The Recall Desk

Hazard

Delayed Diagnosis recalls

57 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
57
Critical
0
Severe
2
Most recent
2026-08-12

Of the 57 delayed diagnosis recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2 (4%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all delayed diagnosis recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 57

  • SevereFDA (Devices)·Z-2900-2026·2026-08-12

    GEM Premier 5000 PAK Lysing Solution Concentration Recall

    Specific lots of the GEM Premier 5000 PAK lysing bag solution have an active ingredient concentration that does not meet manufacturing specifications, which could delay recognition and management of Co-Oximetry and total bilirubin abnormalities.

    Product
    GEM Premier 5000 PAK Part Numbers: 00055360010 00055360011 00055407504 00055415010 00055430010 00055430011 00055445010 00055445011 00055360010.A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1957-2025·2025-06-18

    KWIK-STICK Quality Control Kit for Culture Media Swab Mix-Up

    Microbiologics Inc is recalling KWIK-STICK quality control kits because products were packaged with incorrect microorganism swabs, which may lead to delayed diagnosis of patient samples in clinical laboratories.

    Product
    KWIK-STICK, Quality control kit for culture media, Catalog Numbers 01065K, Oligella urethralis derived from ATCC¿ 17960; 0621K, Staphylococcus aureus derived from NCTC 12493
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0317-2025·2024-11-13

    Shimadzu FLUOROspeed X-ray System Software Recall for Image Display Failure

    Shimadzu is recalling 30 FLUOROspeed X-ray systems because software may fail to display images when switching modes, potentially delaying or canceling examinations.

    Product
    The FLUOROspeed is intended to be used as a universal diagnostic imaging system for radiographic and fluoroscopic studies. Using a flat detector, it can perform a range of applications including general R/F, angiography and pediatric examinations. FLUOROspeed may be used for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0258-2025·2024-11-06

    17-OH Progesterone ELISA Kit Recalled for Labeling Discrepancy

    DRG International is recalling 504 units of its 17-OH Progesterone ELISA kit (Model EIA-1292) due to mismatched control acceptance ranges between the Certificate of Analysis and component labels, causing test failure.

    Product
    17-OH Progesterone ELISA 96 well kit- An enzyme immunoassay for the quantitative in vitro diagnostic measurement of 17-OH Progesterone (17-OHP) in serum or plasma Model/Catalog Number: EIA-1292
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-3303-2024·2024-10-09

    Urinalysis reagent strips recalled for reduced protein detection sensitivity

    Healgen Scientific is recalling 1,636,994 urinalysis test strips in California, Georgia, and Texas due to reduced protein detection sensitivity that may produce false negative results and delay kidney disease diagnosis.

    Product
    Healgen Series Reagent strips for Urinalysis are composed of several color pads aligned on a test strip. Each pad is employed for testing one assay item by visually or instrumentally reading the color change of the pad and comparing with the corresponding blocks on a color…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3202-2024·2024-10-02

    Philips MR 7700 MRI Scanner Recall for Loose Screws

    Philips is recalling 7 MR 7700 MRI scanners because loose screws may block the tabletop, potentially delaying diagnosis or causing patient anxiety.

    Product
    MR 7700 -For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782120
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1476-2024·2024-04-10

    Abbott ARCHITECT STAT Myoglobin Reagent Kit recalled due to manufacturing defect

    Abbott is recalling certain myoglobin test kits because of manufacturing defects that could lead to incorrect results and delayed heart attack diagnosis.

    Product
    ARCHITECT STAT Myoglobin Reagent Kit, LN 2K43-25 and 2K43-20.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1039-2024·2024-02-14

    BD BBL Sensi Disc Antibiotic Test Discs Recalled for Accuracy Failures

    Becton Dickinson is recalling BD BBL Sensi Disc antibiotic susceptibility test discs due to potential accuracy and quality control failures that may lead to incorrect antibiotic selection and delayed diagnosis.

    Product
    BD BBL Sensi Disc Sulfamethoxazole with Trimethoprim 23.75/1.25 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231536 and 231539¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1031-2024·2024-02-14

    BD BBL Sensi Disc Imipenem susceptibility test accuracy and quality failures

    BD BBL Sensi Disc Imipenem susceptibility test discs may fail to accurately assess antibiotic resistance. This could delay diagnosis or lead to inappropriate antibiotic treatment selection.

    Product
    BD BBL Sensi Disc Imipenem- 10 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231644 and 231645¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1017-2024·2024-02-14

    Medical Device Recall: BD BBL Cefaclor Antibiotic Susceptibility Test Disc

    Becton Dickinson is recalling BD BBL Sensi Disc Cefaclor antibiotic susceptibility test discs due to possible accuracy and quality control failures. Affected discs may produce inaccurate results, risking delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Cefaclor - 30 ug¿, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231653¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1035-2024·2024-02-14

    BD BBL Moxifloxacin Test Discs Recalled for Susceptibility Testing Inaccuracy

    BD BBL Sensi Disc Moxifloxacin test discs are recalled due to possible failures in antibiotic susceptibility testing accuracy. Test failures could lead to delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Moxifloxacin- 5 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231758¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0608-2024·2023-12-27

    RAPIDPoint 500 Measurement Cartridge Sodium Sensor May Cause Measurement Error

    Siemens RAPIDPoint 500 cartridges may produce inaccurate sodium measurements in blood samples, potentially delaying diagnosis or causing inappropriate treatment. The sodium sensor may show a negative bias, affecting patient care.

    Product
    RAPIDPoint 500 Systems Measurement Cartridge (with Lactate) 400-Intended for in vitro diagnostic use and is designed to provide the determination in whole blood. SMN: 10491448
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0609-2024·2023-12-27

    RAPIDPoint 500 Measurement Cartridge Sodium Sensor Negative Bias Risk

    Siemens RAPIDPoint 500 measurement cartridges may produce inaccurate sodium readings, risking delayed diagnosis of dangerous electrolyte imbalances or unnecessary treatment.

    Product
    RAPIDPoint 500 Systems Measurement Cartridge (with Lactate) 750-Intended for in vitro diagnostic use and is designed to provide the determination in whole blood. SMN: 10491449
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0606-2024·2023-12-27

    RAPIDPoint 500 Measurement Cartridges Recalled for Sodium Sensor Bias

    Siemens is recalling RAPIDPoint 500 Systems Measurement Cartridges because the sodium sensor can develop a negative measurement bias that could delay diagnosis of serious electrolyte disorders or cause treatment errors.

    Product
    RAPIDPoint 500 Systems Measurement Cartridge (with Lactate) 100 -Intended for in vitro diagnostic use and is designed to provide the determination in whole blood. SMN: 10844813
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0607-2024·2023-12-27

    RAPIDPoint 500 Diagnostic Cartridges Recall Due to Sodium Sensor Measurement Bias

    Siemens is recalling RAPIDPoint 500 measurement cartridges because the sodium sensor can produce inaccurate readings, potentially leading to delayed diagnosis or incorrect treatment of electrolyte imbalances.

    Product
    RAPIDPoint 500 Systems Measurement Cartridge (with Lactate) 250-Intended for in vitro diagnostic use and is designed to provide the determination in whole blood. SMN: 10491447
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0236-2024·2023-11-15

    Laboratory Lipase Test Slides Recalled for Measurement Bias Risk

    Ortho-Clinical Diagnostics is recalling VITROS Lipase Slides due to measurement abnormalities that could result in falsely low or elevated test results. This could delay diagnosis of acute pancreatitis or cause diagnostic confusion.

    Product
    VITROS Chemistry Products Lipase Slides, Product Codes 1668409 (contains 60 Slides per Cartridge) and 8297749 (contains 18 slides per cartridge)
    Category
    Medical Device
    Distribution
    12 states
  • HighFDA (Devices)·Z-2623-2023·2023-09-27

    VITROS XT Chemistry TBIL-ALKP Slides recalled for incorrect liver enzyme readings

    Ortho-Clinical Diagnostics is recalling VITROS XT Chemistry TBIL-ALKP Slides because they may report incorrectly low liver enzyme values, potentially leading to missed or delayed liver disease diagnoses. Approximately 52,456 units were distributed worldwide.

    Product
    VITROS XT Chemistry Products TBIL-ALKP Slides
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2245-2023·2023-08-02

    Respiratory Diagnostic Test Kits Recalled for Decreased Performance Reliability

    Qiagen's QIAstat-Dx Respiratory SARS-CoV-2 Panel diagnostic kits are recalled due to decreased performance reliability. Failed test runs could require sample retesting, potentially delaying diagnosis.

    Product
    QIAstat-Dx Respiratory SARS-CoV-2 Panel -US IVD qualitative test intended for analyzing nasopharyngeal swab (NPS) samples from patients suspected of respiratory infection for the presence of viral or bacterial nucleic acids REF 691223
    Category
    Medical Device
    Distribution
    14 states
  • ModerateFDA (Devices)·Z-2246-2023·2023-08-02

    COVID-19 Diagnostic Test Kits Recalled Due to Performance Reliability Issues

    Qiagen has recalled 4155 QIAstat-Dx Respiratory SARS-CoV-2 Panel kits due to decreased performance reliability. Test failures (run abortions) may require samples to be retested, potentially delaying diagnosis.

    Product
    QIAstat-Dx Respiratory SARS-CoV-2 Panel (V1 and V2, CE IVD, not US IVD, not sold in the US.) Qualitative test intended for analyzing nasopharyngeal swab (NPS) samples from patients suspected of respiratory infection REF: 691214
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-1682-2023·2023-06-14

    BD Veritor System Instructions for Use Not FDA Approved

    The Instructions for Use for BD Veritor System rapid diagnostic tests for COVID-19 and flu were not FDA-approved, lacking proper specimen type specifications. Using the test with invalid specimen types could produce false positive or negative results, potentially delaying diagnosis or treatment.

    Product
    BD Veritor System for Rapid Detection of SARS-CoV-2 & Flu A+B, 30 Single Use Test Devices- Intended for the in vitro, simultaneous qualitative detection and differentiation of SARS-CoV-2 nucleocapsid antigen and influenza A and/or B Catalog Number: 256088
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1106-2023·2023-02-15

    Roche Influenza A/B and RSV Test Kit Recalled for False Negative Results

    Roche Molecular Systems recalled 727 diagnostic test kits used to detect influenza and RSV due to reports of false negative influenza A results that could delay proper diagnosis and treatment.

    Product
    cobas Influenza A/B & RSV UC (Utility Channel) Qualitative nucleic acid test for use on the cobas 6800/8800 Systems; Material number 09233962190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1105-2023·2023-02-15

    Roche cobas Influenza Test Recall Due to False Negative Results

    Roche Molecular Systems is recalling its cobas Influenza A/B & SARS-CoV-2 test because it has reported false negative results for Influenza A, which may delay diagnosis and treatment.

    Product
    cobas SARS-CoV-2 & Influenza A/B Qualitative nucleic acid test for use on the cobas 5800/6800/8800 Systems; Material Number 09446125190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1104-2023·2023-02-15

    Roche cobas Flu/COVID assay recalled for false negative influenza results

    Roche Molecular Systems recalls cobas SARS-CoV-2 & Influenza A/B assay kits used in clinical laboratories. The kits may produce false negative Influenza A results, potentially delaying accurate diagnosis.

    Product
    cobas SARS-CoV-2 & Influenza A/B Qualitative assay for use on the cobas 6800/8800 Systems; Material number 09233474190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0355-2023·2022-12-14

    Siemens IMMULITE Testosterone Assay Recalled for Measurement Bias

    Siemens is recalling two lots of its IMMULITE Total Testosterone Assay due to a confirmed 40% positive measurement bias at higher testosterone levels, which may delay diagnosis and require repeat testing.

    Product
    IMMULITE and IMMULITE 1000 Total Testosterone Assay- In vitro diagnostic use with the IMMULITE and IMMULITE 1000 Analyzers for the quantitative measurement of total testosterone in serum and heparinized plasma.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0425-2022·2022-01-05

    VIDAS diagnostic test for C. difficile recalled due to substrate defect

    bioMerieux's VIDAS Clostridium difficile diagnostic test is being recalled due to a substrate error that prevents the test from running. Users must re-test samples, potentially delaying diagnosis.

    Product
    VIDAS Clostridium Difficile Toxin A&B, CDAB,REF 30118-01
    Category
    Medical Device
    Distribution
    Distributed nationwide