The Recall Desk

Hazard

Test Inaccuracy recalls

55 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
55
Critical
0
Severe
1
Most recent
2026-04-29

Of the 55 test inaccuracy recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1 (2%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all test inaccuracy recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 55

  • HighFDA (Devices)·Z-1336-2022·2022-07-13

    Medical Laboratory Control Material Recalled for Insufficient Glycine Concentration

    Chromsystems is recalling MassCheck Amino Acid Acylcarnitines dried blood spot control material due to too-low glycine concentration in batch 2821. The defect was found in units distributed to New York, Ohio, and Connecticut.

    Product
    MassCheck Amino Acid, Acylcarnitines Dried Blood Spot Control Level I
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-1215-2022·2022-06-08

    BD Anti-Kappa PE Flow Cytometry Reagent May Show Inaccurate Results

    Becton Dickinson is recalling 199 units of BD Anti-Kappa PE flow cytometry reagent because samples may exhibit uncharacteristic flow profiles that could affect test accuracy.

    Product
    BD Anti-Kappa PE (Cat. No. 346587) is an analyte specific reagent for the Anti-Kappa antibody, which specifically recognizes the kappa light chains of human immunoglobulins. Anti-Kappa is used for in vitro identification of cells expressing the kappa light chains using flow cytom
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1096-2022·2022-05-25

    BioPlex 2200 CMV IgM Reagent Pack Recalled for Variable Test Performance

    Bio-Rad Laboratories recalls the BioPlex 2200 ToRC IgM Reagent Pack (Lot 301388) due to CMV IgM analyte showing variable elevated background levels depending on reagent handling.

    Product
    BioPlex 2200 REF 12000670 ToRC IgM Reagent Pack
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0814-2022·2022-03-30

    TCL1 Breakapart Probe May Display Unexpected Genetic Signals

    Cytocell Ltd. is recalling TCL1 Breakapart FISH probes (Lot 074612) because the diagnostic test may show unexpected signals beyond the intended chromosome target.

    Product
    TCL1 Breakapart Probe, Fluorescence in situ hybridisation (FISH) is a technique allows the visualisation of DNA sequences upon chromosome Catalog Number: LPH046-A
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0807-2022·2022-03-23

    BioPlex 2200 Syphilis Calibrator Set Recall Due to Vaccine Interference and Reagent Stability Issues

    Bio-Rad Laboratories is recalling 724 BioPlex 2200 Syphilis Calibrator sets due to COVID-19 vaccine interference concerns and manufacturing problems with reagent stability. The recalled lots were distributed nationwide in the U.S. and internationally.

    Product
    BioPlex 2200 REF 12000651 Syphilis Total & RPR Calibrator Set CAL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0587-2022·2022-02-16

    QC Control Materials KWIK-STIK AST-GP Produce Incorrect Test Results

    Microbiologics Inc recalls KWIK-STIK AST-GP quality control materials that produce incorrect antibiotic susceptibility test results. Two lot numbers were distributed worldwide.

    Product
    QC Sets and Panels, KWIK-STIK AST-GP (4 Strains) QC Set. KWIK-STIK kit that contains Catalog Number 0959P. In Vitro Diagnostic Control microorganisms
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2187-2021·2021-08-11

    Abbott Activated Alanine Aminotransferase Reagent May Produce Inaccurate Patient Results

    Abbott's A-ALT diagnostic reagent may produce inaccurate test results for samples with elevated enzyme or bilirubin levels, potentially affecting patient outcomes. The affected reagent kits have been distributed worldwide.

    Product
    REF 8L92-42, Abbott Activated Alanine Aminotransferase, for use with Architect, IVD, CE, UDI: (01) 00380740161866
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2010-2021·2021-07-14

    Luminex Verigene C. difficile Test Kit Recalled for False-Negative Results

    Luminex Corporation is recalling 1,261 Verigene Clostridium difficile test kits due to potential for false-negative results. The kits may fail to detect C. difficile infections, potentially delaying diagnosis.

    Product
    Verigene Clostridium difficile Nucleic Acid Test Kit (CDF) Model Number: 20-006-022
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1952-2021·2021-07-07

    LeadCare II Blood Lead Test Kit Control Test Inaccuracy Recall

    The LeadCare II Blood Lead Test Kit may generate artificially low control test results, causing blood lead levels to be underestimated in patient samples. Kits were distributed worldwide.

    Product
    LeadCare II Blood Lead Test Kit Catalog Number 70-6762
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1424-2021·2021-04-21

    Remel Haemophilus Test Medium Recalled Due to Growth Issues

    Remel Inc is recalling 408 units of Haemophilus Test Medium because lighter-than-normal growth may make antimicrobial test zones difficult to measure.

    Product
    Remel Haemophilus Test Medium (150 mm) 10/PK, REF 04033 Remel Haemophilus Test Medium (HTM) is a solid medium recommended for use in qualitative procedures by the Clinical and Laboratory Standards Institute (CLSI) as the growth medium for antimicrobial disk diffusion tests wit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1425-2021·2021-04-21

    Remel Haemophilus Test Medium Recalled for Reduced Organism Growth

    Remel Inc is recalling 19 units of Haemophilus Test Medium because lighter-than-normal growth may make antimicrobial test zones difficult to measure.

    Product
    Remel Haemophilus Test Medium(100mm) 10/PK, REF: R01503 Remel Haemophilus Test Medium (HTM) is a solid medium recommended for use in qualitative procedures by the Clinical and Laboratory Standards Institute (CLSI) as the growth medium for antimicrobial disk diffusion tests wi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0881-2021·2021-01-27

    Abbott i-STAT EG7+ Cartridges Recalled for Ionized Calcium Test Inaccuracy

    Abbott Point Of Care Inc. is recalling i-STAT EG7+ cartridges because the ionized calcium test may report higher than expected results if stored at room temperature for specific periods.

    Product
    Abbott i-STAT EG7+ cartridge-IVD. Intended for the quantitative measurement of sodium, potassium, ionized calcium, pH, pCO2, pO2 and hematocrit in venous, arterial or capillary whole blood. List Number: 03P76-25
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1146-2019·2019-04-24

    Roche Lactate Gen.2 Recalled Due to Endogenous Interference Claims

    Roche Diagnostics is recalling Lactate Gen.2 reagents because new endogenous interference claims may affect test accuracy on specific analyzers.

    Product
    Lactate Gen.2, Catalog Nos. 03183700190, 05171881190, 11822837190, ***added as of 5/10/19*** 03183700190 Product Usage: An In vitro diagnostic reagent system intended for use on cobas Integra for the quantitative determination of the lactate concentration in plasma and ce
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1194-2019·2019-04-24

    Roche Albumin BCP Reagent Recalled for Calibration Failures and QC Imprecision

    Roche Diagnostics is recalling 774 units of Albumin BCP reagent due to calibration failures and QC imprecision caused by elevated pH levels.

    Product
    Albumin BCP Product Usage: ALBP is an in vitro test used for the quantitative determination of albumin in human serum and plasma on Roche/Hitachi cobas c systems.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0671-2019·2019-01-02

    Tosoh AIA-PACK B12 Recalled Due to Potential Fluorescein Interference

    Tosoh Bioscience Inc is recalling AIA-PACK B12 reagents because fluorescein interference may cause inaccurately elevated Vitamin B12 test results.

    Product
    AIA-PACK B12 (Vitamin B12) is designed for IN VITRO DIAGNOSTIC USE ONLY for the quantitative measurement of vitamin B12 (B12) in human serum on Tosoh AIA System analyzers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0059-2019·2018-10-10

    Ortho VITROS FSH Reagent Pack Recalled for Potential Biased Results

    Ortho Clinical Diagnostics is recalling VITROS FSH Reagent Packs because biotin supplements may cause biased test results at lower concentrations than indicated.

    Product
    VITROS Immunodiagnostic Products - FSH Reagent Pack (10758750000302) 1931922
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-3179-2018·2018-09-26

    bioMerieux Recalls VITEK 2 AST-P640 Cards Due to Gentamicin Error

    bioMerieux is recalling VITEK 2 AST-P640 cards because some lots contain insufficient gentamicin, potentially affecting high-level resistance test results.

    Product
    VITEK(R) 2 AST-P640, For susceptibility testing of Staphylococcus spp. Enterococcus spp., ad S agalactiae against specified antimicrobials, REF 418579 Product Usage: VITEK¿ 2 is an automated system consisting of instruments, software and reagent cards designed for the identi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2994-2018·2018-09-19

    Diagnostica Stago Recalls STA N¿oplastine¿ CI Reagents Due to Quality Control Issues

    Diagnostica Stago is recalling STA N¿oplastine¿ CI in-vitro diagnostic kits because quality control values fell outside assigned ranges, potentially affecting prothrombin time test results.

    Product
    Diagnostica Stago STA N¿oplastine¿ CI, 10 ml vial. In-Vitro Diagnostic for determination of the prothrombin time (PT) in plasma. REF: 00666 The STA¿ - N¿oplastine¿ CI kits provide reagents for the determination of the prothrombin time (PT) in plasma with STA-R¿, STA Compact¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0911-2018·2018-03-14

    VITROS DAT Performance Verifier I recalled due to labeling issue

    Ortho-Clinical Diagnostics is recalling 349 units of VITROS DAT Performance Verifier I because the storage labeling is incorrect, which may cause lower than expected test results.

    Product
    VITROS Chemistry Products DAT Performance Verifier I in vitro diagnostic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0929-2018·2018-03-14

    Euro Diagnostica Recalls DIASTAT ANA ELISA Kits Due to False Positives

    Euro Diagnostica is recalling 1,090 units of DIASTAT ANA ELISA kits because high background levels may cause false positive test results.

    Product
    DIASTAT anti-Nuclear antibody (ANA) / DIASTAT ANA ELISA. Catalog Number: FANA200. Product Usage: The DIASTAT¿ anti-nuclear antibody (ANA) test is a qualitative enzyme-linked immunosorbent assay (ELISA) for the detection of ANAs in human serum or EDTA plasma. It detects ANAs a
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0086-2018·2017-11-15

    BioMerieux NucliSENS Lysis Buffer Recalled for Potential PCR Inhibition

    BioMerieux SA is recalling 911 units of NucliSENS Lysis Buffer because residual heme may inhibit PCR reactions, leading to uninterpretable test results.

    Product
    NucliSENS Lysis Buffer Extended lot for RES 76675
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1703-2017·2017-04-05

    Siemens Dimension Vista Lab Systems Recalled for Potential ECREA Test Inaccuracy

    Siemens is recalling Dimension Vista 500 and 1500 lab systems because ECREA test results may be falsely elevated in isolated cases.

    Product
    Dimension Vista 500 Intelligent Lab System and Dimension Vista 1500 Intelligent Lab System, analyzer, chemistry (photometric, discrete), for clinical use Product Usage: The Siemens Healthcare Diagnostics Dimension Vista System is an in vitro diagnostic device intended to dupl
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0725-2017·2016-12-14

    Randox Magnesium IVD Reagent Recalled for Carryover Interference

    Randox Laboratories is recalling 15 units of Magnesium IVD reagents for the RX Imola analyser due to carryover interference from amylase tests.

    Product
    Magnesium on RX Imola analyser IVD
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0529-2016·2015-12-30

    Ameditech ProScreen 6 Panel Dip Drug Screen Recall for Reduced Reactivity

    Ameditech is recalling ProScreen 6 Panel Dip Drug Screen kits due to reduced reactivity for two specific benzodiazepine compounds.

    Product
    ProScreen 6 Panel Dip Drug Screen, Item No. PSD-6BUPO3
    Category
    Medical Device
    Distribution
    Distributed nationwide