The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

676–700 of 39760

  • HighFDA (Devices)·Z-2401-2026·2026-06-17

    Bicarby dialysate bags carry an incorrect GTIN on the label

    Bicarby Dialysate, model RFP-400-G, is being recalled because of an error in the GTIN printed on the product, which could lead to a potassium concentration differing from the prescription.

    Product
    Bicarby Dialysate; Model number: RFP-400-G;
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2400-2026·2026-06-17

    Aluminum chloride hemostatic gel kits shipped with wrong package insert

    Advance Aluminum Chloride Gel Clear Hemostatic Gel Kits are being recalled because some units contain the package insert for Ferric Sulfate Gel, which gives different first aid instructions.

    Product
    Advance Aluminum Chloride Gel Clear Hemostatic Gel Kit, Catalog number 504600-28
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2398-2026·2026-06-17

    Siemens Dimension tacrolimus reagent cartridges may bias results positively

    Three lots of the Siemens Dimension Tacrolimus Flex reagent cartridge are being recalled because of a potential positive bias in quality control and patient sample results.

    Product
    Siemens Dimension Tacrolimus Flex Reagent Cartridge (TAC), REF DF207, SMN 10700795; enzyme immunoassay
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2362-2026·2026-06-17

    EXENT Analyser marked plates as passed without performing quality control

    An EXENT Analyser is being recalled after plates 2 and 3 were marked as passed although quality control appeared not to have been performed, despite samples being measured.

    Product
    Brand Name: EXENT Analyser Product Name: EXENT Analyser Model/Catalog Number: IE800.A Software Version: 1.0.20 Product Description: The EXENT Analyser is an automated analyser intended for the qualitative and quantitative in vitro measurement of analytes in human body fluids
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2315-2026·2026-06-17

    GE Allia IGS 5 Pulse systems pose shock risk to servicers

    Allia IGS 5 Pulse angiographic X-ray systems are being recalled because an electrical cable issue could expose service personnel to electrical shock while power is on. 121 units affected.

    Product
    Allia IGS 5 Pulse angiographic X-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2348-2026·2026-06-17

    MIC Safety 20 Fr push OTW PEG kits contain recalled lidocaine

    MIC Safety PEG Kits with ENFit Connectors, 20 Fr PUSH OTW, catalog number 8170-20, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall.

    Product
    Product Name: MIC Safety Percutaneous Endoscopic Gastrostomy PEG Kit with ENFit Connectors 20 Fr PUSH OTW Model/Catalog Number: 8170-20
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2338-2026·2026-06-17

    CORFLO Safety PEG kit 50-5320 contains recalled lidocaine injection

    CORFLO Safety PEG Kits with ENFit Connector, catalog number 50-5320, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall. 72 kits affected.

    Product
    Product Name: CORFLO* Safety PEG Kit with ENFit¿ Connector Model/Catalog Number: 50-5320
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2346-2026·2026-06-17

    MIC Safety 24 Fr pull PEG kits contain recalled lidocaine injection

    MIC Safety PEG Kits, 24 Fr PULL, catalog number 7180-24, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall. 1,006 kits affected.

    Product
    Product Name: MIC Safety Percutaneous Endoscopic Gastrostomy PEG Kit 24 Fr PULL Model/Catalog Number: 7180-24
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2326-2026·2026-06-17

    CGuard Prime 8mm carotid stent systems may resist or fail deployment

    CGuard Prime Carotid Stent Systems, 135 cm with an 8 mm x 40 mm stent, are being recalled because the delivery system may meet high resistance or fail to deploy the stent.

    Product
    Brand Name: CGuard¿ Prime Carotid Stent System, 135cm, 8mmx40mm Model/Catalog Number: CND0840
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2335-2026·2026-06-17

    CORFLO Safety PEG kit 30-6312 contains recalled lidocaine injection

    CORFLO Safety PEG Kits, catalog number 30-6312, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall. 31 kits are affected.

    Product
    Product Name: CORFLO* Safety PEG Kit Model/Catalog Number: 30-6312
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2339-2026·2026-06-17

    CORFLO Safety PEG kit 50-6312 contains recalled lidocaine injection

    CORFLO Safety PEG Kits with ENFit Connector, catalog number 50-6312, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall. 43 kits affected.

    Product
    Product Name: CORFLO* Safety PEG Kit with ENFit¿ Connector Model/Catalog Number: 50-6312
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2404-2026·2026-06-17

    Boston Scientific Clik X anchors may lack sterility assurance

    Boston Scientific Clik X Anchors, model SC-4318, are being recalled because the sterile anchors may lack sterility assurance. 43 units are affected.

    Product
    Boston Scientific Model SC-4318, Clik X Anchor REF: M365SC43180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2399-2026·2026-06-17

    Hintermann left talar implant packaging contained a right-side device

    Hintermann Series Talar Implants, Left, Size 2, are being recalled because packaging and labeling for a left implant contained a right implant device. 67 units are affected.

    Product
    Hintermann Series Talar Implant, Left, Size 2 REF 302112
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2408-2026·2026-06-17

    Halyard towel six packs shipped without validated sterilization in Iowa

    Halyard Towel Six Packs, kit code AMTS70-01, are being recalled because sealed pouches that had not undergone validated sterilization were inadvertently distributed. 224 kits affected.

    Product
    Halyard, Towel Six Pack. Kit Code: AMTS70-01.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2341-2026·2026-06-17

    MIC Safety 7170-14 push PEG kits contain recalled lidocaine injection

    MIC Safety PEG Kits, 14 Fr PUSH OTW, catalog number 7170-14, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall. 22 kits affected.

    Product
    Product Name: MIC Safety Percutaneous Endoscopic Gastrostomy PEG Kit 14 Fr PUSH OTW Model/Catalog Number: 7170-14 Product Description: Feeding Tube Kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2413-2026·2026-06-17

    Orca single use endoscope valves recalled over sticking suction buttons

    Boston Scientific is removing Orca Sterile, Single Use Air/Water and Suction Valves because of a higher than anticipated occurrence of the suction button sticking. 9,750 units affected.

    Product
    Orca Single Use Air/Water and Suction Valves, Material Number (UPN) SUV-617-50; The Orca Air/Water Valve is intended to be used to control the air/water function on an endoscope during a GI (gastrointestinal) endoscopic procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2410-2026·2026-06-17

    Halyard eye bag packs shipped without validated sterilization in Iowa

    Halyard Eye Bag Packs, kit code UIEB48-01, are being recalled because sealed pouches that had not undergone validated sterilization were inadvertently distributed. 60 kits affected.

    Product
    Halyard, Eye Bag Pack. Kit Code: UIEB48-01.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2409-2026·2026-06-17

    Halyard drape packs shipped without undergoing validated sterilization process

    Halyard Drape Packs, kit code LMDP36-01, are being recalled because sealed pouches that had not undergone validated sterilization were inadvertently distributed. 72 kits affected.

    Product
    Halyard, Drape Pack. Kit Code: LMDP36-01.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2313-2026·2026-06-17

    Plum Duo Precision IV pumps may not display soft limit alerts

    Plum Duo Precision IV Pumps are being recalled because under certain conditions the pump may not display a soft limit alert before delivery starts, potentially leading to under- or over-delivery.

    Product
    Plum Duo Precision IV Pump, 40002-0403
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2312-2026·2026-06-17

    Plum Duo infusion pumps may not display soft limit alerts

    Plum Duo Infusion Pumps are being recalled because under certain conditions the pump may not display a soft limit alert before delivery starts, potentially leading to under- or over-delivery.

    Product
    Plum Duo Infusion Pump, 40002-0401
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2324-2026·2026-06-17

    TDC VELOCE 27 gauge vitrectomy cutters may have loose outer knife

    TDC VELOCE 27G Two Dimensional Cutters are being recalled following an increase in complaints of a loose outer knife, including reports of it loosening during use.

    Product
    TDC VELOCE", 27G Two Dimensional Cutter - 20k CPM; Article Numbers: 9268.VIT27, 9311.27G01, 9311.27G02, 9311.27K01, 9311.27K02, 9311.27K03, 9627.G0101, 9627.G0201, 9311.27G01-00;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2350-2026·2026-06-17

    MIC Safety 14 Fr PEG kits contain recalled lidocaine injection

    MIC Safety PEG Kits with ENFit Connectors, 14 Fr PULL, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall for quality issues.

    Product
    Product Name: MIC Safety Percutaneous Endoscopic Gastrostomy PEG Kit with ENFit Connectors 14 Fr PULL Model/Catalog Number: 8180-14
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2344-2026·2026-06-17

    MIC Safety 14 Fr pull PEG kits contain recalled lidocaine injection

    MIC Safety PEG Kits, 14 Fr PULL, catalog number 7180-14, are being recalled because they contain lidocaine hydrochloride injection subject to a supplier recall. 208 kits affected.

    Product
    Product Name: MIC Safety Percutaneous Endoscopic Gastrostomy PEG Kit 14 Fr PULL Model/Catalog Number: 7180-14
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2317-2026·2026-06-17

    GE Allia IGS Pulse systems pose shock risk to service personnel

    Allia IGS Pulse angiographic X-ray systems are being recalled because an electrical cable issue could expose service personnel to electrical shock while power is on.

    Product
    Allia IGS Pulse angiographic X-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2407-2026·2026-06-17

    Halyard pain packs shipped without validated sterilization in Iowa

    Halyard Pain Packs, kit code AMPK48-01, are being recalled because sealed pouches that had not undergone validated sterilization were inadvertently distributed. 120 kits affected.

    Product
    Halyard, Pain Pack. Kit Code: AMPK48-01.
    Category
    Medical Device
    Distribution
    Distributed nationwide