The Recall Desk

Hazard

Surgical Complication recalls

250 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
250
Critical
3
Severe
41
Most recent
2026-10-07

Of the 250 surgical complication recalls we have scored against our rubric, 3 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 41 (16%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all surgical complication recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

76–100 of 250

  • HighFDA (Devices)·Z-2607-2020·2020-07-22

    Exactech Ossilix Fil Bone Void Filler Recalled for Setting Defects

    Skeletal Kinetics is recalling Exactech Ossilix Fil bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life.

    Product
    EXACTECH OSSILIX FIL (MX), 5CC. Product Number: 660-02-05, UDI: 813845021006 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2627-2020·2020-07-22

    Skeletal Kinetics Recalls Skaflow Flow Bone Void Filler Kits

    Skeletal Kinetics is recalling Skaflow Flow bone void filler kits because they may not maintain setting characteristics for the labeled shelf life.

    Product
    SKAFFOLD FLOW, 3CC and SKAFFOLD FLOW (MX) 3CC. Product Number: SKMX-FL03, UDI: 813845020887 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2623-2020·2020-07-22

    Skeletal Kinetics Recalls Osteovationex Bone Void Filler Kits

    Skeletal Kinetics is recalling Osteovationex bone void filler kits because they may not maintain setting characteristics for the labeled shelf life.

    Product
    OSTEOVATIONEX, INJECT 3CC. Product Number: 390-0003, UDI: 813845020016 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects created…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2617-2020·2020-07-22

    Skeletal Kinetics Recalls Osteovation Bone Void Filler Kits

    Skeletal Kinetics is recalling Osteovation bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life, potentially increasing surgical time or causing bone formation issues.

    Product
    OSTEOVATION, 10CC, INJECT FORMULA. Product Number: 390-2010, UDI: 813845020061 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2633-2020·2020-07-22

    Skeletal Kinetics Recalls Craniosculpt Bone Void Filler Kits

    Skeletal Kinetics is recalling 27 units of Craniosculpt bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life.

    Product
    CRANIOSCULPT, CMF IMPACT, 3CC Product Number: C-CMF3CC, UDI: 813845020931 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects created…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2609-2020·2020-07-22

    Skeletal Kinetics Recalls Ossilix Form Bone Void Filler Kits

    Skeletal Kinetics is recalling 15 units of Ossilix Form bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life.

    Product
    EXACTECH OSSILIX FORM (MX), 5CC. Product Number: 660-01-05, UDI: 813845021020 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2597-2020·2020-07-22

    Skeletal Kinetics Recalls Craniosculpt C Bone Void Filler Kits

    Skeletal Kinetics is recalling Craniosculpt C bone void filler kits because they may not maintain setting characteristics for the labeled shelf life, potentially increasing surgical time or causing bone formation issues.

    Product
    CRANIOSCULPT C, 10CC. Product Number: C-C10CC, UDI: 813845021129 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects created from…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2625-2020·2020-07-22

    Skeletal Kinetics Recalls SKAFFOLD CMF Impress Bone Void Filler Kits

    Skeletal Kinetics is recalling 12 units of SKAFFOLD CMF Impress bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life.

    Product
    SKAFFOLD CMF IMPRESS (MP), 10CC. Product Number: CMMP-IM10, UDI: 813845020696 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2636-2020·2020-07-22

    Skeletal Kinetics Recalls Ossilix Bone Void Filler Kits Due to Setting Defects

    Skeletal Kinetics is recalling 60 units of Ossilix MP Fil bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life.

    Product
    EXACTECH OSSILIX MP FIL, 10CC. Product Number: 662-02-10, UDI: 813845021051 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2619-2020·2020-07-22

    Skeletal Kinetics Recalls Osteovation Bone Void Filler Kits

    Skeletal Kinetics is recalling Osteovation bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life, potentially increasing surgical time or causing bone formation issues.

    Product
    OSTEOVATION, 5CC, IMPACT FORMULA. Product Number: 390-2105, UDI: 813845020085 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2626-2020·2020-07-22

    Skeletal Kinetics Recalls SKAFFOLD CMF Impress Bone Void Filler Kits

    Skeletal Kinetics is recalling SKAFFOLD CMF Impress bone void filler kits because they may not maintain setting characteristics for the labeled shelf life.

    Product
    SKAFFOLD CMF IMPRESS (MP), 5CC. Product Number: CMMP-IM05, UDI: 813845020689 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2629-2020·2020-07-22

    Skeletal Kinetics Recalls SKAFFOLD FLOW Bone Void Filler Kits

    Skeletal Kinetics is recalling SKAFFOLD FLOW bone void filler kits because they may not maintain setting characteristics for the labeled shelf-life, potentially increasing surgical time or causing bone formation issues.

    Product
    SKAFFOLD FLOW, 10CC. Product Number: SKMX-FL10, UDI: 813845020900 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects created from…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2634-2020·2020-07-22

    Skeletal Kinetics Recalls Craniosculpt Bone Void Filler Kits

    Skeletal Kinetics is recalling Craniosculpt bone void filler kits because they may not maintain setting characteristics for the labeled shelf life.

    Product
    CRANIOSCULPT, CMF IMPACT, 5CC, Product Number: C-CMF5CC, UDI: 813845020948 - Product Usage: Callos is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, spine, pelvis). These defects may be surgically created osseous defects or osseous defects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2390-2020·2020-06-24

    Medtronic Bone Void Filler Recalled for Potential Setting Defects

    Medtronic is recalling 36 units of Bone Void Filler, Small, because the product may not maintain its setting characteristics for the labeled shelf-life, potentially increasing surgical time.

    Product
    Medtronic Bone Void Filler, Small - Product Usage: is an injectable, moldable and biocompatible calcium phosphate bone void filler. The single-use Medtronic Bone Void Filler Kit contains the necessary components for mixing of the bone void filler.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2391-2020·2020-06-24

    Medtronic Bone Void Filler Recalled for Potential Setting Defects

    Medtronic is recalling 6 units of Bone Void Filler, Large, because the product may not maintain its setting characteristics for the labeled shelf-life.

    Product
    Medtronic Bone Void Filler, Large - Product Usage: is an injectable, moldable and biocompatible calcium phosphate bone void filler. The single-use Medtronic Bone Void Filler Kit contains the necessary components for mixing of the bone void filler.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2254-2020·2020-06-10

    Multifire Endo Hernia Stapler Recalled for Manufacturing Assembly Error

    Covidien is recalling Multifire Endo Hernia Staplers due to a manufacturing error that may cause staples to fail to advance properly during use.

    Product
    Multifire Endo Hernia 0 12mm Stapler with 4.8mm Disposable Loading Unit , Part No. 174025 - Product Usage: has application in endoscopic general surgery procedures for fixation of mesh in the repair of hernial defects and in other surgical specialties for approximation of…
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2255-2020·2020-06-10

    FDA Recalls Multifire Endo Hernia Staplers Due to Assembly Error

    The FDA is recalling 12,610 Multifire Endo Hernia Staplers due to a manufacturing error that may cause staples to fail to advance properly.

    Product
    Multifire Endo Hernia 0 12mm Stapler with 4.0mm Disposable Loading Unit , Part No. 174027 - Product Usage: has application in endoscopic general surgery procedures for fixation of mesh in the repair of hernial defects and in other surgical specialties for approximation of…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2253-2020·2020-06-10

    FDA Recalls Multifire VersaTrack Auto Suture Hernia Stapler Due to Assembly Error

    The FDA is recalling 12,610 units of the Multifire VersaTrack Auto Suture Hernia Stapler because a manufacturing error may prevent staples from advancing properly.

    Product
    Multifire VersaTrack Auto Suture Hernia Stapler, 4.8mm, Part No. 174023 - Product Usage: has application in endoscopic general surgery procedures for fixation of mesh in the repair of hernial defects and in other surgical specialties for approximation of tissue(s).
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2034-2020·2020-05-27

    Applied Medical Stealth Spring Clip Recall for Insufficient Vessel Occlusion

    Applied Medical Resources Corp is recalling 2,240 units of Stealth Spring Clips due to a failure to provide sufficient occlusion of vessels during surgery.

    Product
    STEALTH SPRING CLIP 6mm latis (1/2 Force). REF/UDI::A1601/(01)00607915110567 - Product Usage: The device is indicated for surgical clamping during cardiovascular, peripheral vascular, and general surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2035-2020·2020-05-27

    Applied Medical Stealth Spring Clip Recall for Insufficient Vessel Occlusion

    Applied Medical Resources Corp is recalling 2,240 units of Stealth Spring Clips due to a risk of insufficient vessel occlusion during surgery.

    Product
    STEALTH SPRING CLIP 6mm latis (1/4 Force). REF/UDI::A1602/(01)00607915110574 - Product Usage: The device is indicated for surgical clamping during cardiovascular, peripheral vascular, and general surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2026-2020·2020-05-27

    K2M Aleutian Lordotic Spreader Recalled for Welded Tip Breakage Risk

    K2M, Inc. is recalling the Aleutian Anatomically Narrow Lordotic Spreader because the welded tip may break off during surgical procedures.

    Product
    K2M, ALEUTIAN Interbody Spacer Systems, EN AN Lordotic Spreader, Stainless Steel, Non-Sterile, Qty 1, Catalog # 5203-90165, UDI # 10888857108783, Size 28x6mm, 12 Product Usage: Used to simulate the height of the cage and expand the spine disc space to determine the optimal…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1458-2020·2020-03-18

    Nextremity Solutions Recalls Nextra Hammertoe Correction System Due to Driver Defect

    Nextremity Solutions is recalling 190 units of the Nextra Hammertoe Correction System because the driver may be oversized, making it difficult to remove from the implant.

    Product
    Nextra Hammertoe Correction System-4.5MM Middle, 3.2MM Proximal, SS, Sterile. REF: NX-4532K - Product Usage: The Nextra Hammertoe Correction System is a system of implants and associated instruments which is indicated for small bone reconstruction limited to inter-digital…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1473-2020·2020-03-18

    Medicrea Iliac Screws Recalled Due to Incorrect Component Orientation

    Medicrea International is recalling 3,529 Iliac Screws because an internal component was assembled incorrectly, which may cause the tulip head to disengage from the shank.

    Product
    Iliac Screws, multiple sizes, Article Nos. B36020500 B36020570 B36020580 B36020590 B36027500 B36027570 B36027580 B36027590 B36028500 B36028570 B36028580 B36028590 B36029500 B36029570 B36029580 B36029590 Screws manufactured in titanium alloy Ti-6Al-4V LI…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1147-2020·2020-02-19

    Stryker Omega PEEK Knotless Anchor System Recalled for Driver Removal Issues

    Stryker is recalling 73 Omega PEEK Knotless Anchor Systems because high driver removal forces can cause the screw to pull out of the bone.

    Product
    Stryker, Omega 4.75 mm,. PEEK Knotless Anchor System, Double-Double, REF 3910-500-472, UDI 07613327464832, Sterile R, RX Only CE 0197
    Category
    Medical Device
    Distribution
    19 states
  • SevereFDA (Devices)·Z-0780-2020·2020-01-15

    Stryker T2 Alpha Delta Strike Plate Recalled for Breakage Risk

    Stryker GmbH is recalling T2 Alpha Delta Strike Plate instruments because they can break during nail implantation or removal, potentially causing complications.

    Product
    Stryker T2 Alpha Delta Strike Plate IMN Instruments - part of the IMN Instruments System and is used to support insertion and withdrawal of nails through the Targeting Device Catalog Number: 2351-0050
    Category
    Medical Device
    Distribution