The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

8676–8700 of 40095

  • HighFDA (Devices)·Z-0421-2024·2023-12-06

    Medtronic Insertable Cardiac Monitor May Fail to Record Heart Rhythms

    Medtronic recalled 64,739 ICM LNQ22 LINQ II insertable cardiac monitors due to potential amplified noise or signal reduction that may interfere with heart rhythm recordings.

    Product
    ICM LNQ22 LINQ II, Model LNQ22; Insertable Cardiac Monitor
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0414-2024·2023-12-06

    Edwards TruWave pressure monitoring kit recalled for setup issues

    Edwards Lifesciences is recalling 168,014 TruWave with Vamp pressure monitoring kits due to potential flushing difficulties during setup. The recall affects devices distributed across the US and internationally.

    Product
    TruWave with Vamp System Pressure monitoring set, REF: PXAVMP(3cc)/VAMP 68 in (173cm) PXAVMP3: x3 (3cc)/VAMP PXVK0364:(3cc)/VAMP 96in (241cm); PXVK0853: x3 (3cc)/VAMP 76in (193cm); PXVK0996:(3cc)/VAMP 68in (174cm); PXVMP2X21: x2 (3cc)/VAMP; PXVMP2X22: x2 (3cc)/VAMP 63 in
    Category
    Medical Device
    Distribution
    51 states
  • HighFDA (Devices)·Z-0406-2024·2023-12-06

    Da Vinci Needle Driver Recalled for Risk of Dislodgement During Surgery

    Intuitive Surgical is recalling 317 units of a Da Vinci Single-Site Wristed Needle Driver due to potential dislodgement or breakage that could result in uncontrollable movement.

    Product
    Da Vinci Single-Site Wristed Needle Driver, REF: 478115, 5 mm
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0419-2024·2023-12-06

    Olympus EVIS EXERA III Colonoscope Recall for Connector Defect

    24 Olympus EVIS EXERA III colonoscopes distributed to six states are recalled due to improperly repaired connectors that may cause image loss, decreased suction, or improper reprocessing, potentially exposing patients to contaminated equipment.

    Product
    PCF-H190L, EVIS EXERA III COLONOVIDEOSCOPE
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-0416-2024·2023-12-06

    Improperly Repaired Gastrointestinal Videoscope May Expose Patients to Contamination

    Aizu Olympus gastrointestinal videoscopes (GIF-H190) may have defective repairs that prevent proper sterilization, risking patient exposure to contaminated material. Affected units were distributed to medical facilities in six states.

    Product
    GIF-H190, EVIS EXERA III GASTROINTESTINAL VIDEOSCOPE
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-0411-2024·2023-12-06

    FloTrac Sensor Recalled Due to Potential Flushing Difficulties During Setup

    Edwards Lifesciences is recalling 1417 FloTrac Sensors used for intravascular pressure monitoring due to potential flushing difficulties during kit setup. No illnesses or injuries have been reported.

    Product
    FloTrac Sensor, REF: MHD8 & MHD85,MHD6R5, MHD8R, MHD8R5, MHD8S, STERILEEO, Rx only. For use in intravascular pressure monitoring.
    Category
    Medical Device
    Distribution
    51 states
  • HighFDA (Devices)·Z-0423-2024·2023-12-06

    RAPIDPOINT 500 Blood Gas System: Drug Interference May Cause False Sodium Readings

    Siemens RAPIDPOINT 500 Blood Gas System may produce falsely elevated sodium results due to drug interference from Perhexiline Maleate or Atomoxetine Hydrochloride. This could lead to missed hyponatremia or inappropriate treatment of hypernatremia.

    Product
    RAPIDPOINT 500 Blood Gas System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0417-2024·2023-12-06

    Gastrointestinal Videoscope Recall Due to Improper Repair and Infection Risk

    Aizu Olympus recalls 24 gastrointestinal videoscopes with improperly repaired light guide connectors. The defect may cause loss of image and suction, preventing proper device reprocessing and risking patient infection.

    Product
    GIF-HQ190, EVIS EXERA III GASTROINTESTINAL VIDEOSCOPE
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-0403-2024·2023-12-06

    Medical device for hearing exams recalled for technical distortion issues

    PATH is recalling AuDX PRO hearing examination devices because they may produce technical distortions greater than expected, which could affect diagnostic accuracy. The recall affects 23 units distributed in Florida, Missouri, Ohio, and Wisconsin.

    Product
    AuDX PRO, mobile medical devices for hearing examinations, Model Number SOH100098, Part Number 100098-AUP
    Category
    Medical Device
    Distribution
    4 states
  • ModerateFDA (Devices)·Z-0413-2024·2023-12-06

    TruWave Pressure Monitoring Set Recalled for Potential Flushing Difficulties

    Edwards Lifesciences is recalling 118,570 units of the TruWave Pressure Monitoring Set due to potential flushing difficulties during setup. The device is used for hemodynamic pressure monitoring.

    Product
    TruWave Pressure monitoring set, REF: PX212: cc/12 in (30cm), PX260: (3 cc/60in (150cm), PX272: 3 cc/72in (180cm), PX284: 3 cc/84 in (210 cm), PX2X2: x2 (3cc), PX3X3284C: X3 (3cc), PX4X4: x4 (3cc), PX600F (3cc), PXMK1876: x 3 (3 cc), PXMK1940: (3 cc), PXMK2024: (3cc)/77 in (196cm
    Category
    Medical Device
    Distribution
    51 states
  • ModerateFDA (Devices)·Z-0412-2024·2023-12-06

    FloTrac Pressure Monitoring Sensor Recalled for Setup Flushing Difficulties

    Edwards Lifesciences' FloTrac Sensor with Vamp System is being recalled due to potential flushing difficulties during setup of the pressure monitoring kit. No injuries have been reported.

    Product
    FloTrac Sensor with Vamp System, REF: MHD6AZ, MHD6AZ5 , MHD6C502 STIRLEEO, Rx only. For use in intravascular pressure monitoring.
    Category
    Medical Device
    Distribution
    51 states
  • ModerateFDA (Devices)·Z-0410-2024·2023-12-06

    Intravascular Pressure Sensor Recalled for Flushing Difficulties During Setup

    Edwards Lifesciences is recalling Acumen IQ intravascular pressure monitoring sensors (6,714 units) due to potential flushing difficulties during setup of the pressure monitoring kit.

    Product
    Acumen IQ Sensor with VAMP System, REFs: AIQS6AZ & AIQS6AZ5, STERILEEO, Rx only. For use in intravascular pressure monitoring.
    Category
    Medical Device
    Distribution
    51 states
  • ModerateFDA (Devices)·Z-0408-2024·2023-12-06

    Iodine Solution Recalled for Improper Bottle Cap Seal

    EMD Millipore's Lugol's Iodine Solution (Lot 3124) is recalled due to an improper seal between the cap and bottle, which allows iodine vapors to dissipate and reduces the product's potency over time.

    Product
    Lugol s Iodine Solution 500ML, Part Number 624-71
    Category
    Medical Device
    Distribution
    3 states
  • CriticalFDA (Devices)·Z-0234-2024·2023-11-29

    VariSoft Insulin Infusion Set Recalled Over Premature Connector Disconnection

    Unomedical recalls 3,362 units of VariSoft infusion sets due to connector damage causing premature disconnection and missed insulin doses, risking dangerous elevation of blood glucose and ketone levels.

    Product
    VariSoft infusion set, Model Number 1002830
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0233-2024·2023-11-29

    VariSoft Infusion Set Model 1002828 Recalled for Connector Detachment Risk

    The FDA recalls 1,679 VariSoft infusion sets (Model 1002828) due to connector damage that causes improper detachment. Undetected disconnections can lead to missed insulin doses and diabetic ketoacidosis.

    Product
    VariSoft infusion set, Model Number 1002828
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0232-2024·2023-11-29

    VariSoft Infusion Set recalled for defective connector prone to unintended disconnection

    Unomedical is recalling 8,028 VariSoft infusion sets due to a manufacturing defect that makes the connector prone to unintended disconnection, potentially leading to missed insulin doses and serious blood glucose complications.

    Product
    VariSoft infusion set, Model Number 1002827
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0377-2024·2023-11-29

    Biomet Anchor Plugs Recalled: Metal Burrs Prevent Proper Assembly

    Biomet's Compress Device Segmental Anchor Plugs are being recalled due to metal burrs in assembly holes. The defect prevents drill pins from passing through, potentially extending surgical time during implantation procedures.

    Product
    Compress Device Segmental Anchor Plug, 24 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178414
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0384-2024·2023-11-29

    Compress Device Short Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (22 MM) used in orthopedic surgery because they may contain metal burrs in the transverse holes that could prevent drill or pin passage and extend surgical procedures.

    Product
    Compress Device Short Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178564
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0349-2024·2023-11-29

    BD Alaris Pump Infusion Sets Contain Undisclosed DEHP

    BD Alaris Pump infusion sets labeled as DEHP-free actually contain di(2-ethylhexyl) phthalate. The worldwide recall affects multiple catalog numbers distributed throughout the US and internationally.

    Product
    BD Alaris Pump infusion sets (Product Name, Catalog #) BD AlarisTM Pump Infusion Set Vented syringe adapter Smallbore Tubing, Catalog # 10010483; BD AlarisTM Pump Infusion Set 1.2 Micron Filter Low Sorbing Tubing (PE Lined) SmartSiteTM Y-site, Catalog # 10010453; BD Alar
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0376-2024·2023-11-29

    Compress Device Anchor Plugs Recalled for Metal Burrs in Surgical Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs that may prevent surgical instruments from passing through properly. The defect may result in extended surgery time.

    Product
    Compress Device Segmental Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178412
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0375-2024·2023-11-29

    Biomet Compress Device Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs in transverse holes that may prevent proper device function during surgery. The defect could result in extended surgical time.

    Product
    Compress Device Segmental Anchor Plug, 20 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178410
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0332-2024·2023-11-29

    Rhinolaryngoscope Models Recalled for Unvalidated Air Drying Process

    Aizu Olympus rhinolaryngoscopes (models ENF-T3, ENF-VT2, ENF-VT3) are recalled. The air-drying process for the instrument channel was not validated, and water remaining in some devices after repair poses contamination and infection risk.

    Product
    Rhinolaryngoscope-for endoscopic diagnosis and treatment within the nasal lumens and airway anatomy (including nasopharyngeal and trachea). Model Numbers: ENF-T3, ENF-VT2, ENF-VT3.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0378-2024·2023-11-29

    Biomet Compress Device Anchor Plugs recalled for metal burrs in transverse holes

    Biomet is recalling Compress Device Short Anchor Plugs due to potential metal burrs in the transverse holes that may prevent proper placement of drill pins during surgery, potentially extending surgical time.

    Product
    Compress Device Short Anchor Plug, 10 MM-Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178552
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0374-2024·2023-11-29

    Biomet Compress Anchor Plugs Recalled for Metal Burrs in Transverse Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs (18 MM) due to metal burrs in transverse holes that may prevent proper drill or pin placement, potentially extending surgery time.

    Product
    Compress Device Segmental Anchor Plug, 18 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178408
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0344-2024·2023-11-29

    Transnasal Esophagovideoscope Recalled Due to Unvalidated Drying Process

    Aizu Olympus is recalling the Transnasal Esophagovideoscope (Model PEF-V) because the channel air drying process was not validated, resulting in some units with wet channels that could cause infection.

    Product
    Transnasal esophagovideoscope-For endoscopy and endoscopic surgery within the esophagus and stomach. Model Number: PEF-V.
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.