The Recall Desk

Manufacturer

Remote Diagnostic Technologies Ltd.

12 recalls in our database name Remote Diagnostic Technologies Ltd. as the manufacturing or recalling firm.

What the numbers show

Total
12
Critical
0
Severe
0
Most recent
2026-01-14

Of the 12 recalls from Remote Diagnostic Technologies Ltd. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–12 of 12

  • HighFDA (Devices)·Z-1027-2026·2026-01-14

    Patient monitors recalled over unvalidated intracranial and bladder pressure measurements

    Remote Diagnostic Technologies is recalling 7,129 Philips Tempus Pro Patient Monitors because intracranial and bladder pressure measurements have not been tested or validated for accuracy.

    Product
    Philips Tempus Pro Patient Monitor, REF: 00-1004, 00-1007, 00-1004-R, 00-1007-R, 00-1024-R, 00-1026-R. USB 2-Channel IBP Module, REF: 01-2017. Used with User/Operator Manual
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2175-2025·2025-08-06

    Inseego dongle kit flash drives carry outdated patient monitor software

    Inseego USB8 4G Dongle Kits for the Tempus Pro Monitor are being recalled because the kit's USB flash drive contains outdated software that could revert the monitor and reintroduce a previous issue. 55 units affected.

    Product
    Inseego USB8 4G Dongle Kit, Part Number: 01-2298, which contains USB Flash Drive, Part Number: 43-2011. The kit is an accessory to the Tempus Pro Monitor, REF: 00-1007-R, 00-1024-R, 00-1026-R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1729-2025·2025-05-14

    Philips Tempus Pro Patient Monitor Software Update for Operational Issues

    Remote Diagnostic Technologies Ltd. is issuing a software update for the Philips Tempus Pro Patient Monitor due to freezing, rebooting, and potential ECG measurement accuracy issues across multiple software versions.

    Product
    Philips Tempus Pro Patient Monitor, REF: 00-1004-R, 00-1007-R, 00-1024-R, 00-1026-R, 00-1004, 00-1007
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1666-2025·2025-04-30

    Tempus Pro Patient Monitor software error when using video laryngoscope

    Remote Diagnostic Technologies Ltd. is recalling Tempus Pro Patient Monitors due to a software issue that causes an error screen when a video laryngoscope is attached to the device.

    Product
    Tempus Pro Patient Monitor, REFs: 00-1004-R (Tempus Pro non-printer, IBP, without headset dock), 00-1007-R and 00-1007 (Tempus Pro non-printer, IBP, with headset dock), 00-1024-R (Tempus Pro printer), 00-1026-R (Tempus Pro printer, IBP), 00-1007 [(Tempus Pro, BT Dock (IB…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0557-2025·2024-12-04

    Tempus LS-Manual Defibrillator Recalled for Incorrect Servicing Labels

    Remote Diagnostic Technologies Ltd. is recalling Tempus LS-Manual Defibrillator Model 00-3020 units distributed in eight U.S. states. The devices were labeled incorrectly during servicing with wrong product name and CAT number.

    Product
    Tempus LS-Manual Defibrillator Model 00-3020 The Tempus LS-Manual is a defibrillator that can deliver a shock in manual or Pacemaker mode
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2028-2024·2024-06-12

    Philips Tempus LS-Manual Defibrillator may malfunction from electrical interference

    Simultaneous ECG measurements with multiple devices can cause electrical interference that may prevent this defibrillator from functioning properly. The recall affects 1,745 units distributed nationwide.

    Product
    Philips Tempus LS-Manual Defibrillator, Part Number: 00-3020 when using Tempus LS-Manual User/Operator Manual
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2625-2023·2023-09-27

    Philips Tempus Pro Patient Monitor Software Error Impairs Critical Monitoring

    Certain Philips Tempus Pro Patient Monitors may display an error message when laryngoscopes are disconnected, requiring a 60-100 second restart that prevents vital sign monitoring and airway visualization during intubation. This may lead to treatment delays or hypoxia.

    Product
    Philips Tempus Pro Patient Monitor, REF: 00-1004-R, 00-1007-R, 00-1024-R, 00-1026-R, 00-1004, and 00-1007, when Used With Tempus Pro Video Laryngoscope, REF 01-2044
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Devices)·Z-1825-2023·2023-06-21

    Philips Tempus LS-Manual Defibrillator pacing failure due to communication error

    A communication failure in the Philips Tempus LS-Manual Defibrillator may prevent pacing delivery. The device displays an error message and potentially becomes ineffective, affecting approximately 1,147 units distributed nationwide.

    Product
    Philips Tempus LS-Manual Defibrillator, Part Number: 00-3020
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1321-2023·2023-04-12

    Tempus Pro Patient Monitor power supplies recalled for fluid ingress and safety issues

    Remote Diagnostic Technologies is recalling 5,540 Tempus Pro Patient Monitors due to fluid ingress and basic safety issues identified with power supplies during internal testing.

    Product
    Tempus Pro Patient Monitor is a portable vital signs monitor intended to be used by clinicians and medically qualified personnel, for the attended or unattended monitoring of single or multiple vital signs in clinical and pre hospital care applications. The affected power…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0861-2022·2022-04-13

    Defibrillator devices unapproved for US market recalled by FDA

    Remote Diagnostic Technologies recalls Tempus LS defibrillators not approved for US distribution. Two units were distributed in Illinois and Kansas.

    Product
    Tempus LS, Type DGE1, CAT 00-3010, REF 3.940590, Software version 1.3.5, UDI: (01)07613365001693
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1997-2021·2021-07-07

    Tempus Pro Patient Monitor Software Error Risk When Unplugged

    Remote Diagnostic Technologies is recalling Tempus Pro patient monitors (Trizeps 7 variant) that can produce error states when unplugged while connected to a specified laryngoscope device. No injuries have been reported.

    Product
    Tempus Pro - Patient physiological monitor, arrhythmia detector and alarm. Part No. - 00-1004-R, 00-1007-R, 00-1024-R, 00-1026-R. Product Usage: intended to be used as a stand-alone monitor or as a telemedicine system (transmitting patient data to other medical professionals…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0564-2021·2020-12-23

    FDA Recalls Tempus LS Manual Defibrillators Due to Software Error

    Remote Diagnostic Technologies is recalling 175 Tempus LS manual defibrillators because a software error may delay therapy by disrupting ECG calibration.

    Product
    Tempus LS - Manual Defibrillator, Model Number: 00-3020 Software Version: 1.3.4 - Product Usage: The device is intended to be used in the following environmental: - Primarily in pre-hospital care and transport applications (including ambulances, fixed and rotary wing aircraft).
    Category
    Medical Device
    Distribution
    Distributed nationwide