The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6601–6625 of 13652

  • HighFDA (Devices)·Z-1748-2024·2024-05-08

    Radiation Therapy Planning System May Calculate Skin Surface Distance Incorrectly

    RayStation radiation therapy planning software versions 11.0.0.951, 11.0.1.29, 11.0.3.116, and 11.0.4.15 may calculate skin surface distance (SSD) values incorrectly, potentially affecting dose calculations. Affected software has been distributed worldwide.

    Product
    RayStation 11.0.0.951, 11.0.1.29, 11.0.3.116 & 11.0.4.15. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1714-2024·2024-05-08

    Zimmer Locking Plate System recalled due to thread mating defect

    Zimmer is recalling the ZPLP Distal Lateral Fibular Plate due to a thread form defect in the locking holes. Locking screws may not properly mate with the plate, potentially causing surgical delay or loss of fixation.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 16 Holes, 236 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-16
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1716-2024·2024-05-08

    Zimmer Locking Plate System Recalls Distal Fibular Plates Due to Thread Defect

    Zimmer recalls distal fibular plates with defective locking holes that may prevent proper screw fixation during orthopedic surgery, potentially requiring additional intervention.

    Product
    ZPLP(Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Left, 6 Holes, 106 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1706-2024·2024-05-08

    Zirconium oxide dental restoration blocks may develop cracks during sintering

    IVOCLAR VIVADENT recalls 12,525 zirconium oxide blocks for dental restorations after defective units may develop cracks during sintering, potentially causing restoration fractures.

    Product
    IPS e.max ZirCAD CER/in. Prime A3 C17/5 -A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth Article Number: 758439
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1717-2024·2024-05-08

    Zimmer Periarticular Locking Plate recalled for improper screw mating defect

    Zimmer, Inc. is recalling the ZPLP Distal Lateral Fibular Plate due to a thread form defect that may prevent locking screws from properly mating with the plate, potentially causing surgical delays or loss of fixation.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Left, 8 Holes, 132 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1745-2024·2024-05-08

    Radiation therapy planning system dose calculation error

    RayStation versions 9.1.0.933 and 9.2.0.483 may incorrectly calculate dose parameters. 11 units of this radiation therapy treatment planning software were distributed worldwide.

    Product
    RayStation 9.1.0.933 and 9.2.0.483. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1741-2024·2024-05-08

    RayStation 7.0.0.19 radiation therapy planning software recalled for dose calculation error

    RayStation 7.0.0.19, a radiation therapy treatment planning system, is being recalled due to potential source-to-surface distance (SSD) calculation errors that could affect radiation dose accuracy. The recall affects 14 units distributed worldwide.

    Product
    RayStation 7.0.0.19. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1729-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate Recall Due to Locking Thread Defect

    Zimmer recalls certain ZPLP Distal Lateral Fibular Plates due to thread form defects in locking holes that may prevent proper screw fixation. Affected devices may lose fixation, potentially delaying surgery or requiring additional intervention.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 10 Holes, 158 MM, Nonsterile-Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1712-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate Locking Screw Defect

    Zimmer's Periarticular Locking Plate may have defective locking holes that prevent screws from properly locking, risking loss of bone fixation and requiring additional surgery.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 10 Holes, 158 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1711-2024·2024-05-08

    Zimmer Periarticular Locking Plate threading defect may compromise surgical fixation

    Zimmer's Periarticular Locking Plate System may have defective threads in locking holes, preventing secure screw mating. The defect could result in loss of surgical stability and require additional surgery.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 8 Holes, 132 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1715-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate may fail to lock properly

    Zimmer orthopedic plates may have thread defects preventing locking screws from properly mating, potentially resulting in loss of fixation and need for additional surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 4 Holes, 80 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 7-2357-018-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1747-2024·2024-05-08

    Radiation therapy planning system may calculate patient doses too high

    RayStation versions 10.1.0.613 and 10.1.1.54 may calculate radiation doses higher than intended. Eighteen units have been distributed worldwide to medical facilities.

    Product
    RayStation 10.1.0.613 and 10.1.1.54. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1724-2024·2024-05-08

    Zimmer ZPLP Fibular Plate May Fail to Lock Properly During Surgery

    The ZPLP Distal Lateral Fibular Plate may have a thread defect preventing screws from locking properly, potentially compromising surgical fixation and requiring further intervention.

    Product
    ZPLP Distal Lateral Fibular Plate, Right, 8 Holes, 132 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-017-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1754-2024·2024-05-08

    Battery Mobile X-ray Units Recalled for Anti-Fall System Interference

    SEDECAL SA is recalling 636 Battery Mobile X-ray Unit EASY MOVING models worldwide due to potential interference with the anti-fall system.

    Product
    Battery Mobile X-ray Unit EASY MOVING Model with telescopic column 3.1, model numbers: a. SM-20HF-Batt; b. SM-32HF-Batt; c. SM-40HF-Batt; d. SM-50HF-Batt; e. SM-40-HF-B-D-VIR; f. SM-20HF-B-D-KM (AeroDR X30); g. SM-32-HF-B-D-KM (AeroDR X30); h. SM-40HF-B-D-KM (A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1718-2024·2024-05-08

    Zimmer Periarticular Locking Plate System recalled due to faulty screw threads

    Zimmer recalls Periarticular Locking Plate System devices due to thread defects that may prevent proper screw locking and cause surgical delay or loss of fixation.

    Product
    ZPLP(Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Left, 10 Holes, 158 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1709-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate may fail to lock screws securely

    Zimmer's Distal Lateral Fibular Plate has threading defects that may prevent screws from locking properly. The defect could go unnoticed during surgery and cause loss of fixation.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 4 Holes, 80 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1713-2024·2024-05-08

    Zimmer Periarticular Locking Plate screw-mating defect risks surgical fixation loss

    Zimmer's Periarticular Locking Plate System has a thread defect that may prevent proper screw locking, potentially causing loss of surgical fixation. Affected units distributed worldwide.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 12 Holes, 184 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-12
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1704-2024·2024-05-08

    Zirconium oxide dental blocks recalled due to cracking risk

    IVOCLAR VIVADENT AG is recalling 7,445 units of IPS e.max ZirCAD CER/in. Prime zirconium oxide blocks because they may crack during sintering, potentially causing dental restorations to fracture in patients' mouths.

    Product
    IPS e.max ZirCAD CER/in. Prime A1 C17/5 - A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth. Article Number: 758437
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1734-2024·2024-05-08

    Galaxy System Wired Controller Recalled for Unintended Scope Motion

    Noah Medical recalls 17 Galaxy System wired controllers (Model GAL-019) due to calibration misalignment that may cause unintended scope motion during bronchoscopic procedures.

    Product
    Galaxy System REF GAL-001 (specifically GAL-019, Wired Controller) The Galaxy System and its accessories are intended to provide bronchoscopic visualization of and access to patient airways for diagnostic and therapeutic procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1753-2024·2024-05-08

    Hip Cup Removal Instrument Recalled Due to Wrong Blade Assembly

    Innomed is recalling the Cup Removal Starter Instrument due to a manufacturing error where the finisher blade was affixed instead of the starter blade. The wrong blade could compromise surgical performance during hip replacement procedures.

    Product
    INNOMED CUP REMOVAL STARTER INSTRUMENT, REF 520054, Hip cutter blade cup
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-1744-2024·2024-05-08

    Radiation Therapy Planning System May Report Dose Values Too High

    RayStation radiation therapy planning software versions 9.0.0.113 and 9.0.1.142 may report dose values that are higher than actual. The Class II recall affects 63 units distributed worldwide.

    Product
    RayStation 9.0.0.113 and 9.0.1.142. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1705-2024·2024-05-08

    Zirconium oxide dental blocks recalled due to cracking and fracture risk

    IVOCLAR VIVADENT is recalling IPS e.max ZirCAD zirconium oxide blocks nationwide because they may develop cracks after sintering that could cause dental restorations to fracture in patients' mouths.

    Product
    IPS e.max ZirCAD CER/in. Prime A2 C17/5 -A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth. Article Number: 758438
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1727-2024·2024-05-08

    Zimmer Fibular Plate Recall: Defective Locking Hole Threading

    Zimmer, Inc. is recalling ZPLP Distal Lateral Fibular Plates due to defective threading in the locking holes. The screws may not properly engage with the plate, potentially causing surgical delays or loss of bone fixation.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 6 Holes, 106 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1698-2024·2024-05-08

    Lumbar Interbody Fusion Curette Recalled for Potential Blade Shearing

    Advanced Research Medical is recalling 1,150 units of its Lumbar Interbody Fusion System Flexible Curette Loop Blade because the disposable blade may shear during surgery, potentially leaving fragments within the shaft assembly. No injuries have been reported.

    Product
    ADVANCED RESEARCH MEDICAL Lumbar Interbody Fusion System (OLLIF), Flexible Curette Loop Blade, Part # 01-06-4; treatment of degenerative disc disease
    Category
    Medical Device
    Distribution
    Distributed nationwide