The Recall Desk

Hazard

Under Infusion recalls

60 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
60
Critical
5
Severe
41
Most recent
2025-11-26

Of the 60 under infusion recalls we have scored against our rubric, 5 (8%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 41 (68%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all under infusion recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 60

  • CriticalFDA (Devices)·Z-0430-2026·2025-11-26

    Infusion pump modules recalled because drops can damage the bezel assembly

    CareFusion is recalling 2,574,396 BD Alaris Infusion Pump Modules 8100 because a dropped or jarred pump can suffer bezel damage causing under-infusion, over-infusion or unregulated flow.

    Product
    BD Alaris infusion Pump Module 8100, REF: 8100; KIT, BEZEL ASSY 8100BD, REF: 49000437; KIT ASSY ONE PIECE BEZEL 8100, REF: 49000270. Used with the following new and updated documents: BD Alaris Infusion System Inspection Safety Reminder, Part: BD-163124, Revision: 00…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0744-2024·2024-01-24

    High Pressure Rotator with O-Ring Seal Defect Recalled Worldwide

    Smiths Medical is recalling High Pressure Rotators due to a manufacturing defect affecting O-ring seals. An oversized inner diameter may cause inadequate seal integrity, risking medication under-infusion.

    Product
    HIGH PRESSURE ROTATOR WITH FEMALE LUER LOCK, List Number MX497HP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0746-2024·2024-01-24

    Medex Injection Line Rotating Adapter Recalled Due to O-Ring Defect

    Smiths Medical is recalling Medex injection line rotating adapters due to a manufacturing defect where the O-ring inner diameter may be oversized, potentially causing medication leaks during infusion.

    Product
    Medex 20IN (50.8CM) INJ LINE ROTATING ADAPT, List Number MX682R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0745-2024·2024-01-24

    Braided Injection Line Recalled for Potential Medication Leaks

    Smiths Medical is recalling approximately 31,685 units of a braided injection line due to manufacturing defects in the O-ring seal. The defect may cause medication leaks that reduce drug delivery.

    Product
    20IN (50.8CM) BRAIDED INJ LINE, ROTATING ADAPT, List Number MX682BR
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0742-2024·2024-01-24

    Medex 700PSI Stopcock with Rotator Recalled Due to Seal Defect

    Smiths Medical is recalling Medex 700PSI stopcocks with rotators due to a manufacturing defect affecting the O-ring seal. The defect may cause medication leakage and under-infusion during patient treatment.

    Product
    Medex 700PSI STOPCOCK W/ROTATOR, List Number MX4331R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1434-2022·2022-07-27

    BD Connecta Stopcock recalled for potential housing leakage risk

    Becton Dickinson is recalling BD Connecta Stopcocks due to potential leakage at the housing component. The defect may interrupt treatment and expose patients to biohazardous material.

    Product
    BD Connecta Stopcock Without Extension Tube Catalog No. 394602 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1436-2022·2022-07-27

    BD Connecta 3-Way Stopcocks Recalled Due to Potential Leakage

    Becton Dickinson recalls BD Connecta 3-Way Stopcocks due to potential leakage at the housing that may delay treatment and expose patients to biohazardous material.

    Product
    BD Connecta 3-Way Stopcocks Catalog No. 394900 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1439-2022·2022-07-27

    BD Connecta Plus3 infusion connector recalled for potential stopcock leakage

    Becton Dickinson is recalling BD Connecta Plus3 White Blend infusion connectors (Lot 1127328) due to potential stopcock leakage. The defect may interrupt treatment, expose patients to biohazardous material, or cause under-infusion.

    Product
    BD Connecta" Plus3 White Blend OEM (sterile, bulk) Catalog No. 395214 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0819-2022·2022-03-30

    Infusion Pump Risk of Malfunction in B. Braun Perfusor Space Devices

    B. Braun is recalling 6 Perfusor Space infusion pump units that may not function properly due to inadequate inspection, potentially causing incorrect medication dosing and therapy delays.

    Product
    PERFUSOR SPACE - US VERSION. Intended Use: syringe infusion pump that can be used to configure customized, tailor-made solutions Catalog Number: 8713030U
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-2204-2021·2021-08-18

    Infusion Pump Module Bezel Repair Parts Recalled for Infusion Hazards

    BioMedical Equipment Service Co (BMES) recalls bezel repair parts for Alaris Infusion Pump Module Model 8100. Non-original parts may crack or separate, causing free flow, over-infusion, under-infusion, or interruption of infusion.

    Product
    Alaris Infusion Pump Module, Model 8100, serviced/repaired by Biomedical Equipment Service Co. (BMES) with an impacted bezel repair part TIPA-8100-4410
    Category
    Medical Device
    Distribution
    9 states
  • CriticalFDA (Devices)·Z-1651-2021·2021-06-09

    Alaris Infusion Pump Module Bezel Repair Parts Recalled for Separation Risk

    FDA recalls 22 serviced Alaris Model 8100 infusion pump units with bezel components that may crack or separate, risking free flow, over-infusion, under-infusion, or treatment interruption. Units distributed to Indiana and Texas between September 2020 and February 2021.

    Product
    Alaris Infusion Pump Module, Model 8100, serviced/repaired by The Biomed Guys, with the impacted bezel repair part, TIPA-8100-4410 / Alaris 8100 Bezel.
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-0526-2021·2020-12-09

    CME America Recalls NeoThrive Syringe Pumps Due to Motor Wear

    CME America is recalling 4,182 NeoThrive syringe pumps because motor wear may cause under-infusion without alarms, and cleaning fluids may damage hardware.

    Product
    CME America T-Syringe Pump - NeoThrive - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0527-2021·2020-12-09

    CME America T-Syringe Pump Recall for Motor Wear and Fluid Damage

    CME America is recalling T34L PCA syringe pumps because motor wear may cause under-infusion without alarms, and cleaning fluids may damage hardware.

    Product
    CME America T-Syringe Pump - T34L PCA - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0525-2021·2020-12-09

    CME America T-Syringe Pump Recalled for Motor Wear and Hardware Damage

    CME America is recalling T-Syringe Pumps because motor wear may cause silent under-infusion and cleaning fluids may crack hardware.

    Product
    CME America T-Syringe Pump -T34L - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous, percutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0529-2021·2020-12-09

    CME America T-Syringe Pump Recalled for Motor Wear and Fluid Damage

    CME America is recalling 4,182 T-Syringe Pumps because motor wear may cause under-infusion without alarms, and cleaning fluids may crack hardware.

    Product
    CME America T-Syringe Pump - Ameritus 1st Enteral Pump - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0528-2021·2020-12-09

    CME America Recalls Neofeed Syringe Pumps Due to Motor Wear and Cracks

    CME America is recalling 4,182 Neofeed syringe pumps because motor wear may cause under-infusion without alarms and cracks may allow cleaning fluids to damage hardware.

    Product
    CME America T-Syringe Pump - Neofeed - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous, percutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0530-2021·2020-12-09

    CME America T-Syringe Pump T34 Recalled for Motor Wear and Hardware Cracks

    CME America is recalling 4,182 T-Syringe Pump T34 units because motor wear may cause silent under-infusion and cleaning fluids may crack hardware.

    Product
    CME America T-Syringe Pump - T34 - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous, percutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2736-2020·2020-08-12

    CareFusion Alaris Pump Module Model 8100 Recalled for Broken Platen Elements

    CareFusion 303, Inc. is recalling Alaris Pump Module Model 8100 units because broken platen elements can cause inaccurate fluid delivery, leading to over-infusion, free-flow, or under-infusion.

    Product
    Alaris Pump Module Model 8100
    Category
    Medical Device
    Distribution
    54 states
  • CriticalFDA (Devices)·Z-2553-2020·2020-07-22

    CME BodyGuard BodySet Infusion Sets Recalled for Delivery Inaccuracy

    CME America is recalling BodyGuard BodySet infusion sets because they may deliver therapy at inaccurate rates, potentially causing over-infusion or under-infusion.

    Product
    BodyGuard BodySet, REF: A120-160SAS
    Category
    Medical Device
    Distribution
    49 states
  • CriticalFDA (Devices)·Z-2567-2020·2020-07-22

    CME America Recalls BodyGuard Microset Infusion Sets Due to Delivery Inaccuracy

    CME America, LLC is recalling BodyGuard Microset infusion sets because they may deliver therapy with significant inaccuracy, potentially causing over-infusion or under-infusion.

    Product
    BodyGuard Microset with Needleless Adaptor, REF: A120-003XSNY
    Category
    Medical Device
    Distribution
    49 states
  • SevereFDA (Devices)·Z-2574-2020·2020-07-22

    CME America Recalls BodyGuard Microset Infusion Sets Due to Delivery Inaccuracy

    CME America, LLC is recalling BodyGuard Microset infusion administration sets because they may deliver therapy with an inaccuracy exceeding plus/minus 13%, potentially causing over- or under-infusion.

    Product
    BodyGuard Microset, REF: A100-163XSL
    Category
    Medical Device
    Distribution
    49 states
  • SevereFDA (Devices)·Z-2569-2020·2020-07-22

    CME America Recalls CMExpress Microbore Sets Due to Delivery Inaccuracy

    CME America is recalling CMExpress Microbore Sets because they may deliver therapy at inaccurate rates, potentially causing over-infusion or under-infusion.

    Product
    CMExpress Microbore Set, REF: A120-161CYF
    Category
    Medical Device
    Distribution
    49 states
  • SevereFDA (Devices)·Z-2585-2020·2020-07-22

    CME America Recalls Infusion Sets Due to Delivery Inaccuracy

    CME America is recalling Standard BodySet infusion sets because they may deliver therapy at inaccurate rates, potentially causing over- or under-infusion.

    Product
    Standard BodySet with Needleless Connectors, REF: A120-125XS
    Category
    Medical Device
    Distribution
    49 states