The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

13176–13200 of 13802

  • HighFDA (Devices)·Z-2308-2021·2021-08-25

    Hitachi L43K intraoperative probe recall: screw cover may detach during sterilization

    Hitachi Healthcare is recalling 120 Model L43K intraoperative probes because the screw cover at the probe tip may fall off after cleaning and sterilization. Facilities should inspect probes before and after sterilization and before and after each surgical use.

    Product
    Model L43K Intraoperative Probe-For the diagnostic ultrasound evaluation during robotic/non-robotic intra-operative and laparoscopic procedures
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2316-2021·2021-08-25

    CT system software error recommends excessive contrast volume

    A software defect in Philips CT imaging systems causes incorrect contrast volume calculations when patient weight units are set to pounds, resulting in increased contrast dosing recommendations. Three units with specific serial numbers are affected.

    Product
    728327 Ingenuity CT Upgrades-Computed Tomography X-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2317-2021·2021-08-25

    IQon Spectral CT System Software Error Increases Contrast Volume

    Philips IQon Spectral CT systems can recommend excessive contrast volume when patient weight is set to pounds due to a SynchRight software calculation error, potentially resulting in patient overdose.

    Product
    728332 IQon Spectral CT-Computed Tomography X-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2294-2021·2021-08-25

    Soltive Laser Systems recalled for thermal burn injury risk during stone treatment

    Olympus is recalling Soltive laser systems used in urological surgery because exceeding recommended power settings can cause thermal burns to tissue during kidney stone treatment.

    Product
    Soltive Premium Super Pulsed Laser System (TFL-PLS) & Pro Super Pulsed Laser System (TFL-SLS). Intended for incision, excision, resection, ablation, coagulation, hemostasis, and vaporization of soft tissue, with or without an endoscope, in urology, lithotripsy, gastroenterologica
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2328-2021·2021-08-25

    TheraSphere Administration Set may leak or loosen at catheter connection

    Boston Scientific is recalling TheraSphere Administration Sets due to potential leaks and loosening at the patient catheter connection. Approximately 4,200 sets were distributed worldwide.

    Product
    TheraSphere Administration Set, REF OTT-SPE-FP-001 (990264.SPE)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2301-2021·2021-08-25

    NEO DELTA Self Safe T IV Catheters Recalled for Sterilization Failure

    NEO DELTA Self Safe T IV catheters may lack sterility due to sterilization problems. The FDA is recalling 20,000 units distributed in Florida and Minnesota.

    Product
    NEO DELTA Self Safe T, I.V. catheter of PUR a) REF 3779422 b) REF 3769522 c) REF 3708522
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2305-2021·2021-08-25

    FDA Recalls WOLF-PAK IV Catheters Due to Sterilization Problems

    Delta Med SpA is recalling WOLF-PAK Self Safe Safety IV Catheters due to sterilization defects affecting approximately 40,000 units in Florida and Minnesota.

    Product
    WOLF-PAK Self Safe Safety IV Catheter: a) REF PIVD2010W b) REF PIV2210W c) REF PIV2475W
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2287-2021·2021-08-25

    Trilogy Evo Ventilator Software Defect May Cause Pressure Increase

    Philips Respironics recalls Trilogy Evo ventilators due to software issues that may increase pressure delivery to patients. The defect affects multiple product variants worldwide.

    Product
    Trilogy Evo, Product numbers BL2110X15B, CA2110X12B, DE2110X13B, DS2110X11B, EE2110X15B, ES2110X15B, EU2110X15B, EU2110X19, FR2110X14B, GB2110X15B, IA2110X15B, IN2110X15B, IN2110X19, IT2110X21B, KR2110X15B, LA2110X15B, LD2110X23B, ND2110X15B, RDE2110X13B, UDS2110X11B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2304-2021·2021-08-25

    I.V. Catheter Recall Due to Possible Sterilization Failure

    Delta Med recalls NEO DELTA SELFSAFE PUR T I.V. catheters distributed in Florida and Minnesota due to sterilization problems. Non-sterile catheters pose infection risks.

    Product
    NEO DELTA SELFSAFE PUR T, I.V. Catheter:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2290-2021·2021-08-25

    Trilogy Evo Respiratory Device Recalled for Software Pressure Issues

    Philips Respironics has recalled Trilogy Evo Universal respiratory devices (model DS2000X11B) for software defects that increase pressure, particularly in pediatric and infant applications.

    Product
    Trilogy Evo Universal, Product number DS2000X11B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2311-2021·2021-08-25

    Cell Marque Antibody Reagents Recalled for Incorrect Expiry Date Labeling

    Cell Marque antibody reagents used in pathology are recalled for labeling an incorrect expiry date (December 31, 2023 instead of December 31, 2022). Using expired reagent may result in weak or absent staining and false negative test results.

    Product
    Cell Marque Antibodies, PSA (ER-PR8) Mouse Monoclonal Antibody, REF: 324M-15, 324M-16
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2323-2021·2021-08-25

    Cytocell DNA Diagnostic Probe Recalled for Unexpected Chromosomal Signals

    Cytocell Ltd. is recalling a DNA diagnostic probe that may produce unexpected signals at additional chromosomal locations during testing. The affected probe is an in vitro diagnostic reagent used in laboratory cytogenetic analysis.

    Product
    Cytocell LPH019-A E2A (TCF3) Breakapart Probe- In Vitro Diagnostic Analyte specific reagents (ASR's)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2295-2021·2021-08-25

    FDA Recalls DELTAVEN Safety I.V. Catheters Due to Sterilization Defect

    Delta Med SpA recalls 30,900 DELTAVEN Safety I.V. Catheters in Florida and Minnesota due to potential sterilization failures that could compromise device sterility.

    Product
    DELTAVEN Safety I.V. Catheter in Pur with closed system: a) REF 3836272 b) REF 3814272 c) REF 3845272 d) REF 3856272
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2296-2021·2021-08-25

    FDA Recalls DELTAVEN Y Safety IV Catheters Due to Sterilization Issues

    Delta Med SpA is recalling DELTAVEN Y DNL Safety IV Catheters with closed system due to sterilization problems. The recalled units may lack proper sterility and pose a risk to patients.

    Product
    DELTAVEN Y DNL Safety I.V. Catheter in Pur with closed system: a) REF 3832572 b) REF 3842572 c) REF 3821572 d) REF 3833572 e) REF 3831572 f) REF 3810572 g) REF 3852572
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2319-2021·2021-08-25

    RUSCH Slick Set Cuffed Endotracheal Tubes Recalled for Improper Cuff Inflation

    Teleflex Medical Europe Ltd. is recalling RUSCH Slick Set Cuffed Endotracheal Tubes because the cuff can inflate while the pilot balloon remains flat, potentially affecting airway pressure monitoring.

    Product
    RUSCH Slick Set Cuffed Endotracheal Tube and Stylet Set, oral/nasal, REF numbers: a) 170050 b) 170055 c) 170060 d) 170065 e) 170070 f) 170075 g) 170080 h) 170085 i) 170090 j) 170095
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2315-2021·2021-08-25

    CT5000 X-ray System Contrast Dose Calculation Error Under Pounds Setting

    Philips CT5000 X-ray systems may incorrectly calculate contrast volume doses when patient weight units are set to pounds. The software error could recommend higher-than-intended contrast volumes.

    Product
    Model 728321/728323 CT5000 Ingenuity Plus/Pro/Premium-Computed Tomography X-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2313-2021·2021-08-25

    NEO-KATH Caudal Catheter Set Recalled Due to Stylet Protrusion Risk

    Epimed International is recalling the NEO-KATH Caudal Set (REF 201-2430) because the stylet may protrude from the catheter's tip, potentially causing tissue injury. The recall affects 140 units distributed in the US and internationally.

    Product
    NEO-KATH(TM) Caudal Set, REF 201-2430, Sterile
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-2289-2021·2021-08-25

    Trilogy EV300 Ventilator Recalled for Software-Related Pressure Calibration Issues

    Philips Respironics is recalling the Trilogy EV300 ventilator due to software issues causing pressure calibration errors affecting infant and pediatric patients. The defects impact 18,936 units distributed in the United States.

    Product
    Trilogy EV300, Product numbers CA2200X12B, DS2200X11B, FX2200X15B, IN2200X15B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2322-2021·2021-08-25

    RUSCH Endotracheal Tube Cuff Inflation Malfunction Without Pilot Balloon Indication

    Teleflex recalls RUSCH endotracheal tubes because the cuff can be inflated while the pilot balloon remains flat, preventing proper monitoring of cuff pressure.

    Product
    RUSCH Endotracheal Tube oral/nasal Murphy Eye, High Volume, Low Pressure Cuff, REF numbers: a) 112082050 b) 112082055 c) 112082060 d) 112082065 e) 112082070 f) 112082075 g) 112082080 h) 112082085 i) 112082090 j) 112082095 k) 112082100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2300-2021·2021-08-25

    IV Catheters Recalled Due to Possible Missing Sterility

    Delta Med SpA is recalling NEO DELTA Self Safe 1 IV catheters due to possible missing sterility. The recall affects 5,000 units distributed in Florida and Minnesota.

    Product
    NEO DELTA Self Safe 1, I.V. Catheter with PUR REF 3708122, Lot 00A1160627 5000 units
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2288-2021·2021-08-25

    Trilogy Evo O2 Ventilator Software Issues Affecting Pressure Delivery

    Philips Respironics is recalling Trilogy Evo O2 ventilators with software issues that can increase pressure delivery. One issue affects infant/pediatric settings; another causes pressure drift during continuous use.

    Product
    Trilogy Evo O2, Product numbers DE2100X13B, DS2100X11B, EE2100X15B, ES2100X15B, EU2100X15B, FR2100X14B, FX2100X15B, IA2100X15B, IN2100X15B, IN2100X19, IT2100X21B, JP2100X16B, LA2100X15B, ND2100X15B, RDE2100X13B, SP2100X26B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2291-2021·2021-08-25

    Tornier Aequalis Pyrocarbon shoulder implants recalled for potential graphite exposure

    Tornier recalls Aequalis Pyrocarbon shoulder implants (6,631 units) due to potential patient exposure to graphite substrate material. The units were distributed across multiple U.S. states.

    Product
    The Aequalis Pyrocarbon Humeral Heads. Shoulder implant component. Sold OUS only: a) Catalog # DWH039 - Diameter 39 mm Height 14 mm Eccentric LOW (1.5) Material PyC/CoCr, b) Catalog # DWH041 - Diameter 41 m m Height 15 mm Eccentric LOW (1.5) Material PyC/CoCr, c) Catalog
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-2302-2021·2021-08-25

    I.V. Catheter Recall Due to Sterilization Failures

    Delta Med is recalling approximately 1,400 NEO DELTA SELFSAFE PUR 1 I.V. catheters (Lot 00A1160806) distributed in Florida and Minnesota due to sterilization process defects that may result in non-sterile devices.

    Product
    NEO DELTA SELFSAFE PUR 1, I.V. Catheter, REF 3718122
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2325-2021·2021-08-25

    Evexia Luxe DVT Prevention Device Recalled for Marketing Without FDA Clearance

    Ortho8, Inc. is recalling the Evexia Luxe DVT Prevention Device because it was marketed without required FDA clearance. The device is intended to prevent deep vein thrombosis.

    Product
    EVEXIA LUXE DVT PREVENTION DEVICE, Aid in the Prevention of Deep Vein Thrombosis, REF(s): EVE-11/EVE-X11, Rx Only, Not Sterile
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2292-2021·2021-08-25

    Gore Propaten Vascular Graft Pediatric Shunt Dimension Labeling Error Recall

    W L Gore & Associates is recalling Gore Propaten Vascular Grafts for pediatric shunts due to incorrect diameter labeling: grafts with 6mm inner diameter are labeled 5mm, and those with 5mm diameter are labeled 6mm.

    Product
    Gore Propaten Vascular Graft configured for Pediatric Shunt, Diameter 5 mm, Length 10 cm, Rx Only, Sterile EO, for the following Reference numbers: HPT050010 UDI: (01)00733132606320 HPT050010A UDI: (01)00733132606337
    Category
    Medical Device
    Distribution
    10 states