The Recall Desk

Manufacturer

SPINEART SA

13 recalls in our database name SPINEART SA as the manufacturing or recalling firm.

What the numbers show

Total
13
Critical
0
Severe
0
Most recent
2025-08-20

Of the 13 recalls from SPINEART SA we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–13 of 13

  • HighFDA (Devices)·Z-2280-2025·2025-08-20

    Cannulated fenestrated polyaxial screws recalled because they may be incorrectly labeled

    PERLA TL MIS cannulated fenestrated polyaxial screws, model MPF-PS 55 45-S, lot 8-4266, are recalled because the screws may be incorrectly labeled.

    Product
    Brand Name: PERLA ¿ TL MIS Product Name: CANNULATED FENESTRATED POLYAXIAL SCREW Model/Catalog Number: MPF-PS 55 45-S Software Version: Not Applicable Product Description: CANNULATED FENESTRATED POLYAXIAL SCREW
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2279-2025·2025-08-20

    Polyaxial screws in lot 8-4528 recalled over possible incorrect labeling

    PERLA TL MIS cannulated fenestrated polyaxial screws, model MPF-PS 65 40-S, lot 8-4528, are recalled because the screws may be incorrectly labeled. 16 units are affected.

    Product
    Brand Name: PERLA ¿ TL MIS Product Name: CANNULATED FENESTRATED POLYAXIAL SCREW Model/Catalog Number: MPF-PS 65 40-S Software Version: Not Applicable Product Description: CANNULATED FENESTRATED POLYAXIAL SCREW Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1758-2024·2024-05-15

    Spinal Fusion Device Recall: Setscrew Insertion and Tightening Issues

    SPINEART's PERLA TL 25D spinal fusion screws are being recalled due to difficulties with setscrew insertion inside the screw head. The setscrew may not be properly tightened or may be positioned incorrectly, potentially affecting spinal stability.

    Product
    PERLA TL 25D SCREW REF: TLF-DS 45 25-S TLF-DS 45 30-S TLF-DS 45 35-S TLF-DS 45 40-S TLF-DS 45 45-S TLF-DS 55 30-S TLF-DS 55 35-S TLF-DS 55 40-S TLF-DS 55 45-S TLF-DS 65 35-S TLF-DS 65 40-S TLF-DS 65 45-S TLF-DS 65 50-S The PERLA¿ TL system is intended to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1426-2023·2023-05-03

    Lateral lumbar spine implant plate may disassemble during surgery

    SPINEART's JULIET Ti LL lateral lumbar implant plates may disassemble during preparation or implant removal, causing surgical delays. The FDA is recalling 544 affected units distributed across eight US states.

    Product
    JULIET Ti LL, LATERAL LUMBAR TI-LIFE PLATE SMALL, REF: JLT-PL 02 08-S, JLT-PL 02 10-S, JLT-PL 02 12-S, JLT-PL 02 14-S, JLT-PL 02 16-S; JULIET Ti LL, LATERAL LUMBAR TI-LIFE PLATE LARGE, REF: JLT-PL 04 08-S, JLT-PL 04 10-S, JLT-PL 04 12-S, JLT-PL 04 14-S, JLT-PL 04 16-S…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1975-2021·2021-07-07

    PERLA TL Lateral Connector Open Spinal Fusion Devices Recalled for External Label Error

    SPINEART SA is recalling 44 units of PERLA TL Lateral Connector Open spinal fusion connectors distributed in the U.S. due to external labels that incorrectly list the rod size.

    Product
    PERLA TL Lateral Connector Open - Product Usage: intended to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach. Models: PERLA TL Lateral Connector Open, 15mm PERLA TL Lateral Connector Open, 30mm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0546-2020·2019-12-04

    Spineart JULIET Ti OL Cage Recalled for Incorrect Inner Blister Label

    Spineart SA is recalling 14 JULIET Ti OL cages due to a mismatch between the inner blister pack label and the external box label.

    Product
    Intersomatic JULIET Ti OL cage. For use in orthopedic spinal procedures
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0341-2018·2018-01-24

    Spineart Recalls Tryptik 2 C-Plate Screw Due to Labeling Error

    Spineart SA is recalling 15 units of Tryptik 2 C-Plate Self Tapping Screws because the product labeling incorrectly displays a sketch of a self-drilling screw.

    Product
    TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 16 MM, REF TRY-PS-45 16-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion…
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0337-2018·2018-01-24

    Spineart Recalls Tryptik 2 C-Plate Screws Due to Labeling Error

    Spineart SA is recalling 120 units of Tryptik 2 C-Plate Self-Tapping Screws because the product labeling incorrectly displays a sketch of a self-drilling screw.

    Product
    TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 14 MM, REF TRY-PS-40 14-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion…
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0338-2018·2018-01-24

    Spineart Recalls Tryptik 2 C-Plate Screws Due to Labeling Error

    Spineart SA is recalling Tryptik 2 C-Plate self-tapping screws because the product labeling incorrectly displays a sketch of a self-drilling screw.

    Product
    TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 16 MM, REF TRY-PS-40 16-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion…
    Category
    Medical Device
    Distribution
    1 state
  • LowFDA (Devices)·Z-0340-2018·2018-01-24

    Spineart Recalls Tryptik 2 C-Plate Screws Due to Labeling Error

    Spineart SA is recalling 16 units of Tryptik 2 C-Plate Self Tapping screws distributed in California because the product labeling contains an incorrect sketch of a self-drilling screw.

    Product
    TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 14 MM, REF TRY-PS-45 14-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion…
    Category
    Medical Device
    Distribution
    1 state
  • LowFDA (Devices)·Z-0339-2018·2018-01-24

    Spineart Recalls Tryptik 2 C-Plate Screw Due to Labeling Error

    Spineart SA is recalling 9 units of Tryptik 2 C-Plate Self-Tapping Screws because the product labeling displays a sketch of a self-drilling screw instead of the correct self-tapping screw.

    Product
    TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 12 MM, REF TRY-PS-45 12-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal…
    Category
    Medical Device
    Distribution
    1 state
  • LowFDA (Devices)·Z-0342-2018·2018-01-24

    Spineart Recalls Tryptik 2 C-Plate Screws Due to Labeling Error

    Spineart SA is recalling 8 units of Tryptik 2 C-Plate Self Tapping screws because the product labeling incorrectly displays a sketch of a self-drilling screw.

    Product
    TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 18 MM, REF TRY-PS-45 18-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion…
    Category
    Medical Device
    Distribution
    1 state
  • LowFDA (Devices)·Z-0336-2018·2018-01-24

    Spineart Recalls Tryptik 2 C-Plate Screws Due to Labeling Error

    Spineart SA is recalling 54 units of Tryptik 2 C-Plate self-tapping screws because the product labeling incorrectly displays a sketch of a self-drilling screw.

    Product
    TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 12 MM, REF TRY-PS-40 12-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion…
    Category
    Medical Device
    Distribution
    1 state