Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

8026–8050 of 40007

  • HighFDA (Devices)·Z-1020-2024·2024-02-14

    Cefotaxime antibiotic susceptibility test discs recalled for potential testing accuracy failures

    BD BBL Sensi Disc Cefotaxime susceptibility testing discs may produce inaccurate results for H. influenzae, potentially leading to delayed diagnosis and inappropriate antibiotic selection. The FDA has recalled 2,363,168 units distributed domestically and internationally.

    Product
    BD BBL Sensi Disc Cefotaxime - 30 ug¿, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231606 and 231607¿; 5 ug, Catalog No. 291308¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1000-2024·2024-02-14

    Hip Arthroplasty Surgical Instruments Recalled for Sterile Barrier Failure

    Howmedica Osteonics Corp. is recalling hip arthroplasty surgical instruments after their sterile packaging failed integrity testing. Units with compromised packaging were distributed worldwide.

    Product
    HRIS ACET CUP CUT TIP 32X140 Part Number: 6210-5-200rker. single-use, sterile surgical instruments used during hip arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0988-2024·2024-02-14

    Anesthesia System Cybersecurity Vulnerability Poses Denial of Service Risk

    The Flow-i C30 Anesthesia System contains a cybersecurity vulnerability allowing remote attackers to cause denial of service, tampering, or code execution, potentially creating hazardous conditions.

    Product
    Flow-i C30 Anesthesia System, model 6677300
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0996-2024·2024-02-14

    Globus Medical Cranial Drill recalled for potential sterility compromise

    Globus Medical is recalling Cranial Drills due to potential sterility loss from packaging breaches and discoloration at the drill tip. The drills are used in cranial surgery with the ExcelsiusGPS system.

    Product
    Globus Medical Cranial Drill with Stop, 3.20mm - instruments for access, preparation, and placement of cranial devices with the ExcelsiusGPS. Ref: 6143.1842S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0973-2024·2024-02-14

    Ingenia 1.5T Patient Trolley Wheels May Attract to MRI Magnetic Field

    Philips is recalling Ingenia 1.5T patient transportation trolleys with magnetic wheels that could be attracted to MRI magnetic fields. These wheels pose a potential hazard in MRI-equipped facilities when the trolley operates near the magnetic field.

    Product
    Ingenia 1.5T (Product Number 781396) - HA FlexTrak II (Accessory Number 989710008732), patient transportation system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1012-2024·2024-02-14

    BD antibiotic susceptibility testing discs recalled for accuracy failures

    Becton Dickinson is recalling BD BBL Sensi Disc Ampicillin antibiotic susceptibility testing discs due to accuracy and quality control failures that may cause delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Ampicillin - 10 ¿g, Catalog No. 230705 and 231264; 2 ¿g, Catalog No. 231263. Used for semi-quantitative in vitro susceptibility testing.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1005-2024·2024-02-14

    Medical Device Recall: Guardian 4 Glucose Sensor Manufacturing Defect

    Medtronic is recalling Guardian 4 Glucose Sensors due to manufacturing defects in the glucose oxidase layer. Defects may cause sensors to malfunction or provide inaccurate readings, potentially affecting insulin dosing.

    Product
    Guardian 4 Glucose Sensor, REF: MMT-7040A, MMT-7040C1, MMT-7040C2, MMT-7040C3, MMT-7040D1, MMT-7040D2, MMT-7040MA, MMT-7040QC1, MMT-7040QC2, MMT-7040QC3
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1042-2024·2024-02-14

    Prestige Coil System Recalled for Risk of Foreign Emboli from Corroded Delivery Pusher

    BALT USA is recalling Prestige Coil Systems due to corrosion of the delivery pusher. Solder flux residue can cause the discolored hypotube to break off and enter patient blood vessels as foreign emboli.

    Product
    The Prestige Coil System is a product family of embolic coils with associated delivery system components. These devices are angiographically delivered through the vasculature to embolize peripheral vascular abnormalities. The devices are to be placed to create blood stasis, reduc
    Category
    Medical Device
    Distribution
    28 states
  • HighFDA (Devices)·Z-1016-2024·2024-02-14

    BD antibiotic susceptibility test discs recalled for possible accuracy failures

    BD BBL Sensi Disc Aztreonam test discs are recalled due to possible accuracy and quality control failures in antibiotic susceptibility testing. Failures could result in delayed diagnoses and inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Aztreonam - 30 ug¿, used for semi-quantitative in vitro susceptibility testing. Catalog Numbers 231640¿and 231641.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1025-2024·2024-02-14

    Antibiotic susceptibility testing discs recalled for potential accuracy failures

    Becton Dickinson's BD BBL Sensi Disc Cefuroxime testing discs may have accuracy, reproducibility, or quality-control failures in antibiotic susceptibility testing. This could delay diagnosis and lead to inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Cefuroxime- 30 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231621¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1034-2024·2024-02-14

    Antibiotic Susceptibility Test Discs Recalled for Accuracy and QC Failures

    Becton Dickinson is recalling BD BBL Sensi Disc Minocycline test discs due to potential accuracy and quality control failures that may cause delayed test results, missed diagnoses, or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Minocycline - 30 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231250 and 231251¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0991-2024·2024-02-14

    Flow-e Anesthesia System Model 6887900 Cybersecurity Vulnerability Recall

    The Flow-e Anesthesia System model 6887900 is recalled due to a cybersecurity vulnerability that could allow remote access, denial of service, or code execution, potentially affecting anesthesia delivery safety.

    Product
    Flow-e Anesthesia System, model 6887900
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1014-2024·2024-02-14

    BD Antibiotic Testing Discs Recalled for Accuracy Failures

    Becton Dickinson recalled BD BBL Sensi Disc Augmentin testing discs due to potential accuracy and quality control failures in antibiotic susceptibility testing. Failures may lead to delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Augmentin - 3¿g, Catalog Number 291270¿used for semi-quantitative in vitro susceptibility testing.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0997-2024·2024-02-14

    Globus Medical Cranial Drill recalled for sterility breach risk

    Globus Medical is recalling Cranial Drill 6.00mm units due to potential packaging breaches that may render the sterile product non-sterile, and discoloration near the drill tip.

    Product
    Globus Medical Cranial Drill, 6.00mm - instruments for access, preparation, and placement of cranial devices with the ExcelsiusGPS. Ref: 6143.1870S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0987-2024·2024-02-14

    Flow-i C20 Anesthesia System cybersecurity vulnerability could enable remote attacks

    The Flow-i C20 Anesthesia System has a cybersecurity vulnerability allowing potential remote access, denial of service attacks, or code execution. Healthcare facilities should contact the manufacturer for patches and guidance.

    Product
    Flow-i C20 Anesthesia System, model 6677200
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1022-2024·2024-02-14

    BD BBL Sensi Disc Ceftaroline test discs recalled for accuracy failures

    Becton Dickinson is recalling BD BBL Sensi Disc Ceftaroline test discs due to potential accuracy and quality control failures in antibiotic susceptibility testing. Incorrect test results may delay diagnosis and lead to inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Ceftaroline - 30 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 232231¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1007-2024·2024-02-14

    Globus Medical Cannula May Not Be Properly Sterilized

    Some ExcelsiusGPS Cannulas have an internal gap that prevents proper sterilization, increasing infection risk. Globus Medical is recalling 570 units distributed worldwide.

    Product
    ExcelsiusGPS Cannula A, 9mm x 250mm, Cannula used with ball tip probes, Model No. 6143.2844
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1030-2024·2024-02-14

    BD BBL Ertapenem Susceptibility Test Discs Recalled for Accuracy Failures

    BD BBL Sensi Disc Ertapenem test discs are being recalled due to reproducibility and accuracy failures that may cause diagnostic errors, delayed diagnosis, or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Ertapenem- 10 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 232174 and 232175¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1032-2024·2024-02-14

    BD BBL Sensi Disc Levofloxacin Testing Discs Recalled for Accuracy Failures

    Becton Dickinson is recalling 2,363,168 units of BD BBL Sensi Disc Levofloxacin testing discs (Catalog No. 231705, 231706) due to potential accuracy and quality control failures in antibiotic susceptibility testing that could lead to delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Levofloxacin- 5 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231705 and 231706¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1033-2024·2024-02-14

    BD BBL Sensi Disc Meropenem testing discs recalled for accuracy failures

    Becton Dickinson is recalling BD BBL Sensi Disc Meropenem antibiotic susceptibility testing discs due to accuracy and quality control failures that may cause delayed or incorrect diagnostic results.

    Product
    BD BBL Sensi Disc Meropenem- 10 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231703 and 231704¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1026-2024·2024-02-14

    Antibiotic Susceptibility Testing Disc Recall Due to Accuracy Concerns

    BD BBL Sensi Disc Chloramphenicol test discs may have accuracy and quality control failures during antibiotic susceptibility testing. This could cause delayed results or inappropriate antibiotic selections.

    Product
    BD BBL Sensi Disc Chloramphenicol- 30 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 230733¿and 231274¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0989-2024·2024-02-14

    Flow-i C40 Anesthesia System Recalled for Cybersecurity Vulnerability

    Getinge's Flow-i C40 Anesthesia System (model 6677400) contains a potential cybersecurity vulnerability allowing remote login attacks that could result in denial of service, system tampering, or remote code execution.

    Product
    Flow-i C40 Anesthesia System, model 6677400
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0979-2024·2024-02-14

    Barco MDSC-8527 NXF Medical Display decoder functionality blocked

    Barco is recalling MDSC-8527 NXF medical displays due to I2C cable defects in manufacturing that block the MNA decoder functionality. The recall affects a limited batch distributed in New Jersey.

    Product
    Barco MDSC-8527 NXF, Part Number K9352421
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1035-2024·2024-02-14

    BD BBL Moxifloxacin Test Discs Recalled for Susceptibility Testing Inaccuracy

    BD BBL Sensi Disc Moxifloxacin test discs are recalled due to possible failures in antibiotic susceptibility testing accuracy. Test failures could lead to delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Moxifloxacin- 5 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231758¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1008-2024·2024-02-14

    Brasseler dental burs recalled due to defective latching mechanism

    Brasseler USA recalls 440 dental burs due to right angle latch specification failure that prevents proper latching in dental handpieces.

    Product
    Brasseler 8S RA SHP RD (Super-Sharp Round) H1S.21.023, REF 001156T0), carbide dental bur, 10 burs/package, Rx.
    Category
    Medical Device
    Distribution
    Distributed nationwide