The Recall Desk

Hazard

Vessel Damage recalls

10 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
10
Critical
4
Severe
1
Most recent
2022-11-09

Of the 10 vessel damage recalls we have scored against our rubric, 4 (40%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1 (10%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all vessel damage recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–10 of 10

  • HighFDA (Devices)·Z-0170-2023·2022-11-09

    Aneurysm Embolization System Detachment Controller Recalled for Manufacturing Defect

    MICROVENTION is recalling WEB Detachment Controllers due to an out-of-specification tunnel opening that may prevent proper implant detachment. This defect could delay treatment and cause vessel damage from implant manipulation.

    Product
    WEB Detachment Controller, REF: WDC-2, WDC, MV-WDC2. Component of WEB Aneurysm Embolization System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0660-2022·2022-03-02

    Optima Coil System Recalled for Labeling and Packaging Mix-Up

    BALT USA recalls Optima Coil System embolization devices due to labeling/pouch mix-up that could result in incorrect device selection during surgical procedures. Potential harms include vessel damage and aneurysm rupture.

    Product
    The Optima Coil System consists of an implantable embolization coil comprised of a platinum-tungsten alloy attached to a proximal stainless steel hypo-tube and distal body coil delivery pusher with a radiopaque distal positioning marker and proximal fluorosafe marker. The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0848-2021·2021-01-27

    Penumbra JET 7 Reperfusion Catheter Recalled for Potential Tip Damage

    Penumbra Inc. is recalling 3,368 JET 7 Reperfusion Catheters because the distal tip may become damaged during use, posing a risk of vessel damage and patient injury or death.

    Product
    Penumbra JET 7 Reperfusion Catheter REF 5MAXJET7 The Penumbra JET 7 Reperfusion Catheter with Xtra Flex technology (JET 7 Xtra Flex) is a component of the Penumbra system. JET 7 Xtra Flex delivers aspiration from the Aspiration Pump to the site of occlusion to assist in the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0849-2021·2021-01-27

    Penumbra JET 7 Reperfusion Catheter Recalled for Potential Vessel Damage

    Penumbra Inc. is recalling JET 7 Reperfusion Catheters because distal tip damage could cause vessel injury or death during use.

    Product
    Penumbra JET 7 KIT Reperfusion Catheter+Penumbra Hi-Flow Aspiration Tubing REF 5MAXJET7KIT The Penumbra JET 7 Reperfusion Catheter with Xtra Flex technology (JET 7 Xtra Flex) is a component of the Penumbra system. JET 7 Xtra Flex delivers aspiration from the Aspiration Pump…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0850-2021·2021-01-27

    Penumbra JET 7 Reperfusion Catheter Recalled for Potential Tip Damage

    Penumbra Inc. is recalling JET 7 Reperfusion Catheters because distal tip damage could cause vessel injury or death during use.

    Product
    Penumbra JET 7 KIT Reperfusion Catheter+Penumbra Hi-Flow Aspiration Tubing REF 5MAXJET7L138KIT The Penumbra JET 7 Reperfusion Catheter with Xtra Flex technology (JET 7 Xtra Flex) is a component of the Penumbra system. JET 7 Xtra Flex delivers aspiration from the Aspiration…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0851-2021·2021-01-27

    Penumbra JET 7MAX Kits Recalled for Potential Vessel Damage Risk

    Penumbra Inc. is recalling JET 7MAX Kits because catheter tip damage during use could cause vessel damage, leading to patient injury or death.

    Product
    Penumbra JET 7MAX KIT Penumbra JET 7 Reperfusion Catheter+ MAX Delivery Device + Hi-Flow Aspiration Tubing REF J7XKIT132 The Penumbra JET 7 Reperfusion Catheter with Xtra Flex technology (JET 7 Xtra Flex) is a component of the Penumbra system. JET 7 Xtra Flex delivers…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1713-2014·2014-06-11

    Arrow Percutaneous Sheath Introducer Kits Recalled for Dilator Tip Damage

    Arrow International Inc is recalling specific Percutaneous Sheath Introducer Kits due to dilator tip damage that could cause vessel injury.

    Product
    Arrow¿ Percutaneous Sheath Introducer Kits The Percutaneous sheath introducer products permit venous or arterial access and device introduction to the central circulation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1777-2013·2013-07-31

    Ethicon Recalls LIGACLIP Endoscopic Clip Appliers Due to Clip Formation Issues

    Ethicon Endo-Surgery is voluntarily recalling LIGACLIP 10mm M/L Endoscopic Rotating Multiple Clip Appliers due to potential clip formation and feeding issues that may cause vessel damage.

    Product
    LIGACLIP¿ Endoscopic Rotating Multiple Clip Applier (ER320), 10mm M/L, bulk non-sterile Product Usage: The LIGACLIP Endoscopic Rotating Multiple Clip Applier is a single patient use instrument designed to provide a means of ligation through ENDOPATH¿ surgical trocars. The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1775-2013·2013-07-31

    Ethicon Recalls LIGACLIP Endoscopic Clip Appliers Due to Clip Formation Issues

    Ethicon Endo-Surgery is voluntarily recalling LIGACLIP 10mm M/L Endoscopic Rotating Multiple Clip Appliers because potential clip formation and feeding issues may cause vessel damage or insufficient occlusion.

    Product
    LIGACLIP¿ Endoscopic Rotating Multiple Clip Applier (ER320), 10mm M/L Product Usage: The LIGACLIP Endoscopic Rotating Multiple Clip Applier is a sterile, single patient use instrument designed to provide a means of ligation through ENDOPATH¿ surgical trocars. The instrument…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1776-2013·2013-07-31

    Ethicon Recalls LIGACLIP Endoscopic Clip Appliers Due to Clip Formation Issues

    Ethicon Endo-Surgery is voluntarily recalling LIGACLIP 10mm M/L Endoscopic Rotating Multiple Clip Appliers due to potential clip formation and feeding issues that may cause vessel damage.

    Product
    LIGACLIP¿ Endoscopic Rotating Multiple Clip Applier Convenience Kit (Flex Trays), 10mm M/L Product Usage: The LIGACLIP Endoscopic Rotating Multiple Clip Applier is a sterile, single patient use instrument designed to provide a means of ligation through ENDOPATH¿ surgical…
    Category
    Medical Device
    Distribution
    Distributed nationwide