The Recall Desk

Manufacturer

Diagnostica Stago, Inc.

27 recalls in our database name Diagnostica Stago, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
27
Critical
0
Severe
0
Most recent
2026-09-09

Of the 27 recalls from Diagnostica Stago, Inc. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 27

  • ModerateFDA (Devices)·Z-3047-2026·2026-09-09

    Diagnostica Stago Recalls STA Staclot Protein S Reagent Due to QC Drift

    Diagnostica Stago is recalling 5,220 units of STA Staclot Protein S reagent because quality control values drifted within the stated stability period.

    Product
    STA Staclot Protein S, Model/Catalog Number: 00746-Reagent Lot number 273074; qualitative and quantitative factor deficiency test
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1585-2026·2026-03-25

    Stago D-dimer assay shows positive bias across entire analytical range

    Diagnostica Stago is recalling the STA Liatest D-Di kit after investigations confirmed a positive bias in D-dimer measurements throughout the entire analytical range.

    Product
    Brand Name: STA Liatest D-Di Product Name: STA Liatest D-Di Model/Catalog Number: REF 00515 Product Description: in vitro diagnostic. The STA - Liatest D-Di kit is an assay for the quantitative determination of D-dimer in venous plasma for use on STA-R, STA Compact and STA…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1491-2026·2026-03-11

    Stago free protein S assay may underestimate normal range results

    Diagnostica Stago is recalling four lots of the STA Liatest Free Protein S kit because of the potential for out-of-range results and underestimation of free protein S in normal patient plasmas.

    Product
    Brand Name: STA Liatest Free Protein S Product Name: STA Liatest Free Protein S Model/Catalog Number (REF): 00516 Product Description: The STA¿ - Liatest¿ Free Protein S kits are intended for use on STA-R¿ and STA Compact¿ for the quantitative antigenic assay of free protein…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1084-2026·2026-01-21

    Lucky Ice mouthwash recalled over insanitary conditions at a distribution center

    Gold Star Distribution is recalling Lucky Ice Cool Mouthwash over CGMP deviations, citing insanitary conditions including rodent exposure and activity at its distribution center.

    Product
    Asserachrom HPIA. Model/Catalog Number: 00615. The Asserachrom HPIA kit is intended for the qualitative detection in plasma or serum of the anti-heparin-platelet factor 4 (PF4) antibodies generated during the type II heparin-induced thrombocytopenia (HIT type II) by ELISA.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2476-2025·2025-09-03

    Fibrinogen test kits recalled over potential cross-contamination in heparin assays

    STA-Fibrinogen 5 kits are recalled because of the potential for contamination of STA-LIQUID ANTI-Xa by Stago Fibrinogen reagents in heparin applications. 829,800 units are affected, 245,200 of them in the US.

    Product
    STA - Fibrinogen 5. Model/Catalog Number: 00674. The STA - Fibrinogen 5 kit is intended for use with the analyzers of the STA-R, STA Compact and STA Satellite families for the quantitative determination of fibrinogen levels in human citrated plasma by the clotting method…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2474-2025·2025-09-03

    Anti-Xa 4 test kits recalled over potential fibrinogen reagent contamination

    STA-Liquid Anti-Xa 4 kits are recalled because of the potential for contamination by Stago Fibrinogen reagents in unfractionated and low molecular weight heparin applications. 116,600 units are affected.

    Product
    STA-Liquid Anti-Xa 4. Model/Catalog Number: 00311US. The STA - Liquid Anti-Xa kits are intended for use with STA-R, STA Compact and STA Satellite analyzers, for the quantitative determination of the plasma levels of unfractionated (UFH) and low molecular weight (LMWH)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2473-2025·2025-09-03

    Coagulation analyzers recalled over potential reagent contamination in anti-Xa testing

    STA Satellite analyzers are recalled because of the potential for contamination of STA-LIQUID ANTI-Xa by Stago Fibrinogen reagents in unfractionated and low molecular weight heparin applications. 3,650 units are affected.

    Product
    STA Satellite. Product Code: All references. All software versions. The STA Satellite is a fully automated benchtop analyzer capable of simultaneously performing clotting, chromogenic, and immunologic assays.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2475-2025·2025-09-03

    Anti-Xa test kits recalled over potential contamination by fibrinogen reagents

    STA-Liquid Anti-Xa 8 kits are recalled because of the potential for contamination by Stago Fibrinogen reagents in unfractionated and low molecular weight heparin applications. 126,200 units are affected.

    Product
    STA-Liquid Anti-Xa 8. Model/Catalog Number: 00322US. The STA - Liquid Anti-Xa kits are intended for use with STA-R, STA Compact and STA Satellite analyzers, for the quantitative determination of the plasma levels of unfractionated (UFH) and low molecular weight (LMWH)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1993-2025·2025-06-25

    STA-Owren Koller Buffer Solution Recall Due to Clotting Time Concerns

    Diagnostica Stago is recalling STA-Owren Koller buffer solution (Lot 270902) because it may produce shorter clotting times in certain tests, potentially leading to a 1% overestimate of clotting results.

    Product
    STA - Owren Koller. Model/Catalog Number: 00360 STA - Owren-Koller is a buffer solution intended for use as a diluent for reagents and human plasmas in coagulation tests performed with analyzers of the STA-R, STA Compact, STA Satellite and ST art families.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1577-2023·2023-05-17

    STA Compact Max analyzer firmware bug causes inaccurate test results

    A firmware bug in Diagnostica Stago's STA Compact Max analyzer causes intermittent shortened coagulation times and frequent technical errors that produce inaccurate lab test results. Five units were distributed to clinical laboratories nationwide.

    Product
    STA Compact Max fully automatic clinical analyzer, Reference Numbers 58602 and 58612
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1575-2023·2023-05-17

    STA R Max Analyzer Firmware Bug Produces Inaccurate Coagulation Test Results

    Diagnostica Stago is recalling the STA R Max fully automatic clinical analyzer due to a firmware bug that causes intermittent shortened coagulation times and increased technical errors, potentially producing inaccurate blood clotting test results.

    Product
    STA R Max fully automatic clinical instrument designed to perform tests on human plasmas, Reference Numbers 59013 and 59026
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1576-2023·2023-05-17

    STA Compact Analyzer Firmware Bug Causes Inaccurate Test Results

    Diagnostica Stago is recalling STA Compact Analyzers due to a firmware bug causing intermittent shortened coagulation times and increased technical errors. No illnesses or injuries have been reported.

    Product
    STA Compact Automated Multi-Parametric Analyzer, Reference Numbers 58602 and 58612
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1699-2020·2020-04-22

    Stago STA-Deficient VIII Plasma Recalled for Cross-Contamination Risk

    Diagnostica Stago is recalling STA-Deficient VIII plasma due to a risk of sample-to-sample cross-contamination that may cause falsely increased factor VIII levels.

    Product
    STA - Deficient VIII, Product Code: 00725. STA - Deficient VIII is an immuno-depleted human plasma intended for use in tests for the determination of factor VIII activity in plasma on STA-R and STA Compact analyzer platforms as follows: (A) STA-R Max, Product Codes: 58989…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0737-2020·2020-01-01

    Diagnostica Stago Recalls STA Unicalibrator Due to Positive Bias

    Diagnostica Stago is recalling 5,498 units of STA Unicalibrator because a positive bias was confirmed when compared to International Standards.

    Product
    STA UNICALIBRATOR (ref. 00675)
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-0610-2019·2018-12-26

    Diagnostica Stago Recalls Staclot LA Test Kits Due to Result Variability

    Diagnostica Stago is recalling Staclot LA test kits because some results showed shortened times, potentially affecting lupus anticoagulant detection accuracy.

    Product
    Staclot¿ LA (REF 00600) The Staclot¿ LA and Staclot¿ LA 20 test kits are reagent systems designed for the qualitative detection of lupus anticoagulants (LA) in plasma by the use of hexagonal HII phase phospholipid molecules (1, 2).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0611-2019·2018-12-26

    Diagnostica Stago Recalls Staclot LA 20 Test Kits Due to Result Variability

    Diagnostica Stago is recalling Staclot LA 20 test kits because some results showed shortened times outside the expected range.

    Product
    Staclot LA 20 (REF 00594) The Staclot¿ LA and Staclot¿ LA 20 test kits are reagent systems designed for the qualitative detection of lupus anticoagulants (LA) in plasma by the use of hexagonal HII phase phospholipid molecules (1, 2).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2994-2018·2018-09-19

    Diagnostica Stago Recalls STA N¿oplastine¿ CI Reagents Due to Quality Control Issues

    Diagnostica Stago is recalling STA N¿oplastine¿ CI in-vitro diagnostic kits because quality control values fell outside assigned ranges, potentially affecting prothrombin time test results.

    Product
    Diagnostica Stago STA N¿oplastine¿ CI, 10 ml vial. In-Vitro Diagnostic for determination of the prothrombin time (PT) in plasma. REF: 00666 The STA¿ - N¿oplastine¿ CI kits provide reagents for the determination of the prothrombin time (PT) in plasma with STA-R¿, STA…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2993-2018·2018-09-19

    Diagnostica Stago Recalls STA N¿oplastine¿ CI Plus Reagents Due to Quality Control Failures

    Diagnostica Stago is recalling 24,043 kits of STA N¿oplastine¿ CI Plus reagents because quality control values fell outside assigned ranges, potentially affecting prothrombin time test results.

    Product
    Diagnostica Stago STA N¿oplastine¿ CI Plus, 10 ml vial. In-Vitro Diagnostic for determination of the prothrombin time (PT) in plasma. (REF 00667) The STA¿ - N¿oplastine¿ CI Plus kits provide reagents for the determination of the prothrombin time (PT) in plasma with STA-R¿…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1067-2018·2018-03-21

    Diagnostica Stago Recalls Neoplastine Cl Plus Reagent Due to Homogeneity Defect

    Diagnostica Stago is recalling Neoplastine Cl Plus reagent vials because a defect may cause inaccurate prothrombin time test results.

    Product
    Neoplastine¿ Cl Plus ¿ (ref. 00375) Product Usage: Manual or automated determination of the prothrombin time (PT).
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1066-2018·2018-03-21

    Diagnostica Stago Recalls Neoplastine Cl Plus Prothrombin Time Reagent Kits

    Diagnostica Stago is recalling 1,636 Neoplastine Cl Plus kits due to a defect causing inaccurate prothrombin time test results.

    Product
    Neoplastine¿ Cl Plus @ (ref.00374) Product Usage: Manual or automated determination of the prothrombin time (PT).
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1069-2018·2018-03-21

    Diagnostica Stago Recalls STA Neoplastine Cl Plus Reagent Due to Homogeneity Defect

    Diagnostica Stago is recalling STA Neoplastine Cl Plus reagent vials due to a confirmed homogeneity defect that may cause inaccurate prothrombin time test results.

    Product
    STA - Neoplastine¿ Cl Plus ¿ (ref. 00606) Product Usage: Manual or automated determination of the prothrombin time (PT).
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1068-2018·2018-03-21

    Diagnostica Stago Recalls STA Neoplastine Cl Reagent Due to Homogeneity Defect

    Diagnostica Stago, Inc. is recalling STA Neoplastine Cl reagent vials because a homogeneity defect may cause inaccurate prothrombin time test results.

    Product
    STA - Neoplastine¿ Cl ¿ (ref. 00605) Product Usage: Manual or automated determination of the prothrombin time (PT).
    Category
    Medical Device
    Distribution
    0 states
  • LowFDA (Devices)·Z-2650-2014·2014-09-24

    Stago IVD Liquid Anti-Xa Recalled for Barcode Misreading

    Diagnostica Stago is recalling 514 Liquid Anti-Xa kits due to customer complaints about barcode misreading on analyzers.

    Product
    Stago IVD, Liquid Anti-Xa, NDC 3607450003116. The STA - Liquid Anti-Xa kits are intended for use with STA-R, STA Compact and STA Satellite Analyzers for the quantitative determination of the plasma levels of unfractionated (UFH) and low molecular weight (LMWH) heparins by…
    Category
    Medical Device
    Distribution
    Distributed nationwide