentially delaying treatment.

    Product
    20" Lead Wires, Replacement Part Number: 1067724-2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1616-2024·2024-05-01

    Spine Fusion Stimulator Recalled for Damaged Lead Wire Sheath

    The Biomet SpinalPak Spine Fusion Stimulator System is recalled for potential lead wire sheath damage that may prevent delivery of the therapeutic treatment signal. Devices distributed nationwide since May 2023 are affected.

    Product
    Biomet SpinalPak Non-invasive Spine Fusion Stimulator System- Indicated for the treatment of an established nonunion acquired secondary to trauma, excluding vertebrae and all flat bones, Part Number: 1067716
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1688-2024·2024-05-01

    PIEZON Bottle May Disassemble Under Pressure During Dental Use

    FDA recalls PIEZON Bottle (Model EG-111) dental treatment bottles because certain units may separate into two parts when pressurized during treatment or storage. No injuries have been reported.

    Product
    Brand Name: PIEZON Bottle Product Name: PIEZON Bottle Model/Catalog Number: EG-111 Software Version: N/A Product Description: These bottles are sold empty and are filled by the user with water - in some cases small quantities of disinfectant solutions - for dental treatments.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0590-2024·2024-05-01

    Tissue Processor Recall: HistoCore PEGASUS May Produce Damaged Specimens

    Leica is recalling 98 HistoCore PEGASUS automated tissue processors due to a protocol configuration error that can produce poorly processed or damaged biopsy specimens.

    Product
    Leica HistoCore PEGASUS (PROCESSOR, TISSUE, AUTOMATED)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1620-2024·2024-05-01

    Pedicle Screw Heads Recalled Due to Cross-Threading Risk During Surgery

    SeaSpine's Mariner RDX MIS pedicle screw heads may have partial threading that causes cross-threading at the screw head interface during implant installation. Affected units distributed in CA, FL, CO, and TX.

    Product
    Mariner RDX MIS Polyaxial Head, REF: MX1-001010, part of Mariner RDX MIS Alpha Instruments and Implants, REF: AMRDXMIS, which are pedicle screw systems.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1690-2024·2024-05-01

    Philips Patient Information Center iX UPS devices recalled for potential power failure

    Philips is recalling certain Patient Information Center iX Uninterruptable Power Supply devices due to potential power supply failures that could cause the monitoring system to shut down, risking delays in detecting patient condition changes.

    Product
    Philips Patient Information Center (PIC) iX Uninterruptable Power Supply (UPS): 1. APC (Schneider Electric IT Corporation) 120V Uninterruptable Power Supply Model: SCL500RM1U 2. APC (Schneider Electric IT Corporation) 230V Uninterruptable Power Supply Model: SCL500R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1608-2024·2024-05-01

    NexGen CR-Flex Femoral Components Recalled for Bonding Defect

    Zimmer is recalling 5,546 units of NexGen CR-Flex Femoral Components due to a manufacturing defect where the fiber metal pad fails to bond properly to the substrate. Patients with these implants should contact their healthcare provider.

    Product
    NexGen CR-Flex Femoral Component, Size E and Size E Minus (E-). Component of the NexGen CR-Flex Porous Femur System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1602-2024·2024-05-01

    Abbott Alinity m System camera generates error with certain tubes

    Abbott Molecular is recalling 1,012 Alinity m System units due to a camera detection issue that generates an error message when certain third-party transport medium tubes lack a sample rack retention bar.

    Product
    Alinity m System, Part Number: 08N53-002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1635-2024·2024-05-01

    Palindrome Precision H Chronic Catheter Kit may lack labeled heparin coating

    Covidien is recalling 878 units of Palindrome Precision H Chronic Catheter Kits that may lack the heparin anticoagulant coating indicated on the label, potentially reducing clot prevention during hemodialysis.

    Product
    Palindrome Precision H Chronic Catheter Kit 14.5 Fr/Ch (4.8mm) x 23 cm (Symmetrical Tip, Heparin Coating and Tal VenaTrac Stylet- Intended for acute and chronic hemodialysis, apheresis, and infusion. Model Number (CFN): 8888145044CP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1630-2024·2024-05-01

    Hip prosthesis shells recalled for manufacturing deburring defect

    Howmedica Osteonics Corp. is recalling TRIDENTII PSL CLUSTER52E hip prostheses with excessive deburring on the acetabular shell edge, which could affect implant stability. Three units were distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER52E- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-52E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1601-2024·2024-05-01

    Diagnostic Ultrasound System Displays Incorrect Cardiac Values During Measurement Export

    ACUSON Maple ultrasound systems display the last cardiac measurement value instead of the configured minimum or maximum, potentially causing patient misdiagnosis during cardiac assessment.

    Product
    ACUSON Maple Diagnostic Ultrasound System, REF: 11711750, ACUSON Maple Select, REF: 11711779, running software version VA10A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1617-2024·2024-05-01

    Biomet OrthoPak Bone Growth Stimulator System Recalled Due to Lead Wire Damage

    The Biomet OrthoPak Bone Growth Stimulator System is being recalled due to potential lead wire sheath damage that could prevent therapeutic signal delivery and delay patient treatment nationwide.

    Product
    Biomet OrthoPak Non-invasive Bone Growth Stimulator System-Indicated for the treatment of an established nonunion acquired secondary to trauma, excluding vertebrae and all flat bones. Part Number: 1067718
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1636-2024·2024-05-01

    Quidel InflammaDry MMP-9 Test: Misaligned Results Window May Cause False Negatives

    Quidel Corporation is recalling 104,300 units of InflammaDry MMP-9 diagnostic tests due to misalignment of the test results window. Positive results may be hidden and not visible, potentially leading to false negative readings.

    Product
    QUIDEL InflammaDry MMP-9 Test, REF: PRS-ID-20-U, 20 Tests
    Category
    Medical Device
    Distribution
    44 states
  • HighFDA (Devices)·Z-1621-2024·2024-05-01

    Hip implant acetabular shell manufacturing defect recall affects patients

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER44B hip implants due to excessive deburring on the acetabular shell edge. The recalled lot was distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER44B- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-44B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1606-2024·2024-05-01

    Alcon Custom Paks Surgical Procedure Packs recalled for cannula defects

    Alcon is recalling Custom Paks Surgical Procedure Packs containing Oasis 27Ga Chang Hydrodissection Cannulas due to complaints of particulates, residue, occlusions, and bent tips in sterile cannulas used in ophthalmic surgery.

    Product
    Various Alcon Custom Paks Surgical Procedure Pack containing Oasis 27Ga Chang Hydrodissection Cannulas. These Custom Paks are surgical procedure packs used by ophthalmic surgeons in a variety of ophthalmic surgeries. The Custom Pak is a collection of various ophthalmic surgical
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1615-2024·2024-05-01

    LightStrike Blackout Curtains Recalled Due to Inadequate UV and Ozone Protection

    XENEX LightStrike Blackout Curtains are recalled due to inadequate protection against UV and ozone exposure. Bystanders in rooms during device operation may experience temporary skin reddening, eye irritation, nausea, and headache.

    Product
    LightStrike Blackout Curtains, Part numbers; 610-00008, 610-00009, 610-00019, 610-00020, and 610-00024, used with the LightStrike Germ-Zapping Robots Models: PXUV4D, PXUV5D, LSMUV6-FT, or LSMUV6-SL, for whole room microbial reduction.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1686-2024·2024-05-01

    Cleaner Bottles May Disassemble Under Pressure During Treatment

    EMS CLEANER BOTTLES (Model EG-1000) for dental prophylaxis systems may disassemble under pressure during treatment or storage. FDA Class II recall; no injuries reported.

    Product
    Brand Name: CLEANER BOTTLE Product Name: CLEANER BOTTLE Model/Catalog Number: EG-1000 Software Version: N/A Product Description: CLEANER bottles used with EMS AIRFLOW PROPHYLAXIS MASTER / EMS AIRFLOW ONE devices to clean the water lines. The bottle is placed on the device du
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1502-2024·2024-04-24

    Philips Trilogy EV300 Ventilator False Power Alarm Defect Recall

    Philips is recalling 56,012 Trilogy EV300 ventilators due to a software defect that can trigger a false Battery Depleted or Loss of Power alarm despite adequate power, risking sudden loss of ventilation.

    Product
    Trilogy EV300, all software versions except 1.05.06.00. Ventilator for pediatric and adult patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1520-2024·2024-04-24

    SonarMed Airway Monitoring Sensor Fails to Detect Partial Obstruction

    SonarMed Inc is recalling 690 units of the AW-S030 NEO SONARMED SENSOR because the sensor fails to detect partial airway obstruction. The devices were distributed across 20 US states.

    Product
    AW-S030 NEO SONARMED SENSOR 3.0MM. Used in conjunction with SonarMed Monitor for airway monitoring.
    Category
    Medical Device
    Distribution
    19 states
  • SevereFDA (Devices)·Z-1499-2024·2024-04-24

    Philips Respironics Aeris EVO Ventilators Recalled for Loss of Ventilation Risk

    Philips Respironics is recalling Aeris EVO ventilators due to a software defect that may cause false battery or power alarms while the device retains adequate power, risking sudden loss of ventilation in pediatric and adult patients. Approximately 775 units are affected.

    Product
    Aeris EVO, all software versions except 1.05.06.00. Ventilator for pediatric and adult patients. (sold outside US)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1504-2024·2024-04-24

    Trilogy Evo Ventilator Recall Due to Potential Loss of Ventilation

    Philips Respironics is recalling the Trilogy Evo ventilator (76,713 units) because it may suddenly stop ventilating when a false Battery Depleted or Loss of Power alarm triggers despite sufficient power available.

    Product
    Trilogy Evo, all software versions except 1.05.06.00. Ventilator for pediatric and adult patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1397-2024·2024-04-24

    Elekta Disposable Biopsy Needles Recalled for Microscopic Internal Debris

    Elekta recalled disposable biopsy needles from batch 837838839 that may contain microscopic stainless steel debris inside. The sterility of the needles has not been affected, and this issue has been reported from only one site.

    Product
    Elekta Disposable Biopsy Needle Kit for Leksell Stereotactic System, REF 911933, 2.1mm Diameter / 14 Gauge, containing 6 inner boxes labeled REF 911761, Disposable Biopsy Needle Kit for Leksell Stereotactic System. Each inner box of REF 911761 contains a Tyvek bag labeled REF 91
    Category
    Medical Device
    Distribution
    0 states