The Recall Desk

Hazard

Adhesive Defect recalls

26 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
26
Critical
0
Severe
4
Most recent
2026-04-29

Of the 26 adhesive defect recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 4 (15%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all adhesive defect recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 26

  • HighFDA (Devices)·Z-1913-2026·2026-04-29

    Arrow Epidural Catheter Kits Recalled Due to Adhesive Manufacturing Defect

    Arrow International is recalling FlexTip Plus Epidural Catheter and FlexBlock Continuous Peripheral Nerve Block Catheter Kits due to incorrect manufacturing of liquid adhesive. The recall affects 190 units distributed nationwide.

    Product
    FLEXTIP PLUS EPIDURAL CATHETER;FLEXBLOCK CONTINOUS PERIPHERAL NERVE BLOCK CATHETER KIT/SET REF ASK-05502-BSM UDI code: (01)10801902209853(17)270831(11)251210(10)33F25K0409 The Arrow Epidural Catheter kit permits access to the epidural space for administration of epidural…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0695-2025·2024-12-25

    HUDSON RCI mBrace ET Tube Holder Risks Facial Dermal Injury

    Medline is recalling the HUDSON RCI mBrace ET tube holder because defective adhesive and frame elements may cause pressure and skin injury to the face.

    Product
    HUDSON RCI mBrace, ET Tube Holder and 2 Point Head Strap, REF DYNJMBRC2; tracheal tube fixation device
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Drugs)·D-0055-2025·2024-11-27

    Prescription Dextroamphetamine Patches Recalled for Defective Adhesive System

    Noven Pharmaceuticals Inc is recalling 685 boxes of XELSTRYM (dextroamphetamine) transdermal patches nationwide due to a defect in the adhesive delivery system. The product does not meet manufacturing specifications.

    Product
    XELSTRYM — XELSTRYM (DEXTROAMPHETAMINE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1781-2024·2024-05-15

    GE Allia IGS Fluoroscopic X-Ray Systems Adhesive Bolt Defect

    GE Healthcare recalled certain Allia IGS and related fluoroscopic x-ray systems due to potential incomplete adhesive on bolts in the gantry assembly, risking detector or tube failure.

    Product
    GE Healthcare Allia IGS 7 OR, Interventional fluoroscopic x-ray systems
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1306-2024·2024-03-27

    Natus Sleep Supplies Recalled for Conductive Adhesive Gel Quality Defects

    Natus Neurology is recalling Sleep Supplies Start Kits due to defective conductive adhesive gel supplied by Parker Laboratories. The gel is too thick, discolored, and caused patient irritation in at least one case.

    Product
    natus neurology, Sleep Supplies Start Kit with Single Use Supplies for Embla EX Series Amplifiers, REF 024252
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1212-2024·2024-03-06

    Olympus colonoscope PCF-H190TL recalled for missing protective adhesive

    Olympus has recalled certain repaired colonoscope models lacking protective adhesive that could fail under vibration, temperature, or severe shock loads. Affected models include the PCF-H190TL, distributed nationwide.

    Product
    Colonoscope, Model Number PCF-H190TL.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0071-2023·2022-12-07

    Daytrana transdermal methylphenidate patches recalled for adhesive defect

    Noven Pharmaceuticals recalls 3,977 boxes of Daytrana methylphenidate transdermal patches nationwide due to defective adhesive properties in lot 91316. Affected patches may fail to adhere properly or deliver medication inconsistently.

    Product
    DAYTRANA — DAYTRANA (METHYLPHENIDATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0325-2023·2022-12-07

    3M Steri-Drape Surgical Drapes Recalled Due to Adhesive Liner Defect

    3M is recalling Steri-Drape Surgical Drapes because the liner on the adhesive component is difficult to remove without damaging the product, potentially rendering it unusable.

    Product
    Busse JOINT INJECTION TRAY -Intended as a nerve block REF No. 8561 R1
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0263-2023·2022-11-30

    3M Steri-Drape Surgical Drape Recall for Adhesive Defect and Skin Injuries

    3M is recalling 554,200 surgical drapes due to a difficult-to-remove adhesive liner that may damage the product and render it unusable. The company has received reports of adhesive-related skin injuries from the affected lots.

    Product
    3M Steri-Drape, Medium Drape with Incise Film and Pouch, REF 1061NS, general surgery drape
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0261-2023·2022-11-30

    3M Steri-Drape surgical drapes recalled due to adhesive skin injuries

    3M is recalling 103,000 units of Steri-Drape surgical drapes worldwide due to difficulties removing the adhesive liner and an increase in reported skin injuries from the adhesive.

    Product
    3M Steri-Drape, Medium Drape with Incise Film, REF 1060NS, general surgery drape
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0251-2023·2022-11-30

    3M Steri-Drape Surgical Drapes Recalled Due to Adhesive Defects and Skin Injuries

    3M is recalling Steri-Drape Large Towel Drapes (REF 1010NS) due to adhesive liner defects that may damage the product and increased reports of adhesive-related skin injuries from affected lots.

    Product
    3M Steri-Drape, Large Towel Drape, REF 1010NS, general surgery drape
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0247-2023·2022-11-30

    3M Steri-Drape surgical drape with defective adhesive liner recalled

    3M is recalling Steri-Drape Small Towel Drapes because the adhesive liner is difficult to remove without damaging the product and has caused reported skin injuries.

    Product
    3M Steri-Drape, Small Towel Drape, REF 1000, general surgery drape
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0176-2023·2022-11-09

    Baxter Neurosurgical Headrest Recalled Due to Defective Adhesive

    Baxter Healthcare is recalling C-Flex Polar Head Positioning Device neurosurgical headrests because adhesive on fasteners may not cure correctly, potentially compromising mechanical integrity and holding force.

    Product
    C-Flex Polar Head Positnr-Device Only, SSP-NEUROSURGICAL HEADREST, REF A-70701, #103001,
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1263-2022·2022-06-22

    Olympus Uretero-Reno Fiberscope Recalled for Defective Adhesive and Vision Loss

    The Olympus URETERO-RENO FIBERSCOPE Model URF-P6 is recalled for incorrect adhesive securing the diopter ring. The defect may cause loss of adjustment function, blurred vision, and in rare cases, urinary tract perforation.

    Product
    Olympus URETERO-RENO FIBERSCOPE Model: URF-P6
    Category
    Medical Device
    Distribution
    9 states
  • HighFDA (Devices)·Z-1016-2022·2022-05-04

    Empower Introducer Sheath Recalled for Defective Glue and Embolism Risk

    Freudenberg Medical is recalling the Empower Introducer Sheath due to defective adhesive on the catheter shaft that could cause blood clots and tissue damage.

    Product
    Empower Introducer Sheath with Hydrophilic Coating 21F x 56cm Model: 668782-100 (US)
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Drugs)·D-1209-2018·2018-10-03

    Noven Recalls Minivelle Estradiol Patches Due to Adhesive Defect

    Noven Pharmaceuticals is recalling Minivelle (estradiol) transdermal patches because the adhesive delivery system failed to meet specification standards for shear.

    Product
    MINIVELLE — MINIVELLE (ESTRADIOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1207-2018·2018-10-03

    Noven Recalls Minivelle Estradiol Patches Due to Adhesive Defect

    Noven Pharmaceuticals is recalling Minivelle (estradiol) transdermal patches because the adhesive delivery system failed to meet specification standards for shear.

    Product
    MINIVELLE — MINIVELLE (ESTRADIOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1210-2018·2018-10-03

    Noven Recalls Minivelle Estradiol Patches Due to Adhesive Defects

    Noven Pharmaceuticals is recalling Minivelle (estradiol) transdermal patches because the adhesive delivery system failed to meet specification standards for shear.

    Product
    MINIVELLE — MINIVELLE (ESTRADIOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1208-2018·2018-10-03

    Noven Recalls Minivelle Estradiol Patches Due to Adhesive Defect

    Noven Pharmaceuticals is recalling Minivelle (estradiol) transdermal patches because the adhesive delivery system failed to meet specification standards for shear.

    Product
    MINIVELLE — MINIVELLE (ESTRADIOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1174-2018·2018-04-04

    ConMed Mini Infant Radiotranslucent Electrodes Recalled for Adhesive Defect

    ConMed is recalling 18,720 Mini Infant Radiotranslucent Electrodes because adhesive on contact wires may impede conductivity and cause device failure.

    Product
    MINI INFANT < 3KG, RADIOTRANSLUCENT ELECTRODE, Universal/Anderson Connector, REF/Catalog Number 2602 Indicated for use in external pacing, defibrillation and monitoring applications as a non-sterile, disposable device for single pediatric use, only. The PadPro 2602 electrodes…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2084-2015·2015-07-22

    NDI Disposable Reflective Marker Spheres Recalled for Adhesive Defect

    Northern Digital Inc. is recalling NDI Disposable Reflective Marker Spheres because inadequate adhesive curing may cause the spheres to separate.

    Product
    NDI Disposable Reflective Marker Spheres for Brainlab IGS (Image Guided Surgical) system. Product Usage: Disposable reflective marker spheres are attached to reference arrays and instruments, thus enabling the infrared tracking systems to detect the position of the patient…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0435-2014·2013-12-11

    CareFusion Recalls VersaSafe Extension Sets Due to Adhesive Defect

    CareFusion is recalling VersaSafe Extension Sets because excessive adhesive may prevent the male spin collar from operating as intended.

    Product
    VersaSafe Extension Set, Model No. 21000M-007
    Category
    Medical Device
    Distribution
    Distributed nationwide