28 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
28
Critical
0
Severe
8
Most recent
2025-09-24

Of the 28 loss of therapy recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 8 (29%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all loss of therapy recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 28

  • HighFDA (Devices)·Z-2558-2025·2025-09-24

    Deep brain stimulation implant manuals recalled after wire breaks in generators

    The Vercise Deep Brain Stimulation Systems Surgical Implant Manual is being recalled after wire breaks in rechargeable pulse generators implanted in the submuscular pectoral location. 25,260 units are affected.

    Product
    Vercise Deep Brain Stimulation Systems Surgical Implant Manual, Document Number: 92328632-09
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1073-2025·2025-02-12

    VNS Therapy Generator May Stop Delivering Stimulation Due to Mechanical Defect

    LivaNova's SenTiva VNS generators (48 units) may stop delivering stimulation due to a mechanical defect. Patients may experience return to baseline seizure or depressive symptoms and may require replacement surgery.

    Product
    SenTiva, REF: 1000C, Generators Part of the VNS Therapy System with Microburst Stimulation. Used for Vagus Nerve Stimulation (VNS).
    Category
    Medical Device
    Distribution
    41 states
  • HighFDA (Devices)·Z-2429-2024·2024-07-31

    Abbott Infinity 5 Pulse Generator May Have Inaccurate Battery-Life Labels

    Abbott Infinity 5 implantable pulse generators have inaccurate end-of-service dates in labeling, which may result in loss of therapy. Approximately 5,900 units are affected and distributed worldwide.

    Product
    Abbott Infinity 5, Implantable Pulse Generator, REF: 6660, SterileEO, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2432-2024·2024-07-31

    Abbott Infinity 7 Implantable Pulse Generators Recalled for Potentially Shortened Service Life

    Abbott is recalling 1198 Infinity 7 Implantable Pulse Generators due to potentially incorrect service life indicators and end-of-service dates in product labeling, which could result in loss of therapy.

    Product
    Abbott Infinity 7, Implantable Pulse Generator, REF: 6663, SterileEO, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2430-2024·2024-07-31

    Abbott Infinity 5 Pulse Generator May Fail Prematurely

    Abbott is recalling 5,900 Infinity 5 implantable pulse generators because the replacement indicator and end-of-service date may be shorter than labeled, potentially causing premature device failure. Patients should contact their doctor about device status.

    Product
    Abbott Infinity 5, Implantable Pulse Generator, REF: 6661, SterileEO, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2431-2024·2024-07-31

    Abbott Infinity 7 Pulse Generator May Have Shorter-Than-Labeled Service Date

    The Abbott Infinity 7 implantable pulse generator's replacement indicator and end-of-service date may be shorter than the product labeling states, potentially leading to loss of therapy for patients.

    Product
    Abbott Infinity 7, Implantable Pulse Generator, REF: 6662, SterileEO, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2257-2024·2024-07-10

    Nalu Neurostimulation Kits Recalled for Manufacturing Defect and Device Failure

    Nalu Medical recalls 13 neurostimulation and peripheral nerve stimulation kits due to a manufacturing defect that may prevent the implantable pulse generator from functioning, stopping pain signal inhibition.

    Product
    Neurostimulation Kit (Ported, Dual 8, 40 cm), REF: 71005-US Peripheral Nerve Stimulation Kit (Ported, Dual 8, 40 cm), REF: 71019-US Components of the Nalu Spinal Cord Stimulation System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1813-2024·2024-05-29

    BiPAP A40 ventilators risk therapy loss during alarm condition

    BiPAP A40 ventilators may lose therapy delivery during a Ventilator Inoperative alarm, potentially causing respiratory failure or death in vulnerable patients.

    Product
    BiPAP A40 Ventilators: BiPAP A40, Part Numbers 1111169 (US and OUS) and (OUS ONLY)1111170 1111171 1111173 1111174 1111175 1111177 1116156 1111170S BR1111169 CN1111169 IT1111169 R1111169 R1111177 R1116156 ; BiPAP A40 Pro, Part Numbers (OUS Only)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0532-2022·2022-02-09

    Vagus Nerve Stimulation Therapy Leads Recalled for Tubing Wall Defect

    LivaNova's PerenniaDURA vagus nerve stimulation leads may have insufficient silicone tubing thickness due to a manufacturing issue. This could result in unintended stimulation delivery or loss of therapy if the tubing is breached.

    Product
    Vagus Nerve Stimulation (VNS) Therapy Leads, PerenniaDURA, Model: 303. Model 303-20 PereniaDURA Lead (2.0 mm electrode inner diameter) and Model 303-30 PereniaDURA Lead (3.0 mm electrode inner diameter)
    Category
    Medical Device
    Distribution
    7 states
  • SevereFDA (Devices)·Z-1306-2021·2021-04-07

    Medtronic Recalls CRT-D Devices Due to Shortened Replacement Time

    Medtronic is recalling specific CRT-D implantable cardioverter defibrillators because a small percentage may experience a shortened time before the device reaches end of service.

    Product
    Implantable cardioverter defibrillators (ICD) with cardiac resynchronization therapy (CRT-D): 1) Viva family: Viva XT CRT-D, Viva XT Quad CRT-D, Viva S CRT-D, Viva Quad S CRT-D and Viva Quad C CRT-D models; 2) Claria family: Claria MRI CRT-D and Claria MRI Quad CRT-D models; 3)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2825-2018·2018-08-22

    Sorin Platinium CRT-D Recall Due to Loss of Pacing and Sensing

    Sorin CRM SAS is recalling 10 Platinium CRT-D devices because a hardware issue may cause loss of pacing and sensing, preventing the device from detecting arrhythmias.

    Product
    Sorin Platinium CRT-D 1741 DF-4, Sterile EO. Implantable Cardiac Defibrillator and Resynchronization Therapy Defibrillator
    Category
    Medical Device
    Distribution
    9 states
  • SevereFDA (Devices)·Z-2417-2018·2018-07-18

    Medtronic EnTrust ICD Recall for Potential Loss of High Voltage Therapy

    Medtronic is recalling 8,890 EnTrust ICDs due to a potential loss of high voltage therapy near end-of-life. Patients should contact their healthcare provider.

    Product
    Medtronic EnTrust Dual Chamber Implantable Cardioverter Defibrillator with Atrial and Ventricular Therapies and RapidRead Telemetry, D154ATG Product Usage: The device indicated for use in ICD patients with atrial tachyarrhythmias, or who are at significant risk of developing…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2418-2018·2018-07-18

    Medtronic EnTrust ICD Recall for Potential Loss of High Voltage Therapy

    Medtronic is recalling 3 EnTrust ICDs because they may lose high voltage therapy near battery end-of-life without prior warning.

    Product
    Medtronic EnTrust SingleChamber Implantable Cardioverter Defibrillator with Atrial and Ventricular Therapies and RapidRead Telemetry, D153VRC Product Usage: The implantable cardioverter defibrillator is intended to provide ventricular antitachycardia pacing and ventricular…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2420-2018·2018-07-18

    Medtronic EnTrust Escudo ICD Recall for Potential Loss of Therapy

    Medtronic is recalling EnTrust Escudo ICDs due to a potential loss of high voltage and anti-tachycardia pacing therapy as the battery nears its end of life.

    Product
    Medtronic EnTrust Escudo D144VRC (OUS distribution) Product Usage: The implantable cardioverter defibrillator is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2419-2018·2018-07-18

    Medtronic EnTrust ICD Recall for Potential Loss of High Voltage Therapy

    Medtronic is recalling 8,821 EnTrust ICDs due to a potential loss of high voltage therapy near end-of-life. Patients should contact their healthcare provider.

    Product
    Medtronic EnTrust SingleChamber Implantable Cardioverter Defibrillator with Atrial and Ventricular Therapies and RapidRead Telemetry, D154VRC Product Usage: The implantable cardioverter defibrillator is intended to provide ventricular antitachycardia pacing and ventricular…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2421-2018·2018-07-18

    Medtronic EnTrust Escudo ICD Recall for Potential Loss of Therapy

    Medtronic is recalling 1,867 EnTrust Escudo ICDs because they may lose high-voltage therapy without a prior alert.

    Product
    Medtronic EnTrust Escudo D144DRG (OUS distribution) Product Usage: The implantable cardioverter defibrillator is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2416-2018·2018-07-18

    Medtronic EnTrust ICD Recall for Potential Loss of High Voltage Therapy

    Medtronic is recalling 103 EnTrust Dual Chamber ICDs because they may lose high voltage and anti-tachycardia pacing therapy near end-of-life without prior warning.

    Product
    Medtronic EnTrust Dual Chamber Implantable Cardioverter Defibrillator with Atrial and Ventricular Therapies and RapidRead Telemetry, D153ATG Product Usage: The device indicated for use in ICD patients with atrial tachyarrhythmias, or who are at significant risk of developing…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3020-2017·2017-08-23

    Cyberonics Recalls VNS Therapy Generators Due to Reduced Longevity

    Cyberonics is recalling 1,909 VNS Therapy AspireHC and AspireSR generators because a manufacturing defect may cause them to lose battery life faster than expected.

    Product
    VNS Therapy¿ AspireHC¿ Generator, VNS Therapy¿ AspireSR¿ Generator. Model No. 106. Product Usage: United States Indications for Use: Epilepsy (PMA 970003): The VNS Therapy System is indicated for use as an adjunctive therapy in reducing the frequency of seizures in adults…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2695-2017·2017-07-19

    St. Jude Medical Recalls Infinity 7 Implantable Pulse Generators

    St. Jude Medical is recalling 373 Infinity 7 Implantable Pulse Generators because exposure to monopolar electrosurgical devices may cause a loss of neuromodulation therapy.

    Product
    Infinity 7, Implantable Pulse Generator, REF 6662, Rx only, STERILE EO Product Usage: The Infinity IPG is an electronic device designed to be connected to one or two extensions. It is powered by a hermetically sealed battery within a titanium case and uses microelectronic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2694-2017·2017-07-19

    St. Jude Medical Recalls Infinity 5 Implantable Pulse Generators

    St. Jude Medical is recalling 54 Infinity 5 Implantable Pulse Generators due to a risk of therapy loss if exposed to monopolar electrosurgical devices.

    Product
    Infinity 5, Implantable Pulse Generator, REF 6661, Rx only, STERILE EO Product Usage: The Infinity IPG is an electronic device designed to be connected to one or two extensions. It is powered by a hermetically sealed battery within a titanium case and uses microelectronic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2696-2017·2017-07-19

    St. Jude Medical Recalls Infinity 7 Implantable Pulse Generators

    St. Jude Medical is recalling 40 Infinity 7 Implantable Pulse Generators because exposure to monopolar electrosurgical devices during medical procedures may cause a loss of neuromodulation therapy.

    Product
    Infinity 7, Implantable Pulse Generator, REF 6663, Rx only, STERILE EO Product Usage: The Infinity IPG is an electronic device designed to be connected to one or two extensions. It is powered by a hermetically sealed battery within a titanium case and uses microelectronic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2691-2017·2017-07-19

    St. Jude Medical Recalls Proclaim 5 Elite Implantable Pulse Generators

    St. Jude Medical is recalling 8,780 Proclaim 5 Elite implantable pulse generators due to a risk of losing neuromodulation therapy when exposed to monopolar electrosurgical devices.

    Product
    Proclaim 5 Elite, implantable Pulse Generator, REF 3660, Rx only, STERILE EO Product Usage: The Proclaim implantable pulse generator (IPG) is an electronic device designed to be connected to one or more extensions or leads with up to 16 electrodes total. It is powered by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2693-2017·2017-07-19

    St. Jude Medical Recalls Infinity 5 Implantable Pulse Generators

    St. Jude Medical is recalling 443 Infinity 5 Implantable Pulse Generators due to a risk of losing neuromodulation therapy when exposed to monopolar electrosurgical devices.

    Product
    Infinity 5, Implantable Pulse Generator, REF 6660, Rx only, STERILE EO, Product Usage: The Infinity IPG is an electronic device designed to be connected to one or two extensions. It is powered by a hermetically sealed battery within a titanium case and uses microelectronic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2692-2017·2017-07-19

    St. Jude Medical Recalls Proclaim 7 Elite Implantable Pulse Generators

    St. Jude Medical is recalling 9,529 Proclaim 7 Elite implantable pulse generators due to a risk of losing neuromodulation therapy when exposed to monopolar electrosurgical devices.

    Product
    Proclaim 7 Elite, Implantable Pulse Generator, REF 3662, Rx only, STERILE EO Product Usage: The Proclaim implantable pulse generator (IPG) is an electronic device designed to be connected to one or more extensions or leads with up to 16 electrodes total. It is powered by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1926-2016·2016-06-15

    Medtronic RestoreSensor Implantable Neurostimulators Recalled for Battery Depletion

    Medtronic is recalling RestoreSensor implantable neurostimulators because insufficient coupling during recharging can cause rapid battery depletion and loss of therapy.

    Product
    Medtronic RestoreSensor, Model 37714; and, RestoreSensor SureScan, (MRI), Model 97714, Implantable Neurostimulators. Used to treat chronic, intractable pain of the trunk and/or limbs-including unilateral or bilateral pain.
    Category
    Medical Device
    Distribution
    0 states