Customed Recalls Open Heart Surgical Trays Due to Packaging Integrity Concerns
Customed, Inc. is recalling Open Heart Tray surgical packs because packaging integrity may be compromised, potentially leading to product contamination or loss of sterility.
The agency’s classification
FDA (Devices): Class I
Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The source text explicitly states the agency classification is Class I. Per the rubric, if the agency's own classification is FDA Class I, the score must never go below 4. The potential for loss of sterility in surgical instruments represents a significant risk of injury.
Plain-English summary
Customed, Inc. is recalling Open Heart Tray surgical packs (Product code 900-170) due to a potential compromise in packaging integrity. The recall involves 45 lots and 1,292 units. The affected products are EO sterilized surgical convenient packs packaged into polyester/polyethylene breather bags with Tyvek double vents.
The recall was initiated because the company determined that packaging integrity may be compromised on different catalog numbers. This defect could result in product contamination or a loss of sterility condition, which poses a risk of injury to patients. The agency has classified this recall as Class I.
The affected products were distributed worldwide, including nationwide in the United States (specifically noting Florida, Puerto Rico, and the US Virgin Islands) and in the countries of Tortola, Trinidad, Dominican Republic, Costa Rica, and Mexico. Consumers and healthcare facilities should stop using the affected lots and contact Customed, Inc. for instructions on return or replacement.
The recalled product
- Product
- OPEN HEART TRAY - PACK- (25) SPONGE LAP PREWASH 18" X 18" XRD L/F (1) TRAY PLATO LARGE (3) DRESSING NON ADH TELFA 8 X 3 (2) BAG GLASSINE PLAIN (2) YANKAUER SUCTION TUBE WITHOUT VENT LIF (1) COVER TABLE REINFORCED 50" X 90" LIF (1) NEEDLE HYPODERMIC 27G X 'h" (4)…
- Manufacturer
- Customed, Inc
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- Product code 900-170
Distribution
Part of a larger recall action
This product is one of 233 recalled by Customed, Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 233 products in this recall →Related recalls
Same manufacturer · Customed, Inc
See all →- HighCustomed Arthroscopy Surgical Packs Recalled for Sterilization Validation Issues
FDA (Devices) · 2016-04-20
- HighCustomed Laparotomy Surgical Packs Recalled for Sterilization Validation Issues
FDA (Devices) · 2016-04-20
- HighCustomed Femoral Surgical Pack Recalled for Sterilization Validation Issues
FDA (Devices) · 2016-04-20
- HighCustomed Cystoscopy Surgical Packs Recalled for Sterilization Validation Issues
FDA (Devices) · 2016-04-20
- HighCustomed Basic Surgical Pack IV Recalled for Sterilization Validation Issues
FDA (Devices) · 2016-04-20
Same hazard · loss of sterility
See all →- ModerateIntramedullary Bone Saw Blade Assembly Recalled Due to Potential Packaging Damage
FDA (Devices) · 2026-08-12
- HighDaig Livewire Steerable Reprocessed Electrophysiology Catheter Recall
FDA (Devices) · 2026-05-20
- HighMedihoney Calcium Alginate Dressings Recalled Due to Potential Sterile Barrier Breach
FDA (Devices) · 2026-02-25
- SevereChloraPrep One-Step Applicators Recalled Due to Compromised Sterile Packaging
FDA (Drugs) · 2025-05-28
- HighProxima Drape sterile drapes recalled for potential packaging breach risk
FDA (Devices) · 2025-03-26
Similar recalls
- SevereCustomed Open Heart Tray Recalled Due to Compromised Sterility
FDA (Devices) · 2014-12-10
- SevereCustomed Open Heart Tray Recalled for Compromised Sterility and Contamination Risk
FDA (Devices) · 2014-12-10
- HighCustomed Open Heart Tray Recalled for Sterilization Validation Issues
FDA (Devices) · 2015-09-09
- SevereCustomed Open Heart Pack Recalled for Sterility Compromise
FDA (Devices) · 2014-12-10
- HighCustomed Open Heart Trays Recalled for Sterilization Validation Issues
FDA (Devices) · 2015-09-09
- HighCustomed Open Heart Trays Recalled for Sterilization Validation Defects
FDA (Devices) · 2015-09-09