The Recall Desk

Manufacturer

Baxter Healthcare Corporation

439 recalls in our database name Baxter Healthcare Corporation as the manufacturing or recalling firm.

What the numbers show

Total
439
Critical
10
Severe
100
Most recent
2026-10-21

Of the 439 recalls from Baxter Healthcare Corporation we have scored against our rubric, 10 (2%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 100 (23%) are Severe.

Which agencies issued them

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

226–250 of 439

  • HighFDA (Devices)·Z-1461-2023·2023-05-03

    GEM NEUROTUBE Nerve Repair Mesh Recalled for Brittleness and Potential Crumbling

    Baxter Healthcare's GEM NEUROTUBE absorbable mesh tube, used for peripheral nerve repair, is recalled because the product is brittle and may crumble when handled or removed from packaging. The recall affects 169 units distributed worldwide.

    Product
    GEM NEUROTUBE, Absorbable Woven Polyglycolic Acid Mesh Tube, Product Codes: a) 5311-01240-010, b) 5311-01240-012; for peripheral nerve repair
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0543-2023·2023-05-03

    Peritoneal dialysis solution recalled due to sterility assurance concerns

    Baxter Healthcare Corporation is recalling 9,788 bags of Dianeal Low Calcium with Dextrose peritoneal dialysis solution due to potential leaks in the Luer component. The recall affects Lot Y405201 distributed nationwide in the United States.

    Product
    DIANEAL LOW CALCIUM WITH DEXTROSE — DIANEAL LOW CALCIUM WITH DEXTROSE (SODIUM CHLORIDE, SODIUM LACTATE, CALCIUM CHLORIDE, MAGNESIUM CHLORIDE AND DEXTROSE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0542-2023·2023-05-03

    Dianeal Low Calcium Dialysis Solution Recalled for Potential Sterility Loss

    Baxter Healthcare is recalling Dianeal Low Calcium peritoneal dialysis solution nationwide due to potential leaks from the container that could compromise sterility. Affected patients should contact their healthcare provider.

    Product
    DIANEAL LOW CALCIUM WITH DEXTROSE — DIANEAL LOW CALCIUM WITH DEXTROSE (SODIUM CHLORIDE, SODIUM LACTATE, CALCIUM CHLORIDE, MAGNESIUM CHLORIDE AND DEXTROSE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1420-2023·2023-04-26

    Baxter ExactaMed Oral Dispenser Recalled for Particulate Matter Contamination

    Baxter Healthcare Corporation is recalling the ExactaMed 20 mL Oral Dispenser (Lot B301S356P) because it may contain particulate matter. The recall affects approximately 91,100 units distributed in the US.

    Product
    ExactaMed Oral Dispenser - 20 mL Clear Pharmacy Pack, REF H9387120; Oral medication syringe
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1316-2023·2023-04-05

    Baxter Automated Peritoneal Dialysis System Electrical Safety Testing Failure

    Baxter Healthcare Corporation is recalling 16 Automated Peritoneal Dialysis Systems due to incomplete electrical safety testing. Affected devices require additional testing.

    Product
    Automated Peritoneal Dialysis System. Used for automatic control of dialysis solution exchanges.
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-1213-2023·2023-03-15

    Baxter peritoneal dialysis cap incorrectly sealed, risks inadequate disinfection

    Baxter MiniCap Disconnect Cap pouches may have faulty seals allowing air exposure, risking inadequate disinfection of the sterile connector used in peritoneal dialysis.

    Product
    Baxter MiniCap Disconnect Cap with Povidone-Iodine Solution, 5C4466P; Accessory to disposable administration set for peritoneal dialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1140-2023·2023-03-08

    Life2000 Hospital Ventilator Recalled for Potential Patient Desaturation Risk

    Baxter Healthcare is recalling 135 Life2000 ventilators nationwide due to potential patient desaturation when connected to an oxygen concentrator.

    Product
    Life2000 Ventilator PKG, Hospital, a) REF BT20007, b) REF BT-20-0007, ventilatory support for the care of individuals
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1141-2023·2023-03-08

    Life2000 Hospital Ventilator Recalled for Patient Desaturation Risk

    Baxter Healthcare is recalling 8 Life2000 Hospital Ventilator systems due to potential patient desaturation events when the device is connected to an oxygen concentrator.

    Product
    Life2000 Ventilator PKG, Hospital, a) REF BT200011, b) REF BT-20-0011, ventilatory support for the care of individuals
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1142-2023·2023-03-08

    Life2000 Ventilator poses oxygen desaturation risk with oxygen concentrators

    The FDA recalls Baxter's Life2000 Ventilator due to potential patient desaturation when connected to an oxygen concentrator. Affects 71 units nationwide.

    Product
    Life2000 Ventilator , REF MS-01-0118, ventilatory support for the care of individuals
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1139-2023·2023-03-08

    Life2000 Ventilator System Recall: Risk of Patient Desaturation

    Baxter Healthcare is recalling 4,279 Life2000 Ventilator Systems due to potential patient desaturation when connected to oxygen concentrators.

    Product
    Life2000 Ventilator System, a) REF BT-20-0002, b) REF BT-20-0002A, ventilatory support for the care of individuals
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1013-2023·2023-02-01

    Baxter ELI 380 Electrocardiograph Recalled After Misdirected Shipment

    Baxter recalls one ELI 380 electrocardiograph that was shipped to a customer in Texas by mistake on 26 October 2022. The device was intended for a pilot program only.

    Product
    Baxter Electrocardiograph, ELI 380 -DCS21
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0760-2023·2022-12-28

    Revaclear 400 Dialyzers Recalled for Potential Internal Blood Leaks

    Baxter Healthcare Corporation is recalling 3.6 million Revaclear 400 Dialyzers due to a manufacturing defect where a twisted gasket could cause internal blood leaks during hemodialysis treatment.

    Product
    Revaclear 400 Dialyzer. Product Code: 114746L. Used to treat chronic and acute renal failure by hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0763-2023·2022-12-28

    Revaclear 400 Dialyzers Recalled for Polyurethane Displacement Risk

    Baxter Healthcare is recalling Revaclear 400 dialyzers due to reports of polyurethane displacement, which could result in blood leaks during dialysis treatment. The recall affects over 6 million units distributed worldwide.

    Product
    Revaclear 400 dialyzers. Indicated for treatment of chronic and acute renal failure by hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0764-2023·2022-12-28

    Baxter Revaclear 400 Dialyzers Recalled for Polyurethane Displacement

    Baxter Healthcare is recalling Revaclear 400 dialyzers because polyurethane displacement may cause blood leaks during dialysis treatment. Approximately 1.14 million units are affected worldwide.

    Product
    Revaclear 400 dialyzers. Indicated for treatment of chronic and acute renal failure by hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0761-2023·2022-12-28

    Revaclear 400 Dialyzer recall due to potential internal blood leaks

    Baxter Healthcare recalls Revaclear 400 Dialyzer units due to potential internal blood leaks caused by twisted gaskets. The defect may affect dialysis patients worldwide.

    Product
    Revaclear 400 Dialyzer. Product Code: 114749M. Not distributed in the USA. Used to treat chronic and acute renal failure by hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0762-2023·2022-12-28

    Baxter Revaclear 300 Dialyzers Recalled for Polyurethane Displacement

    Baxter is recalling approximately 14 million units of Revaclear 300 dialyzers worldwide due to polyurethane displacement that could cause blood leaks. No injuries have been reported.

    Product
    Revaclear 300 dialyzers. Indicated for treatment of chronic and acute renal failure by hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0231-2023·2022-11-23

    Progressa hospital bed compression links may bend during head raising

    Baxter Healthcare is recalling 248 Progressa bed systems. Compression links may bend when raising the head section, even with patients under 500 pounds.

    Product
    Hill-Rom Progressa Bed System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0145-2023·2022-11-09

    Hillrom WatchCare Incontinence System Recalled for Radio Frequency Emissions

    Baxter Healthcare is recalling 129 units of the Hillrom WatchCare incontinence management system due to radio frequency emissions that may interfere with other hospital medical devices such as telemetry units, fetal monitors, and insulin pumps.

    Product
    Hillrom Hospital Bed Accessory, Watch Care Incontinence Management System for VersaCare Bed Rev. A-J, Product Code/Part Number P00697901
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0144-2023·2022-11-09

    Hillrom WatchCare Incontinence System Recalled for Radio Frequency Interference

    Baxter Healthcare recalls the Hillrom WatchCare Incontinence Management System (63 units in US) because radio frequency emissions from the device may interfere with other medical equipment including infusion pumps and insulin pumps.

    Product
    Hillrom Hospital Bed Accessory, WatchCare Incontinence Management System for VersaCare Bed Rev. K, Product Code/Part Number P00697902
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0143-2023·2022-11-09

    Hillrom WatchCare Incontinence System Recalled for Radio Frequency Interference

    Baxter Healthcare recalls the Hillrom WatchCare Incontinence Management System for Progressa Bed due to potential radio frequency emissions that may interfere with other medical devices including telemetry monitors and infusion pumps.

    Product
    Hillrom Hospital Bed Accessory, Watch Care Incontinence Management System for Progressa Bed, Product Code/Part Number P00697903.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0142-2023·2022-11-09

    Hillrom WatchCare Incontinence System recalled for radio frequency interference risk

    Baxter Healthcare is recalling the Hillrom WatchCare Incontinence Management System due to radio frequency emissions that may interfere with other critical medical devices including insulin pumps and fetal monitors.

    Product
    Hillrom Hospital Bed Accessory, Watch Care Incontinence Management System for Centrella Bed, Product Code/Part Number P00697905
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0141-2023·2022-11-09

    Hillrom Centrella Hospital Bed Radio Frequency Emissions May Interfere with Medical Devices

    Hillrom Centrella Hospital Beds with WatchCare systems may emit radio frequency signals that interfere with other medical devices. Approximately 6,407 units are affected and distributed in the US.

    Product
    Hillrom Centrella Hospital Bed with WatchCare Incontinence Management System, Product code/Part numbers: P7900B100193, P7900B100195, P7900B100230, P7900B100236, P7900B100239, P7900B100244, P7900B100256, P7900B100257, P7900B100259, P7900B100264, P7900B100268, P7900B100269…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0179-2023·2022-11-09

    Allen Life Assist Beach Chair Adhesive Cure Failure Recall

    Baxter Healthcare is recalling the Allen Life Assist Beach Chair due to adhesive on fasteners that may not cure correctly, potentially compromising the device's mechanical integrity during surgical procedures.

    Product
    Allen Life Assist Beach Chair, BCSSP-BEACH CHAIR , REF A-91501, #104002. For use with orthopaedic procedures using the Fowlers or beach chair position.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-0178-2023·2022-11-09

    Beach Chair Clamp Shoulder Positioner recalled for adhesive curing failure

    Baxter Healthcare recalls Beach Chair Clamp shoulder positioner components because adhesive on the fasteners may not cure properly, potentially reducing the device's mechanical integrity during surgical procedures.

    Product
    Beach Chair Clamp, BEACH CHAIR SHLDER POSITIONER CMPT, REF A-90013, #800104. Component to position and support the patients head in surgical procedures.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-0177-2023·2022-11-09

    Allen Spine Positioner Components Recalled for Adhesive Curing Defect

    Baxter Healthcare is recalling Allen Standard Starburst spine positioning components due to adhesive that may not cure correctly, potentially compromising mechanical holding force in surgical head positioning devices.

    Product
    Allen Standard Starburst, Mayfield/Doro, STANDARD SPINE POSITIONERS CMPT, REF A-70710, #800103. Component to position and support the patients head in surgical procedures.
    Category
    Medical Device
    Distribution
    4 states

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Baxter Healthcare Corporation

business enterprise in United States of America

Country
United States

Source: Wikidata (Q45134864), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.